생물안전 3등급 연구시설 차압 제어 개선 방안에 관한 연구
A Study on Improvement of Differential pressure Control System for Bio-Safety Level 3 Research Facility
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Research to prevent the spread of infectious diseases has become active recently in Korea, and the healthcare industry is growing in importance. Biosafety research facilities require air conditioning equipment that controls the flow of air artificially to prevent infectious agents from leaking out and affecting humans. Two methods for air conditioning systems, the CAV method and the VAV method, are both currently used in biosafety research facilities. In this study, we tried to identify the problems of the two air conditioning control methods and establish a system that can operate safely by generating pressure variables in a laboratory of a biosafety research facility operating the two air conditioning systems. Also a plan for improvements is suggested.
Abstract
Research to prevent the spread of infectious diseases has become active recently in Korea, and the healthcare industry is growing in importance. Biosafety research facilities require air conditioning equipment that controls the flow of air artificially to prevent infectious agents from leaking out and affecting humans. Two methods for air conditioning systems, the CAV method and the VAV method, are both currently used in biosafety research facilities. In this study, we tried to identify the problems of the two air conditioning control methods and establish a system that can operate safely by generating pressure variables in a laboratory of a biosafety research facility operating the two air conditioning systems. Also a plan for improvements is suggested.
참고문헌 (9)
- Ssengooba, W., , Health Research Policy and Systems, 13(4), pp.1~10 (2015)
- Mourya, D. T., , Indian J Med Res., 140(2), pp.171~183 (2014)
- 황지현, "급배기 방식 개선에 따른 생물안전 밀폐시설의 Risk Assessment와 초기 건설비 저감에 대한 연구", 설비공학 논문집, 25(10), pp.534~539 (2013), 대한설비공학회[DOI]
- 홍진관, "생물안전 3등급시설의 공기환경 예측 및 공조부하 절감에 대한 해석", 설비공학 논문집, 24(11), pp.813~822 (2012), 대한설비공학회[DOI]
- 박현진, "생물안전 3등급(BSL3)시설의 생물재해 시나리오에 따른 실내 공기환경예측에 관한 연구", 설비공학 논문집, 22(11), pp.745~750 (2010), 대한설비공학회
- Korea Centers for Disease Control & Prevention, "Laboratory Biosafety Guidelines", ~ (2016)
- Korea Centers for Disease Control & Prevention, "Guideline for establishing and operating a bio-safety Level 3 research facility", ~ (2014)
- Korea Centers for Disease Control & Prevention, "Verification Technical Manual a bio-safety Level 3&4 research facility", ~ (2014)
- World Health Organization, "Laboratory biorisk management: strategic framework for action 2012-2016", ~ (2012)