Photon dose response functions for accurate skeletal dosimetry for Korean and Asian populations
0
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
To enhance skeletal dosimetry in conjunction with the adult mesh-type reference Korean phantoms (MRKPs), Korean/Asian photon fluence-to-skeletal dose response functions (DRFs) were established utilizing an updated version of micro-CT-based detailed bone models from Tsinghua University. These bone models were incorporated into the MRKPs using the parallel geometry feature of Geant4. We calculated bone-site-specific electron absorbed fractions and used them to generate DRFs, following a similar methodology employed for ICRP-116 DRFs that have been used with the ICRP reference phantoms for skeletal dosimetry. To assess dosimetric implications of the Korean/Asian DRFs, we calculated RBM and BE doses for the MRKPs exposed to photon beams in the antero-posterior direction using the Korean/Asian and ICRP-116 DRFs. For energies ≥200 keV, the Korean/ Asian DRFs-based skeletal doses exhibited excellent agreement with the ICRP-116 DRFs-based skeletal doses, attributed to the existence of charged particle equilibrium across the bone site. Conversely, significant differences of up to ~2.3 times were observed at lower energies, due to differences in the skeletal tissue distributions of bone models used to derive the Korean/Asian and ICRP-116 DRFs. The DRFs established in this study are expected to yield more accurate skeletal doses for Korean and Asian populations compared to the ICRP-116 DRFs.
Abstract
To enhance skeletal dosimetry in conjunction with the adult mesh-type reference Korean phantoms (MRKPs), Korean/Asian photon fluence-to-skeletal dose response functions (DRFs) were established utilizing an updated version of micro-CT-based detailed bone models from Tsinghua University. These bone models were incorporated into the MRKPs using the parallel geometry feature of Geant4. We calculated bone-site-specific electron absorbed fractions and used them to generate DRFs, following a similar methodology employed for ICRP-116 DRFs that have been used with the ICRP reference phantoms for skeletal dosimetry. To assess dosimetric implications of the Korean/Asian DRFs, we calculated RBM and BE doses for the MRKPs exposed to photon beams in the antero-posterior direction using the Korean/Asian and ICRP-116 DRFs. For energies ≥200 keV, the Korean/ Asian DRFs-based skeletal doses exhibited excellent agreement with the ICRP-116 DRFs-based skeletal doses, attributed to the existence of charged particle equilibrium across the bone site. Conversely, significant differences of up to ~2.3 times were observed at lower energies, due to differences in the skeletal tissue distributions of bone models used to derive the Korean/Asian and ICRP-116 DRFs. The DRFs established in this study are expected to yield more accurate skeletal doses for Korean and Asian populations compared to the ICRP-116 DRFs.
참고문헌 (34)
- C. Choi, "Mesh-type reference Korean phantoms(MRKPs)for adult male and female for use in radiation protection dosimetry", Phys. Med. Biol, 64, pp.085020~ (2019)
- C. H. Kim, "HDRK-Man : a whole-body voxel model based on high-resolution color slice images of a Korean adult male cadaver", Phys. Med. Biol, 53, pp.4093~4106 (2008)
- Y. S. Yeom, "HDRK-Woman : whole-body voxel model based on high-resolution color slice images of Korean adult female cadaver", Phys. Med. Biol, 59, pp.3969~3984 (2014)
- H. Han, "Development of detailed Korean adult eye model for lens dose calculation", J. Radiat. Prot. Res, 45(1), pp.45~52 (2020)
- W. E. Bolch, "Skeletal absorbed fractions for electrons in the adult male : considerations of a revised 50-μm definition of the bone endosteum", Radiat. Protect. Dosim, 127, pp.169~173 (2007)
- ICRP, "The 2007 recommendations of the international commission on radiological protection, ICRP publication 103", Ann. ICRP, 37(2–4) (2007)
- ICRP, "Adult mesh-type reference computational phantoms, ICRP Publication 145", Ann. ICRP, 49(3) (2020)
