본문 바로가기
KERD
논문KCI 등재

Korean-specific dose coefficients for external environmental exposures: Soil contamination

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류원자력공학

초록

In this study, we first produced the Korean-specific dose coefficients (DCs) for soil contamination using the Meshtype Reference Korean Phantoms (MRKPs). The Korean DCs were compared with the values in ICRP Publication 144 produced using the Caucasian-based ICRP reference phantoms to investigate dosimetric impact due to the racial difference (Korean/Asian vs Caucasian). Monte Carlo dose calculations using the Geant4 code were conducted where the photon and electron sources in the phase-space data used for the ICRP-144 DC calculations were irradiated to the MRKPs. For photons, the organ DCs of the MRKPs showed a good agreement with the ICRP-144 DCs (deviations <20 %) for most energies, while significant differences at energies below 0.05 MeV were observed by up to a factor of 55.6 (thymus at 0.015 MeV). For electrons, notable differences in the organ DCs were observed the overall energy region (deviations >20 % for most cases). The effective DCs of the MRKPs showed an excellent agreement with the ICRP-144 DCs for photons (deviations <16 %), whereas notable differences by up to 1.7 times (0.05 MeV) were observed for electrons. The Korean DCs for soil contamination will be beneficially used in dose estimates for Koreans especially in risk assessments.

Abstract

In this study, we first produced the Korean-specific dose coefficients (DCs) for soil contamination using the Meshtype Reference Korean Phantoms (MRKPs). The Korean DCs were compared with the values in ICRP Publication 144 produced using the Caucasian-based ICRP reference phantoms to investigate dosimetric impact due to the racial difference (Korean/Asian vs Caucasian). Monte Carlo dose calculations using the Geant4 code were conducted where the photon and electron sources in the phase-space data used for the ICRP-144 DC calculations were irradiated to the MRKPs. For photons, the organ DCs of the MRKPs showed a good agreement with the ICRP-144 DCs (deviations <20 %) for most energies, while significant differences at energies below 0.05 MeV were observed by up to a factor of 55.6 (thymus at 0.015 MeV). For electrons, notable differences in the organ DCs were observed the overall energy region (deviations >20 % for most cases). The effective DCs of the MRKPs showed an excellent agreement with the ICRP-144 DCs for photons (deviations <16 %), whereas notable differences by up to 1.7 times (0.05 MeV) were observed for electrons. The Korean DCs for soil contamination will be beneficially used in dose estimates for Koreans especially in risk assessments.

참고문헌 (39)

