Photon dose response functions for accurate skeletal dosimetry for Korean and Asian populations

0

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류원자력공학

초록

To enhance skeletal dosimetry in conjunction with the adult mesh-type reference Korean phantoms (MRKPs), Korean/Asian photon fluence-to-skeletal dose response functions (DRFs) were established utilizing an updated version of micro-CT-based detailed bone models from Tsinghua University. These bone models were incorporated into the MRKPs using the parallel geometry feature of Geant4. We calculated bone-site-specific electron absorbed fractions and used them to generate DRFs, following a similar methodology employed for ICRP-116 DRFs that have been used with the ICRP reference phantoms for skeletal dosimetry. To assess dosimetric implications of the Korean/Asian DRFs, we calculated RBM and BE doses for the MRKPs exposed to photon beams in the antero-posterior direction using the Korean/Asian and ICRP-116 DRFs. For energies ≥200 keV, the Korean/ Asian DRFs-based skeletal doses exhibited excellent agreement with the ICRP-116 DRFs-based skeletal doses, attributed to the existence of charged particle equilibrium across the bone site. Conversely, significant differences of up to ~2.3 times were observed at lower energies, due to differences in the skeletal tissue distributions of bone models used to derive the Korean/Asian and ICRP-116 DRFs. The DRFs established in this study are expected to yield more accurate skeletal doses for Korean and Asian populations compared to the ICRP-116 DRFs.

Abstract

To enhance skeletal dosimetry in conjunction with the adult mesh-type reference Korean phantoms (MRKPs), Korean/Asian photon fluence-to-skeletal dose response functions (DRFs) were established utilizing an updated version of micro-CT-based detailed bone models from Tsinghua University. These bone models were incorporated into the MRKPs using the parallel geometry feature of Geant4. We calculated bone-site-specific electron absorbed fractions and used them to generate DRFs, following a similar methodology employed for ICRP-116 DRFs that have been used with the ICRP reference phantoms for skeletal dosimetry. To assess dosimetric implications of the Korean/Asian DRFs, we calculated RBM and BE doses for the MRKPs exposed to photon beams in the antero-posterior direction using the Korean/Asian and ICRP-116 DRFs. For energies ≥200 keV, the Korean/ Asian DRFs-based skeletal doses exhibited excellent agreement with the ICRP-116 DRFs-based skeletal doses, attributed to the existence of charged particle equilibrium across the bone site. Conversely, significant differences of up to ~2.3 times were observed at lower energies, due to differences in the skeletal tissue distributions of bone models used to derive the Korean/Asian and ICRP-116 DRFs. The DRFs established in this study are expected to yield more accurate skeletal doses for Korean and Asian populations compared to the ICRP-116 DRFs.

참고문헌 (34)

