Development of a dual-mode energy-resolved neutron imaging detector: High spatial resolution and large field of view
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Energy-resolved neutron imaging is an effective way to investigate the internal structure and residual stress of materials. Different sample sizes have varying requirements for the detector’s imaging field of view (FOV) and spatial resolution. Therefore, a dual-mode energy-resolved neutron imaging detector was developed, which mainly consisted of a neutron scintillator screen, a mirror, imaging lenses, and a time-stamping optical fast camera. This detector could operate in a large FOV mode or a high spatial resolution mode. To evaluate the performance of the detector, the neutron wavelength spectra and the multiple spatial resolution tests were conducted at CSNS. The results demonstrated that the detector accurately measured the neutron wavelength spectra selected by a bandwidth chopper. The best spatial resolution was about 20 μm in high spatial resolution mode after event reconstruction, and a FOV of 45.0 mm × 45.0 mm was obtained in large FOV mode. The feasibility was validated to change the spatial resolution and FOV by replacing the scintillator screen and adjusting the lens magnification.
Abstract
Energy-resolved neutron imaging is an effective way to investigate the internal structure and residual stress of materials. Different sample sizes have varying requirements for the detector’s imaging field of view (FOV) and spatial resolution. Therefore, a dual-mode energy-resolved neutron imaging detector was developed, which mainly consisted of a neutron scintillator screen, a mirror, imaging lenses, and a time-stamping optical fast camera. This detector could operate in a large FOV mode or a high spatial resolution mode. To evaluate the performance of the detector, the neutron wavelength spectra and the multiple spatial resolution tests were conducted at CSNS. The results demonstrated that the detector accurately measured the neutron wavelength spectra selected by a bandwidth chopper. The best spatial resolution was about 20 μm in high spatial resolution mode after event reconstruction, and a FOV of 45.0 mm × 45.0 mm was obtained in large FOV mode. The feasibility was validated to change the spatial resolution and FOV by replacing the scintillator screen and adjusting the lens magnification.
참고문헌 (18)
- W. Kockelmann, "Energyselective neutron transmission imaging at a pulsed source", Nucl. Instrum. Methods A, 578, pp.421~434 (2007)
- L. Josic, "Energy selective neutron imaging in solid state materials science", Nucl. Instrum. Methods A, 651, pp.166~170 (2011)
- Y. Su, "Neutron Bragg-Edge Transmission Imaging for Microstructure and Residual Strain in Induction Hardened Gears", Scientific Reports, pp.11~ (2021), Nature Publisher Group
- I. Dhiman, "Setup for polarized neutron imaging using in situ 3He cells at the Oak ridge national Laboratory high Flux Isotope Reactor CG-1D beamline", Rev. Sci. Instrum, 88 (2017)
- X. Llopart, "Timepix, a 65k programmable pixel readout chip for arrival time, energy and", or photon counting measurements, 2007, pp.581, 485~494
- W. Kockelmann, "Time-ofFlight neutron imaging on imat@ISIS: a new user facility for materials science", J. Imaging, 4 (2018)
- T. Shinohara, "The energy-resolved neutron imaging system, RADEN", Rev. Sci. Instrum., 91 (2020)
- P. Trtik, "PSI ‘neutron microscope’at ILL-D50 beamline—first results", Mater. Res. Proc, pp.23~28 (2020)
- A. Tengattini, "Compact and versatile neutron imaging detector with sub-4μm spatial resolution based on a single-crystal thinfilm scintillator", Opt Express, 30, pp.14461~14477 (2022)
- D. S. Hussey, "Neutron imaging detector with 2 μm spatial resolution based on event reconstruction of neutron capture in gadolinium oxysulfide scintillators", Nucl. Instrum. Methods Phys. Res., Sect. A, 866, pp.9~12 (2017)
- J. Yang, "A novel energy resolved neutron imaging detector based on a time stamping optical camera for the CSNS", Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip, 1000, pp.165222~ (2021)
- A. S. Losko, "New perspectives for neutron imaging through advanced event-mode data acquisition", Sci. Rep, 11, pp.21360~ (2021)
- P. Trtik, "Improving the spatial resolution of neutron imaging at Paul scherrer institut – the neutron microscope project", Phys. Procedia, 69, pp.169~176 (2015)
- X. Jiang, "Study on the Neutron Imaging Detector with High Spatial Resolution at China Spallation Neutron Source", Nucl Eng Technol (2020)
- C. Wu, "A study of ZnS(Ag)", 6LiF with different mass ratios, 2013, pp.58, 128~132
- M. Hildebrandt, "Evaluation of ZnS : (LiF)-Li-6 and ZnO : (LiF)-Li-6 scintillation neutron detectors readout with SiPMs", IEEE Trans. Nucl. Sci, 65, pp.2061~2067 (2018)
- C. Grunzweig, "Highly absorbing gadolinium test device to characterize the performance of neutron imaging detector systems", Rev. Sci. Instrum, 78, pp.053708~ (2007)
- M. Harada, "Experimental validation of the brightness distribution on the surfaces of coupled and decoupled moderators composed of 99. 8%parahydrogen at the J-PARC pulsed spallation neutron source", Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip, 903, pp.38~45 (2018)