  1. UNSCEAR 2013 Report Annex A: Levels and Effects of Radiation Exposure Due to the Nuclear Accident after the 2011 Great East-Japan Earthquake and Tsunami, "UNSCEAR", United Nations, ~ (2013)
  2. ICRP, "Dose coefficients for external exposures to environmental sources. ICRP Publication 144" (2020)
  3. ICRP, "Adult reference computational phantoms. ICRP publication 110" (2009)
  4. ICRP, "Paediatric computational reference phantoms. ICRP publication 143" (2020)
  5. ICRP, "Nuclear decay data for dosimetric calculations. ICRP publication 107" (2008)
  6. M. B. Bellamy, "Effective dose rate coefficients for immersions in radioactive air and water", Radiat Prot Dosimetry, 103(1) (2016)[DOI]
  7. K. Saito, "Effective dose conversion coefficients for radionuclides exponentially distributed in the ground", Radiat. Environ. Biophys, 51, pp.411~423 (2012)[DOI]
  8. D. Satoh, "Age-dependent dose conversion coefficients for external exposure to radioactive cesium in soil", J. Nucl. Sci. Technol, 53, pp.69~81 (2016)[DOI]
  9. K. G. Veinot, "Effective dose rate coefficients for exposure to contaminated soil", Radiat. Environ. Biophys, 56, pp.255~267 (2017)[DOI]
  10. S. J. Yoo, "External dose-rate conversion factors of radionuclides for air submersion, ground surface contamination and water immersion based on the new ICRP dosimetric setting", Radiat. Protect. Dosim, 156, pp.7~24 (2013)[DOI]
  11. S. J. Yoo, "Groundshine dose-rate conversion factors of soil contaminated to different depths", Radiat. Protect. Dosim, 157, pp.407~429 (2013)[DOI]
  12. ICRP, "Basic anatomical and physiological data for use in radiological protection reference values, ICRP Publication 89" (2002)
  13. UN, "World Population Prospects: the 2017 Revision", ESA, WP, pp.248, 2017[DOI]
  14. Compilation of Anatomical, Physiological and Metabolic Characteristics for a Reference Asian Man, "IAEA", IAEA, ~, pp.IAEA-TECDOC-1005 (1998)
  15. BICRP, "Report of the Task Group on Reference Man. ICRP Publication, vol. 23" (1975), Pergamon Press
  16. C. Choi, "Korean anatomical reference data for adults for use in radiological protection", J. Kor. Phys. Soc, 72, pp.183~191 (2018)[DOI]
  17. H. M. Cullings, "Body and organ dimensions of the 1945Japanese population used in dosimetry system DS86 and data available for an expanded series of phantoms", Radiat. Protect. Dosim, 149, pp.35~42 (2012)[DOI]
  18. Compilation of Anatomical, Physiological and Metabolic Characteristics for a Reference Vietnamese Man, "Nguyen Manh Lien", IAEA, ~, pp.IAEA-TECDOC–1005(v2) (1998)
  19. Reference Individuals for Use in Radiation Protection Part 2: Masses of Main Organs and Tissues, "Ministry of Health P.R. China", Ministry of Health P.R. China, ~ (2007)
  20. K. Griffin, "Dosimetric impact of a new computational voxel phantom series for the Japanese atomic bomb survivors : children and adults", Radiat. Res, 191(1), pp.369~379 (2019)[DOI]
  21. C. H. Kim, "HDRK-Man : a whole-body voxel model based on high-resolution color slice images of a Korean adult male cadaver", Phys. Med. Biol, 53, pp.4093~ (2008)[DOI]
  22. J. Li, "Organ dose conversion coefficients for external photon irradiation using the Chinese voxel phantom(CVP)", Radiat. Protect. Dosim, 135, pp.33~42 (2009)[DOI]
  23. L. Liu, "Organ dose conversion coefficients on an ICRP-based Chinese adult male voxel model from idealized external photons exposures", Phys. Med. Biol, 54, pp.6645~ (2009)[DOI]
  24. R. Ma, "Development of Chinese meshtype pediatric reference phantom series and application in dose assessment of Chinese undergoing computed tomography scanning", Phys. Med. Biol, 66, pp.195002~ (2021)[DOI]
  25. Y. S. Yeom, "HDRK-Woman : whole-body voxel model based on high-resolution color slice images of Korean adult female cadaver", Phys. Med. Biol, 59, pp.3969~ (2014)[DOI]
  26. G. Zhang, "The development and application of the visible Chinese human model for Monte Carlo dose calculations", Health Phys, 94, pp.118~ (2008)[DOI]
  27. C. Choi, "Mesh-type reference Korean phantoms(MRKPs)for adult male and female for use in radiation protection dosimetry", Phys. Med. Biol, 64, pp.085020~ (2019)[DOI]
  28. J. Allison, "Recent developments in Geant4", Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip, 835, pp.186~225 (2016)[DOI]
  29. M. S. Chung, "Visible Korean human: another trial for making serially sectioned images", Presented at the Medical Imaging 2002, pp.171~183 (2002)
  30. H. Han, "Development of detailed Korean adult eye model for lens dose calculation", J. Radiat. Prot. Res, 45, pp.45~52 (2020)[DOI]
  31. W. Kainz, "Advances in computational human phantoms and their applications in biomedical engineering—a topical review", IEEE Transactions on Radiation and Plasma Medical Sciences, 3, pp.1~23 (2019)[DOI]
  32. T. Sato, "Features of particle and heavy ion transport code system(PHITS)version 3. 02", J. Nucl. Sci. Technol, 55, pp.684~690 (2018)[DOI]
  33. B. Shin, "Photon dose response functions for accurate skeletal dosimetry for Korean and Asian populations", Nucl. Eng. Technol (2024)[DOI]
  34. ICRP, "The 2007 recommendations of the international commission on radiological protection. ICRP publication 103" (2007)
  35. ICRP, "Adult mesh-type reference computational phantoms. ICRP Publication 145" (2020)
  36. Y. S. Yeom, "Conversion of ICRP male reference phantom to polygon-surface phantom", Phys. Med. Biol, 58, pp.6985~ (2013)[DOI]
  37. C. Choi, "Development of paediatric mesh-type reference computational phantom series of International Commission on Radiological Protection", J. Radiol. Prot, 41, pp.S160~ (2021)[DOI]
  38. C. Choi, "Body-sizedependent phantom library constructed from ICRP mesh-type reference computational phantoms", Phys. Med. Biol, 65, pp.125014~ (2020)[DOI]
  39. H. Lee, "Percentile-specific computational phantoms constructed from ICRP mesh-type reference computational phantoms(MRCPs)", Phys. Med. Biol, 64, pp.045005~ (2019)[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (49건)