Two-dimensional distribution reconstruction and emittance diagnostics of proton beam phase space using tomography

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류원자력공학

초록

A two-dimensional distribution of a proton beam in phase space was reconstructed using beam profile data and a tomography technique in this study. These beam profile data were acquired by a wire scanner under various beam optics conditions, employing an experimental procedure identical, in principle, to the quadrupole magnet (QM) scan method to diagnose beam parameters. According to beam optics, beam profile data measured while changing the QM current is the same as that measured while rotating the beam distribution in the phase space. Thus, the set of the beam profile data can be converted into a sinogram, serving as source data for tomography. A filtered-back-projection (FBP) method is applied to reconstruct the beam distribution from this sinogram. However, if the range and distribution of the rotation angle are not sufficient, the reconstructed distribution data will be inaccurate, which will negatively affect beam parameter evaluation. To solve this limitation, a simulator incorporating the beam optics theory with the tomography was developed to derive an efficient experimental condition. The beam distribution in the phase space was successfully reconstructed, and the beam parameters evaluated from this were also confirmed to match well with the values obtained from the QM scan.

Abstract

A two-dimensional distribution of a proton beam in phase space was reconstructed using beam profile data and a tomography technique in this study. These beam profile data were acquired by a wire scanner under various beam optics conditions, employing an experimental procedure identical, in principle, to the quadrupole magnet (QM) scan method to diagnose beam parameters. According to beam optics, beam profile data measured while changing the QM current is the same as that measured while rotating the beam distribution in the phase space. Thus, the set of the beam profile data can be converted into a sinogram, serving as source data for tomography. A filtered-back-projection (FBP) method is applied to reconstruct the beam distribution from this sinogram. However, if the range and distribution of the rotation angle are not sufficient, the reconstructed distribution data will be inaccurate, which will negatively affect beam parameter evaluation. To solve this limitation, a simulator incorporating the beam optics theory with the tomography was developed to derive an efficient experimental condition. The beam distribution in the phase space was successfully reconstructed, and the beam parameters evaluated from this were also confirmed to match well with the values obtained from the QM scan.

참고문헌 (14)

  1. P. Strehl, "Beam Instrumentation and Diagnostics", pp.215~262 (2006), Springer
  2. Eduard Prat, "Symmetric single-quadrupole-magnet scan method to measure the 2D transverse beam parameters", Nucl. Instrum. Methods Phys. Res, 743, pp.103~108 (2014)
  3. M. Yan, "Comparison of quadrupole scan and multi-screen method for the measurement of projected and slice emittance at the swissFEL injector test facility", Proc. FEL, 14, pp.941~944 (2014)
  4. M. E. Schulze, "Characterization of the proton beam from the 6.7 MeV LEDA RFQ", Proc. PAC01, pp.591~593 (2001)
  5. W. M. Tam, "Fermilab HINS proton ion source beam measurements", Proc. PAC09, pp.3570~3572 (2009)
  6. C. Limborg, "A modified QuadScan technique for emittance measurement of space charge dominated beams", Proc. PAC03, pp.2667~2669 (2003)
  7. D. Stratakis, "Tomography as a diagnostic tool for phase space mapping of intense particle beams", Phys. Rev. Spec. Top. Accel. Beams, 9, pp.112801~ (2006)
  8. J. Hsieh, "Computed Tomography Principles, Design, Artifacts, and Recent Advances" (2009), SPIE
  9. F. Natterer, "The Mathematics of Computerized Tomography" (2001), SIAM
  10. K. M. Hock, "Beam tomography in transverse normalized phase space", Nucl. Instrum. Methods A, 642, pp.36~44 (2011)
  11. S. Zheng, "Maximum entropy tomography reconstruction", Proceedings of ICAP2015, pp.55~57 (2015)
  12. P. A. P. Nghiem, "Using of the MENT method for reconstruction of 2D particle distributions in IFMIF accelerators", Proc. IPAC16, pp.668~670 (2016)
  13. Han-Sung Kim, "Operational status of and upgrade plan for the 100-MeV proton linac at the Korea multi-purpose accelerator complex", J. Kor. Phys. Soc, 80, pp.799~807 (2022)
  14. H. Wiedemann, "Particle Accelerator Physics", pp.222~227 (2015), Springer