CFD를 이용한 격리병동의 격리성능 검토
A CFD Simulation Study on the Isolation Performance of a Isolation Ward
0
조회
0
다운로드
7
인용
0
참고문헌
키워드
초록
Purpose: In this study, we performed ventilation simulations for a standard isolation ward includingthree intensive care rooms, one anteroom(buffer room), and its recommended ventilationequipments. The purpose of this study is to predict outflow of pathogenic bacteria from patientbreath to verify the reliability and the safety of the isolation ward. Methods: We suppose threescenarios of the movement of medical staff. The leakage of patient’s breath to out of the ward ispredicted in these scenarios using CFD simulations. Results: The patient’s breath leakage rate to outof the ward in scenario 1 according to room air changes per hour(ACH : 6 and 12) is predictedto be 0.000057% and 0.00002%, respectively. The patient’s breath leakage rate to out of the wardin scenario 2 according to room air changes(ACH : 6 and 12) is predicted to be 0.00063% and0.00019%, respectively. The patient’s breath leakage rate to out of the ward in scenario 3, whichis the worst case(6 room air changes) is predicted to be 0.1%. Implications: Through the ventilationsimulation like that in this study, the reliability and the safety on isolation performance of variousplan of isolation ward are predicted quantitatively.
Abstract
Purpose: In this study, we performed ventilation simulations for a standard isolation ward includingthree intensive care rooms, one anteroom(buffer room), and its recommended ventilationequipments. The purpose of this study is to predict outflow of pathogenic bacteria from patientbreath to verify the reliability and the safety of the isolation ward. Methods: We suppose threescenarios of the movement of medical staff. The leakage of patient’s breath to out of the ward ispredicted in these scenarios using CFD simulations. Results: The patient’s breath leakage rate to outof the ward in scenario 1 according to room air changes per hour(ACH : 6 and 12) is predictedto be 0.000057% and 0.00002%, respectively. The patient’s breath leakage rate to out of the wardin scenario 2 according to room air changes(ACH : 6 and 12) is predicted to be 0.00063% and0.00019%, respectively. The patient’s breath leakage rate to out of the ward in scenario 3, whichis the worst case(6 room air changes) is predicted to be 0.1%. Implications: Through the ventilationsimulation like that in this study, the reliability and the safety on isolation performance of variousplan of isolation ward are predicted quantitatively.
참고문헌 (6)
- 초고층 건축물 건설기술 연구단 최종 보고서(3세부과제: 환경 및 에너지 절감기술), "김진균", ~ (2003)
- 정종림, "종합병원의 환기설비 사례 연구", 한국생태환경건축학회 논문집, 4(3), pp.187~ (2004)
- 질병관리본부, "거점병원 지원 시설기준", ~ (2010)
- 한화택, "난류유동해석을 통한 환기효율의 수치해석적 연구, 공기조화", 냉동공학 논문집, 4(4), pp.253~262 (1992)
- AIA., "Guidelines for Design and Construction of Health Care Facilities", American Institute of Architects, ~ (2006)
- Centers for Disease Control and Prevention, "Guidelines for Environmental Infection Control in Health-Care Facilities", ~ (2003)