- ICRP, "Conversion coefficients for radiological protection quantities for external radiation exposures, ICRP Publication 116", Ann. ICRP, 40(2–5) (2010)
- ICRP, "The ICRP computational framework for internal dose assessment for reference adults: specific absorbed fractions, ICRP Publication 133", Ann. ICRP, 45(2) (2016)
- ICRP, "Dose coefficients for external exposures to environmental sources, ICRP Publication 144", Ann. ICRP, 49(2) (2020)
- Y. S. Yeom, "Development of skeletal system for mesh-type ICRP reference adult phantoms", Phys. Med. Biol, 61(19), pp.7054~7073 (2016)
- A. A. Bahadori, "Response functions for computing absorbed dose to skeletal tissues from neutron irradiation", Phys. Med. Biol, 56, pp.6873~6897 (2011)
- P. B. Johnson, "Response functions for computing absorbed dose to skeletal tissues from photon irradiation–an update", Phys. Med. Biol, 56, pp.2347~2365 (2011)
- B. Shin, "New skeletal dose coefficients of the ICRP-110 reference phantoms for idealized external fields to photons and neutrons using dose response functions(DRFs)", Nucl. Eng. Technol, 55, pp.1949~1958 (2023)
- M. Hough, "An Image-based skeletal dosimetry model for the ICRP reference adult male–internal electron sources", Phys. Med. Biol, 56, pp.2309~2346 (2011)
- S. Gao, "Electron absorbed fractions in an imagebased microscopic skeletal dosimetry model of Chinese adult male", Radiat. Protect. Dosim, 175, pp.450~459 (2017)
- C. Choi, "Korean anatomical reference data for adults for use in radiological protection", J. Kor. Phys. Soc, 72, pp.183~191 (2018)
- J. Allison, "Recent developments in Geant4", Nucl. Instrum. Methods Phys. Res, 835, pp.186~225 (2016)
- Initial MCNP6 Release Overview–MCNP6 Version 1.0, "T. Goorley", Los Alamos National Laboratory, ~, pp.Technical Report LA-UR-13-22934 (2013)
- T. Sato, "Particle and heavy ion transport code system, PHITS, version 2.52", J. Nucl. Sci. Technol, 50(9), pp.913~923 (2013)
- M. Orok, "Implementation of a Tetrahedral Mesh Phantom Geometry Library for EGSnrc", Doctor, pp.2022
- B. Shin, "Incorporation of micro-CT-based detailed bone models into ICRP adult mesh-type reference computational phantoms", Phys. Med. Biol, 67(18), pp.185008~ (2022)
- J. Apostolakis, "Parallel geometries in Geant4: foundation and recent enhancements", Proc. Of the IEEE NSS, RTSD Conf, pp.2008[DOI]
- Y. S. Yeom, "Tetrahedral-mesh-based computational human phantom for fast Monte Carlo dose calculations", Phys. Med. Biol, 59(12), pp.3173~3185 (2014)
- J. Schümann, "Efficient voxel navigation for proton therapy dose calculation in TOPAS and Geant4", Phys. Med. Biol, 57, pp.3281~3293 (2012)
- Y. S. Yeom, "Computational speeds and memory requirements of mesh-type ICRP reference computational phantoms in Geant4, MCNP6, and PHITS", Health, Phys, 116, pp.664~676 (2019)
- K.F. Eckerman, "Aspects of the Dosimetry of Radionuclides within the Skeleton with Particular Emphasis on the Active Marrow", Proc. 4th Int. Radiopharmaceutical Dosimetry Symp, pp.514~534 (1985), Oak Ridge Associated Universities
- "MATLAB Version: 9.14.0 (R2023a)" (2023)[URL]
- O. Klein, "Über die Streuung von Strahlung durch freie Elektronen nach der neuen relativistischen Quantendynamik von Dirac", Z. Phys, 52, pp.853~869 (1929)
- "Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients (Version 1.4)" (2004)[URL]
- S. D. King, "Photoelectron enhancement of the absorbed dose from X rays to human bone marrow : experimental and theoretical studies", Br. J. Radiol, 58, pp.345~356 (1985)
- R. Kramer, "All about MAX : a male adult voxel phantom for Monte Carlo calculations in radiation protection dosimetry", Phys. Med. Biol, 38, pp.1239~1262 (2003)
- J. Cho, "Derivation of external exposure characteristics of industrial radiography based on empirical evidence", Journal of Radiation Protection and Research, 47(2), pp.93~98 (2022)
- C. J. Watchman, "Derivation of site-specific skeletal masses within the current ICRP age series", Phys. Med. Biol, 52, pp.3133~3150 (2007)
