Time-encoded imagers (TEI) are important class of instruments to search for potential radioactive sources to prevent illicit transportation and trafficking of nuclear materials and other radioactive sources. The energy of the radiation cannot be known in advance due to the type and shielding of source is unknown in practice. However, the response function of the time-encoded imagers is related to the energy of neutrons or gamma-rays. An improved image reconstruction method based on MLEM was proposed to correct for the energy induced response difference. In this method, the count vector versus time was first smoothed. Then, the preset response function was adaptively corrected according to the measured counts. Finally, the smoothed count vector and corrected response were used in MLEM to reconstruct the source distribution. A one-dimensional dual-particle time-encode imager was developed and used to verify the improved method through imaging an AmeBe neutron source. The improvement of this method was demonstrated by the image reconstruction results. For gamma-ray and neutron images, the angular resolution improved by 17.2% and 7.0%; the contrast-to-noise ratio improved by 58.7% and 14.9%; the signal-to-noise ratio improved by 36.3% and 11.7%, respectively.
Abstract
Time-encoded imagers (TEI) are important class of instruments to search for potential radioactive sources to prevent illicit transportation and trafficking of nuclear materials and other radioactive sources. The energy of the radiation cannot be known in advance due to the type and shielding of source is unknown in practice. However, the response function of the time-encoded imagers is related to the energy of neutrons or gamma-rays. An improved image reconstruction method based on MLEM was proposed to correct for the energy induced response difference. In this method, the count vector versus time was first smoothed. Then, the preset response function was adaptively corrected according to the measured counts. Finally, the smoothed count vector and corrected response were used in MLEM to reconstruct the source distribution. A one-dimensional dual-particle time-encode imager was developed and used to verify the improved method through imaging an AmeBe neutron source. The improvement of this method was demonstrated by the image reconstruction results. For gamma-ray and neutron images, the angular resolution improved by 17.2% and 7.0%; the contrast-to-noise ratio improved by 58.7% and 14.9%; the signal-to-noise ratio improved by 36.3% and 11.7%, respectively.
참고문헌 (18)
- H. Al Hamrashdi, "Passive gamma-ray and neutron imaging systems for national security and nuclear non-proliferation in controlled and uncontrolled detection areas : review of past and current status", Sensors, 19, pp.2638~ (2019)
- R. C. Runkle, "Neutron sensors and their role in nuclear nonproliferation", Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip, 652, pp.37~40 (2011)
- R. C. Runkle, "Securing special nuclear material : recent advances in neutron detection and their role in nonproliferation", J. Appl. Phys, 108, pp.13~ (2010)
- A. Glick, "Deployment of a double scatter system for directional detection of background neutron radiation", Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip, 992, pp.165029~ (2021)
- A. Poitrasson-Riviere, "Dual-particle imaging system based on simultaneous detection of photon and neutron collision events", Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip, 760, pp.40~45 (2014)
- R. S. Woolf, "Fast-neutron, coded-aperture imager", Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip, 784, pp.398~404 (2015)
- "The deployable fast-neutron coded-aperture imager: demonstration of locating one or more sources in three dimensions" (2013)[URL]
- N. P. Shah, "Improved localization precision and angular resolution of a cylindrical, time-encoded imaging system from adaptive detector movements", IEEE Trans. Nucl. Sci, 68, pp.410~425 (2021)
- J. Mueller, "Passive one-dimensional self-transmission imaging of subcritical metallic plutonium assemblies", Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip, 903, pp.277~286 (2018)
- N. Shah, "Adaptive Imaging with a Cylindrical, Time-Encoded Imaging System" (2020)
- N. P. Shah, "Design and construction of a 1-D, cylindrical, dual-particle, time-encoded imaging system", Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip, 954, pp.161785~ (2020)
- A. Barzilov, "Time encoded imaging of neutrons and photons using CLYC detector equipped with a dual mode collimator", Sensors & Transducers, 229, pp.78~83 (2019)
- J. Brennan, "Demonstration of two-dimensional timeencoded imaging of fast neutrons", Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip, 802, pp.76~81 (2015)
- X. Liang, "Self-supporting design of a time-encoded aperture, gamma-neutron imaging system", Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip, 951, pp.162964~ (2020)
- J. Brennan, "Source detection at 100 meter standoff with a time-encoded imaging system", Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip, 877, pp.375~383 (2018)
- B. Kowash, "A unified near-and far-field imaging model for rotating modulation collimators", Nucl. Instrum. Methods Phys. Res. Sect. A Accel. Spectrom. Detect. Assoc. Equip, 637, pp.178~184 (2011)
- P. Marleau, "Time encoded fast neutron", gamma imager for large standoff SNM detection, 2011 (2011), 591~595[DOI]
- R. J. Olesen, "Maximum likelihood reconstructions for rotating scatter mask imaging", Radiat. Meas, 137, pp.106441~ (2020)