극초단파 부분방전 검출장치를 통한 가스절연개폐장치 유지보수 연구

A Study on Maintenance by Ultra High Frequency Partial Discharge Detector for Gas Insulated Switchgear

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류공학일반

초록

Gas insulated switchgear (GIS) was replaced with indoor, compact, and closed-terminal types in accordance with emphasis on maintenance, safety and facilitation. There is a drawback of the long duration in the accident-restoration caused by the impossibility of verification for the fault section within easy range of a technician in the existing GIS facility. Therefore, the partial discharge (PD) measurement techniques were used in the applied voltage state. In this study, the criterion point of PD detector for GIS was obtained by verifying the huge amount of data in the installed and operated systems under Korea Railroad corporation. The criterion point for the judgment on existence/absence of the PD occurrence in GIS was determined with realignment of criterion value through the reflection of the corresponding warning number by detecting pC and PPS values of the ultra high frequency sensor in abnormality and the adjacent sensor. As a result, the scientific and systematic judgment of criterion in the maintenance was secured not only to decrease in economic losses by use-suspension of the operating equipments but also to prevent the accidents by the PD in advance.

Abstract

Gas insulated switchgear (GIS) was replaced with indoor, compact, and closed-terminal types in accordance with emphasis on maintenance, safety and facilitation. There is a drawback of the long duration in the accident-restoration caused by the impossibility of verification for the fault section within easy range of a technician in the existing GIS facility. Therefore, the partial discharge (PD) measurement techniques were used in the applied voltage state. In this study, the criterion point of PD detector for GIS was obtained by verifying the huge amount of data in the installed and operated systems under Korea Railroad corporation. The criterion point for the judgment on existence/absence of the PD occurrence in GIS was determined with realignment of criterion value through the reflection of the corresponding warning number by detecting pC and PPS values of the ultra high frequency sensor in abnormality and the adjacent sensor. As a result, the scientific and systematic judgment of criterion in the maintenance was secured not only to decrease in economic losses by use-suspension of the operating equipments but also to prevent the accidents by the PD in advance.

참고문헌 (5)

  1. Koo Seongeun, , Institute of Electrical Engineers C, 50C(9), pp.450~455 (2001)
  2. 송원표, "가스절연 개폐장치의 내부절연 성능검증을 위한 UHF 협대역 부분방전 진단법", 전기학회논문지 C권, 54(9(C)), pp.414~420 (2005), 대한전기학회
  3. 김원규, "부분방전검출 신뢰도 향상을 위한 UHF 센서개선 및 성능검증", 전기학회논문지, 63(10), pp.1461~1466 (2014), 대한전기학회[DOI]
  4. Kim Yeongno, , World’ electric, 58(2), pp.36~43 (2009)
  5. Choi Gilsu, , Instrumentation Technology, 2013(8), pp.94~101 (2013)

관련 논문AI추천

이 간행물의 다른 논문 (15건)