  1. C. Choi, "Mesh-type reference Korean phantoms(MRKPs)for adult male and female for use in radiation protection dosimetry", Phys. Med. Biol, 64, pp.085020~ (2019)
  2. C. H. Kim, "HDRK-Man : a whole-body voxel model based on high-resolution color slice images of a Korean adult male cadaver", Phys. Med. Biol, 53, pp.4093~4106 (2008)
  3. Y. S. Yeom, "HDRK-Woman : whole-body voxel model based on high-resolution color slice images of Korean adult female cadaver", Phys. Med. Biol, 59, pp.3969~3984 (2014)
  4. H. Han, "Development of detailed Korean adult eye model for lens dose calculation", J. Radiat. Prot. Res, 45(1), pp.45~52 (2020)
  5. W. E. Bolch, "Skeletal absorbed fractions for electrons in the adult male : considerations of a revised 50-μm definition of the bone endosteum", Radiat. Protect. Dosim, 127, pp.169~173 (2007)
  6. ICRP, "The 2007 recommendations of the international commission on radiological protection, ICRP publication 103", Ann. ICRP, 37(2–4) (2007)
  7. ICRP, "Adult mesh-type reference computational phantoms, ICRP Publication 145", Ann. ICRP, 49(3) (2020)
  8. ICRP, "Conversion coefficients for radiological protection quantities for external radiation exposures, ICRP Publication 116", Ann. ICRP, 40(2–5) (2010)
  9. ICRP, "The ICRP computational framework for internal dose assessment for reference adults: specific absorbed fractions, ICRP Publication 133", Ann. ICRP, 45(2) (2016)
  10. ICRP, "Dose coefficients for external exposures to environmental sources, ICRP Publication 144", Ann. ICRP, 49(2) (2020)
  11. Y. S. Yeom, "Development of skeletal system for mesh-type ICRP reference adult phantoms", Phys. Med. Biol, 61(19), pp.7054~7073 (2016)
  12. A. A. Bahadori, "Response functions for computing absorbed dose to skeletal tissues from neutron irradiation", Phys. Med. Biol, 56, pp.6873~6897 (2011)
  13. P. B. Johnson, "Response functions for computing absorbed dose to skeletal tissues from photon irradiation–an update", Phys. Med. Biol, 56, pp.2347~2365 (2011)
  14. B. Shin, "New skeletal dose coefficients of the ICRP-110 reference phantoms for idealized external fields to photons and neutrons using dose response functions(DRFs)", Nucl. Eng. Technol, 55, pp.1949~1958 (2023)
  15. M. Hough, "An Image-based skeletal dosimetry model for the ICRP reference adult male–internal electron sources", Phys. Med. Biol, 56, pp.2309~2346 (2011)
  16. S. Gao, "Electron absorbed fractions in an imagebased microscopic skeletal dosimetry model of Chinese adult male", Radiat. Protect. Dosim, 175, pp.450~459 (2017)
  17. C. Choi, "Korean anatomical reference data for adults for use in radiological protection", J. Kor. Phys. Soc, 72, pp.183~191 (2018)
  18. J. Allison, "Recent developments in Geant4", Nucl. Instrum. Methods Phys. Res, 835, pp.186~225 (2016)
  19. Initial MCNP6 Release Overview–MCNP6 Version 1.0, "T. Goorley", Los Alamos National Laboratory, ~, pp.Technical Report LA-UR-13-22934 (2013)
  20. T. Sato, "Particle and heavy ion transport code system, PHITS, version 2.52", J. Nucl. Sci. Technol, 50(9), pp.913~923 (2013)
  21. M. Orok, "Implementation of a Tetrahedral Mesh Phantom Geometry Library for EGSnrc", Doctor, pp.2022
  22. B. Shin, "Incorporation of micro-CT-based detailed bone models into ICRP adult mesh-type reference computational phantoms", Phys. Med. Biol, 67(18), pp.185008~ (2022)
  23. J. Apostolakis, "Parallel geometries in Geant4: foundation and recent enhancements", Proc. Of the IEEE NSS, RTSD Conf, pp.2008[DOI]
  24. Y. S. Yeom, "Tetrahedral-mesh-based computational human phantom for fast Monte Carlo dose calculations", Phys. Med. Biol, 59(12), pp.3173~3185 (2014)
  25. J. Schümann, "Efficient voxel navigation for proton therapy dose calculation in TOPAS and Geant4", Phys. Med. Biol, 57, pp.3281~3293 (2012)
  26. Y. S. Yeom, "Computational speeds and memory requirements of mesh-type ICRP reference computational phantoms in Geant4, MCNP6, and PHITS", Health, Phys, 116, pp.664~676 (2019)
  27. K.F. Eckerman, "Aspects of the Dosimetry of Radionuclides within the Skeleton with Particular Emphasis on the Active Marrow", Proc. 4th Int. Radiopharmaceutical Dosimetry Symp, pp.514~534 (1985), Oak Ridge Associated Universities
  28. "MATLAB Version: 9.14.0 (R2023a)" (2023)[URL]
  29. O. Klein, "Über die Streuung von Strahlung durch freie Elektronen nach der neuen relativistischen Quantendynamik von Dirac", Z. Phys, 52, pp.853~869 (1929)
  30. "Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients (Version 1.4)" (2004)[URL]
  31. S. D. King, "Photoelectron enhancement of the absorbed dose from X rays to human bone marrow : experimental and theoretical studies", Br. J. Radiol, 58, pp.345~356 (1985)
  32. R. Kramer, "All about MAX : a male adult voxel phantom for Monte Carlo calculations in radiation protection dosimetry", Phys. Med. Biol, 38, pp.1239~1262 (2003)
  33. J. Cho, "Derivation of external exposure characteristics of industrial radiography based on empirical evidence", Journal of Radiation Protection and Research, 47(2), pp.93~98 (2022)
  34. C. J. Watchman, "Derivation of site-specific skeletal masses within the current ICRP age series", Phys. Med. Biol, 52, pp.3133~3150 (2007)

관련 논문AI추천

New skeletal dose coefficients of the ICRP-110 reference phantoms for idealized external fields to photons and neutrons using dose response functions (DRFs)신방호, 염연수, 이수민, 이유미, 최지원, 최현준한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제6호Dose coefficients of mesh-type reference Korean phantoms (MRKPs) for idealized external exposure geometries of photons and electrons김수현, 김재효, 김찬형, 김현일, 문성호, 손가희, 신방호, 염연수, 이유민, 정종휘, 최찬수, 한혜진한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제4호Korean-specific iodine S values for use in internal dosimetry정윤선, Kwon Tae-Eun, Lee Choonsik한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제12호Korean-specific dose coefficients for external environmental exposures: Soil contamination신방호, 염연수, 이유미, 최지원, 최찬수한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제10호Dose coefficients for ICRP pediatric mesh-type reference computational phantoms under idealized external electron exposures김찬형, 문성호, 신방호, 염연수, 최찬수, Bolch Wesley E.한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제12호Korean dose coefficients for external exposures from air contamination신방호, 염연수, 이유미, 최지원, 최찬수한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제10호

이 간행물의 다른 논문 (49건)