True coincidence summing correction factor for point source geometry with PHITS

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류원자력공학

초록

In this study, it has been shown that the true coincidence summing correction factor can be obtained for the first time using the PHITS Monte Carlo program. Determining this correction factor using different methods and tools in each laboratory to increase the possibility of achieving high-efficiency measurement conditions is still popular in gamma-ray spectrometry. By using 133Ba, 152Eu, 134Cs, and 60Co point sources, the true coincidence summing factor was investigated in both near and far counting geometries for 15 different energy values. GESPECOR software was used to validate the results obtained with PHITS. A remarkable agreement was obtained between PHITS and GESPECOR, with a discrepancy of less than 3%. With this study, a new tool has been proposed to obtain the true coincidence summing factor, which is one of the significant correction factors investigated/ calculated in gamma-ray spectrometric studies

Abstract

In this study, it has been shown that the true coincidence summing correction factor can be obtained for the first time using the PHITS Monte Carlo program. Determining this correction factor using different methods and tools in each laboratory to increase the possibility of achieving high-efficiency measurement conditions is still popular in gamma-ray spectrometry. By using 133Ba, 152Eu, 134Cs, and 60Co point sources, the true coincidence summing factor was investigated in both near and far counting geometries for 15 different energy values. GESPECOR software was used to validate the results obtained with PHITS. A remarkable agreement was obtained between PHITS and GESPECOR, with a discrepancy of less than 3%. With this study, a new tool has been proposed to obtain the true coincidence summing factor, which is one of the significant correction factors investigated/ calculated in gamma-ray spectrometric studies

참고문헌 (24)

  1. J. Knezevic, "Corrections of HPGe detector efficiency curve due to true coincidence summing by program EFFTRAN and by Monte Carlo simulations", Applied Radiation and Isotopes, 189, pp.110421~ (2022), Elsevier BV[DOI]
  2. 이지은, "Source and LVis based coincidence summing correction in HPGe gamma-ray spectrometry", Nuclear Engineering and Technology, 54(5), pp.1754~1759 (2022), 한국원자력학회[DOI]
  3. Octavian Sima, "Efficiency calculation of gamma detectors by Monte Carlo methods", Encyclopedia of Analytical Chemistry (2012), Wiley[DOI]
  4. Dušan Novković, "Coincidence summing of X- and γ-rays in γ-ray spectrometry", Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 578(1), pp.207~217 (2007), Elsevier BV[DOI]
  5. J.G. Guerra, "Modeling of a HPGe well detector using PENELOPE for the calculation of full energy peak efficiencies for environmental samples", Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 908, pp.206~214 (2018), Elsevier BV[DOI]
  6. O. Sima, "Consistency test of coincidence-summing calculation methods for extended sources", Applied Radiation and Isotopes, 155, pp.108921~ (2020), Elsevier BV[DOI]
  7. M.-C. Lépy, "Intercomparison of methods for coincidence summing corrections in gamma-ray spectrometry", Applied Radiation and Isotopes, 68(7-8), pp.1407~1412 (2010), Elsevier BV[DOI]
  8. M.-C. Lépy, "Intercomparison of methods for coincidence summing corrections in gamma-ray spectrometry—part II (volume sources)", Applied Radiation and Isotopes, 70(9), pp.2112~2118 (2012), Elsevier BV[DOI]
  9. François Piton, "Efficiency transfer and coincidence summing corrections for γ-ray spectrometry", Applied Radiation and Isotopes, 52(3), pp.791~795 (2000), Elsevier BV[DOI]
  10. Marie-Christine Lépy, "Experimental validation of coincidence summing corrections computed by the ETNA software", Applied Radiation and Isotopes, 64(10-11), pp.1340~1345 (2006), Elsevier BV[DOI]
  11. Octavian Sima, "Accurate computation of coincidence summing corrections in low level gamma-ray spectrometry", Applied Radiation and Isotopes, 53(1-2), pp.51~56 (2000), Elsevier BV[DOI]
  12. O. Sima, "GESPECOR: a versatile tool in gamma-ray spectrometry", Journal of Radioanalytical and Nuclear Chemistry, 248(2), pp.359~364 (2001), Springer Science and Business Media LLC[DOI]
  13. Dirk Arnold, "Calculation of coincidence summing corrections for X-ray peaks and for sum peaks with X-ray contributions", Applied Radiation and Isotopes, 64(10-11), pp.1297~1302 (2006), Elsevier BV[DOI]
  14. Octavian Sima, "A tool for processing decay scheme data that encompasses coincidence summing calculations", Applied Radiation and Isotopes, 66(6-7), pp.705~710 (2008), Elsevier BV[DOI]
  15. 윤은택, "Coincidence summing correction for a voluminous 152Eu source", Nuclear Engineering and Technology, 52(6), pp.1266~1270 (2020), 한국원자력학회[DOI]
  16. “TRUECOINC”, A software utility for calculation of the true coincidence correction, "S. Sudar", IAEA, 37~48, pp.Tecdoc 1275 (2002)
  17. J. Ordóñez, "Coincidence summing correction factors for 238U and 232Th decay series using the Monte Carlo method", Radiation Physics and Chemistry, 155, pp.244~247 (2019), Elsevier BV[DOI]
  18. H. Yücel, "True coincidence-summing corrections for the coincident γ-rays measured with coplanar grid CdZnTe detectors", Applied Radiation and Isotopes, 68(6), pp.1040~1048 (2010), Elsevier BV[DOI]
  19. G.F. Knoll, "Radiation Detection and Measurement" (2010), John Wiley & Sons, Inc
  20. M.H. Bölükdemir, "Investigation of shape effects and dead layer thicknesses of a coaxial HPGe crystal on detector efficiency by using PHITS Monte Carlo simulation", Radiation Physics and Chemistry, 189, pp.109746~ (2021), Elsevier BV[DOI]
  21. "GammaVision, Gamma-Ray Spectrum Analysis and MCA Emulation for; Software User’s Manual; Version 32; V5.10", ~
  22. Tatsuhiko Sato, "Features of Particle and Heavy Ion Transport code System (PHITS) version 3.02", Journal of Nuclear Science and Technology, 55(6), pp.684~690 (2018), Informa UK Limited[DOI]
  23. Octavian Sima, "On the Monte Carlo simulation of HPGe gamma-spectrometry systems", Applied Radiation and Isotopes, 67(5), pp.701~705 (2009), Elsevier BV[DOI]
  24. "Decay Data Evaluation Project-Recommended Data" (2023)[URL]

관련 논문AI추천

이 간행물의 다른 논문 (39건)