New skeletal dose coefficients of the ICRP-110 reference phantoms for idealized external fields to photons and neutrons using dose response functions (DRFs)
0
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
The International Commission on Radiological Protection (ICRP) Publication 116 was released to provide a comprehensive dataset of the dose coefficients (DCs) for external exposures produced with the adult reference voxel phantoms of ICRP Publication 110. Although an advanced skeletal dosimetry method for photons and neutrons using fluence-to-dose response functions (DRFs) was introduced in ICRP Publication 116, the ICRP-116 skeletal DCs were calculated by using the simple method conventionally used (i.e., doses to red bone marrow and endosteum approximated by doses to spongiosa and/or medullary cavities). In the present study, the photon and neutron DRFs were used to produce skeletal DCs of the ICRP-110 reference phantoms, which were then compared with the ICRP-116 DCs. For photons, there were significant differences by up to ~2.8 times especially at energies <0.3 MeV. For neutrons, the differences were generally small over the entire energy region (mostly <20%). The general impact of the DRF-based skeletal DCs on the effective dose calculations was negligibly small, supporting the validity of the ICRP-116 effective DCs despite their skeletal DCs derived from the simple method. Meanwhile, we believe that the DRF-based skeletal DCs could be beneficial in better estimates of skeletal doses of individuals for risk assessment
Abstract
The International Commission on Radiological Protection (ICRP) Publication 116 was released to provide a comprehensive dataset of the dose coefficients (DCs) for external exposures produced with the adult reference voxel phantoms of ICRP Publication 110. Although an advanced skeletal dosimetry method for photons and neutrons using fluence-to-dose response functions (DRFs) was introduced in ICRP Publication 116, the ICRP-116 skeletal DCs were calculated by using the simple method conventionally used (i.e., doses to red bone marrow and endosteum approximated by doses to spongiosa and/or medullary cavities). In the present study, the photon and neutron DRFs were used to produce skeletal DCs of the ICRP-110 reference phantoms, which were then compared with the ICRP-116 DCs. For photons, there were significant differences by up to ~2.8 times especially at energies <0.3 MeV. For neutrons, the differences were generally small over the entire energy region (mostly <20%). The general impact of the DRF-based skeletal DCs on the effective dose calculations was negligibly small, supporting the validity of the ICRP-116 effective DCs despite their skeletal DCs derived from the simple method. Meanwhile, we believe that the DRF-based skeletal DCs could be beneficial in better estimates of skeletal doses of individuals for risk assessment
참고문헌 (15)
- ICRP, "Conversion Coefficients for Radiological Protection Quantities for External Radiation Exposures", ann, ICRP, 40 (2010), ICRP
- ICRP, "The 2007 recommendations of the international commission on radiological protection", Ann. ICRP, 37 (2007), ICRP
- ICRP, "Conversion coefficients for use in radiological protection against external radiation", Ann. ICRP, 26 (1996), ICRP
- ICRP, "Recommendations of the international commission on radiological protection", Ann. ICRP, 21 (1991), ICRP
- ICRP, "Adult reference computational phantoms", Ann. ICRP, 39 (2009), ICRP
- ICRP, "Basic anatomical and physiological data for use in radiological protection:reference values", Ann. ICRP, 32 (2002), ICRP
- The ORNL Mathematical Phantom Series, "K. F. Eckerman", Oak Ridge National Laboratory, ~ (1996)
- P. B. Johnson, "Response functions for computing absorbed dose to skeletal tissues from photon irradiation-an update", Phys. Med. Biol, 56, pp.2347~2365 (2011)
- A. A. Bahadori, "Response functions for computing absorbed dose to skeletal tissues from neutron irradiation", Phys. Med. Biol, 56, pp.6873~6897 (2011)
- M. Zankl, "The adult male voxel model"Golem"segmented from whole-body CT patient data", Radiat. Environ. Biophys, 40, pp.153~162 (2001)
- K.F. Eckerman, "Aspects of the dosimetry of radionuclides within the skeleton with particular emphasis on the active marrow", Proc. 4th Int. Radiopharmaceutical Dosimetry Symp. Ed A T Schlafke-Stelson and E E Watson, pp.514~534 (1985), Oak Ridge Associated Universities
- T. Goorley, "Initial MCNP6 release overview", Nucl. Technol, 180, pp.298~315 (2012)
- T. Goorley, "Features of MCNP6", Ann. Nucl. Energy, 87, pp.772~783 (2016)
- The EGSnrc Code System: Monte Carlo Simulation of Electron and Photon Transport, "I. Kawrakow", National Research Council of Canada, ~, pp.NRCC Report PIRS-701 (2009)
- H. Iwase, "Development of a general-purpose particle and heavy ion transport Monte Carlo code", J. Nucl. Sci. Technol, 39, pp.1142~1151 (2002)
