본문 바로가기
KERD
논문KCI 등재

Fission counter array for pulse-mode measurements of high-flux and high-energy neutrons

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류원자력공학

초록

This manuscript describes a neutron counting system based on cylindrical fission counters that can monitor neutron activity for high-energy neutron flux above 10 MeV under electrically noisy environments with intense gamma rays. Miniature fission counters with depleted uranium as sensitive material and modular electronics were built for digital signal processing and high-countrate operation. The counters are 9.5 mm in diameter and 71.1 mm in active length. The author presents the results of Monte Carlo simulations of the fission-counter response for selected neutron sources and energies based on ENDF7.1, JENDL-5, and TENDL-2021 nuclear data libraries from 1 meV to 200 MeV. For a white neutron beam (E = 16.36 MeV) that irradiates the front face of a counter, the intrinsic efficiency is evaluated to be (2.24 ± 0.02) × 10􀀀 5 counts/n, while the efficiency of the counter in the array appears to increase by at most 6.7%.

Abstract

This manuscript describes a neutron counting system based on cylindrical fission counters that can monitor neutron activity for high-energy neutron flux above 10 MeV under electrically noisy environments with intense gamma rays. Miniature fission counters with depleted uranium as sensitive material and modular electronics were built for digital signal processing and high-countrate operation. The counters are 9.5 mm in diameter and 71.1 mm in active length. The author presents the results of Monte Carlo simulations of the fission-counter response for selected neutron sources and energies based on ENDF7.1, JENDL-5, and TENDL-2021 nuclear data libraries from 1 meV to 200 MeV. For a white neutron beam (E = 16.36 MeV) that irradiates the front face of a counter, the intrinsic efficiency is evaluated to be (2.24 ± 0.02) × 10􀀀 5 counts/n, while the efficiency of the counter in the array appears to increase by at most 6.7%.

참고문헌 (16)

  1. G. D. Hickman, "A miniature fast fission counter", Nucl. Instrum. Methods, 13, pp.190~196 (1961)
  2. M. T. Swinhoe, "Calculation and measurement of 235U and 238U fission counter assembly detection efficiency", Nucl. Instrum. Methods Phys. Res, 221, pp.460~465 (1984)
  3. M. Fadil, "Development of fission micro-chambers for nuclear waste incineration studies", Nucl. Instrum. Methods Phys. Res, 476, pp.313~317 (2002)
  4. Zs Elter, "Performance investigation of the pulse and Campbelling modes of a fission chamber using a Poisson pulse train simulation code", Nucl. Instrum. Methods Phys. Res, 774, pp.60~67 (2015)
  5. P. Lee, "Characterization study of fast neutron sources based on proton accelerators at KOMAC", J. Phys. Conf, 1350, pp.012066~ (2019)
  6. P. G. Young, "Evaluation of neutron Reactions for ENDF", B-VII : 232-241U and 239Pu, 2007, pp.108(12), 2589~2654
  7. O. Iwamoto, "Japanese evaluated nuclear data library version 5 : JENDL-5", J. Nucl. Sci. Technol, 60(1), pp.1~60 (2023)
  8. A. J. Koning, "TENDL : complete nuclear data library for innovative nuclear science and technology", Nucl. Data Sheets, 155, pp.1~55 (2019)
  9. S. Agostinelli, "GEANT4-a simulation toolkit", Nucl. Instrum. Methods Phys. Res., Sect. A, 506, pp.250~303 (2003)
  10. J. Allison, "Geant4developments and applications", IEEE Trans. Nucl. Sci, 53, pp.270~278 (2006)
  11. J. Allison, "Recent developments in GEANT4", Nucl. Instrum. Methods Phys. Res, 835, pp.186~225 (2016)
  12. S.F. Naeem, "Comparison of GEANT4 and MCNPX-PoliMi fission models", Proceedings of IEEE Nuclear Science Symposium
  13. J. Tan, "Geant4 modifications for accurate fission simulations", Phys. Procedia, 90, pp.256~265 (2017)
  14. K. S. Krane, "Introductory Nuclear Physics" (1987), John Wiley&Sons
  15. I. V. Ryzhov, "Fragmentmass distributions in neutron-induced fission of 232Th and 238U at 33, 45, and 60MeV", Phys. Rev. C, 83, pp.054603~ (2011)
  16. International Organization for Standardization, "Reference Neutron Radiations -Part 1:Characteristics and Methods of Production", ISO Standard No. 8529-1:2001, ~ (2001)

관련 논문AI추천

Determination of the number of 235U target nuclei in the irregular target using a fission time projection chamberPeng Taiping, Sun Junjie, Xiao Jun, Zhang Jiajun, Zhang Mingzhi, Zheng Pu한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제2호Monte Carlo simulation of an accounting system for small amounts of special nuclear material using fast neutron multiplicity counting고찬규, 정만희한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제6호A novel embedded spherical semiconductor neutron detector efficiency estimation using GEANT4 simulation methodologyKumar Vikas, Nayak Avinash, Parida Manoj Kumar한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제3호Differential die-away technology applied to detect special nuclear materialsLiu Chao, Li Yong, Tang Mengjiao, Wang Guobao, Wang Qiang, Zhang Chen, Zhang Lianjun, Zheng Yulai한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제7호원전 내 사용후핵연료 연소도 측정을 위한 중성자 검출기의 성능 평가 연구김태영, 박혜민, 송양수, 이운장, 이인호, 장대헌, 함철민(사)한국방사선산업학회 · 방사선산업학회지2023 · 제17권 제3호Neutron/gamma scintillation detector for status monitoring of accelerator-driven neutron source IRENAhmadov F., Ahmadov G., Akbarov R., Berikov D., Holik M., Madadzada A., Naghiyev J., Nuruyev S., Sadigov A., Udovichenko K.한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제5호

이 간행물의 다른 논문 (49건)