본문 바로가기
KERD
논문KCI 등재

Neutron/gamma scintillation detector for status monitoring of accelerator-driven neutron source IREN

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류원자력공학

초록

This paper presents a neutron/gamma detector based on a micropixel avalanche photodiode and a plastic scintillator that monitors the status of the accelerator-driven intense resonance neutron source (IREN) facility by measuring the neutron/gamma intensity in the target hall. The electronics of the neutron/gamma detector has been designed and developed. The size of the plastic scintillator was selected to be 3.7 × 3.7 × 30 mm3 due to the sensitive area of the MAPD. The experimental results demonstrated a dependence between the count rate of the detector and the frequency of the accelerator. The detector is sensitive to intermediate and fast neutrons. The minimum detectable energy was determined to be 200 keV using Cs-137 point gamma source. The maximum counting rate of the detector from TTL out is about 2.2⋅106 counts/sec, but for analogue output it is about 2⋅107 counts/sec. The detector can not allow discriminating neutrons and gamma rays by charge integration method.

Abstract

This paper presents a neutron/gamma detector based on a micropixel avalanche photodiode and a plastic scintillator that monitors the status of the accelerator-driven intense resonance neutron source (IREN) facility by measuring the neutron/gamma intensity in the target hall. The electronics of the neutron/gamma detector has been designed and developed. The size of the plastic scintillator was selected to be 3.7 × 3.7 × 30 mm3 due to the sensitive area of the MAPD. The experimental results demonstrated a dependence between the count rate of the detector and the frequency of the accelerator. The detector is sensitive to intermediate and fast neutrons. The minimum detectable energy was determined to be 200 keV using Cs-137 point gamma source. The maximum counting rate of the detector from TTL out is about 2.2⋅106 counts/sec, but for analogue output it is about 2⋅107 counts/sec. The detector can not allow discriminating neutrons and gamma rays by charge integration method.

참고문헌 (27)

  1. Yoshiaki Kiyanagi, "Neutron imaging at compact accelerator-DrivenNeutron sources in Japan", J. Imag, 4, pp.55~ (2018)[DOI]
  2. R. J. W. Frost, "A compact accelerator driven neutron source at the Applied Nuclear Physics Laboratory", Lund Univ. EPJ Techniq. Instrument, 10, pp.14~ (2023)[DOI]
  3. Jungbae Bahng, "Design of compact accelerator system for high flux accelerator based neutron source", Rev. Sci. Instrum, 91, pp.023323~ (2020)[DOI]
  4. V. N. Shvetsov, "Neutron sources at the frank laboratory of neutron physics of the joint institute for nuclear research", Quant. Beam Sci, 1, pp.6~ (2017)[DOI]
  5. J. Boettcher, "LUE-200 accelerator of IREN facility : current status and development", Phys. Part. Nucl. Lett, 11, pp.665~ (2014)[DOI]
  6. V. Anan’ev, "Intense resonance neutron source(IREN)– new pulsed source for nuclear physical and applied investigations", Phys. Part. Nucl. Lett, 2, pp.11~ (2005)
  7. R. Akbarov, "Fast neutron detectors with silicon photomultiplier readouts", Nucl. Instrum. Methods Phys. Res, 936, pp.549~ (2019)[DOI]
  8. G. Ahmadov, "Gamma-ray spectroscopy with MAPD array in the readout of LaBr3 : Ce scintillator", J. Inst. Met, 16, pp.P07020~ (2021)[DOI]
  9. R. A. Akbarov, "Scintillation readout with MAPD array for gamma spectrometer", J. Inst. Met, 15, pp.C01001~ (2020)[DOI]
  10. F. Ahmadov, "New gamma detector modules based on micropixel avalanche photodiode", J. Inst. Met, 12, pp.C01003~ (2007)[DOI]
  11. V. Regazzoni, "Characterization of high density SiPM non-linearity and energy resolution for prompt gamma imaging applications", J. Inst. Met, 12, pp.P07001~ (2017)[DOI]
  12. Dennis R. Schaart, "Physics and technology of time-of-flight PET detectors", Phys. Med. Biol, 66, pp.09~ (2021)[DOI]
  13. Virginia Ch Spanoudaki, "Photo-detectors for time of flight positron emission tomography(ToF-PET)", Sensors, 10, pp.10484~ (2010)[DOI]
  14. M. Ablikim, "Search for the charged lepton flavor violating decay J= ! eτ", Phys. Rev. D, 103, pp.112007~ (2021)[DOI]
  15. F. Ahmadov, "Alpha particle detector based on micropixel avalanche photodiodes", Phys. Part. Nucl. Lett, 10, pp.778~ (2013)
  16. Z. Sadygov, "Silicon photomultipliers : status and prospects", Phys. Part. Nucl. Lett, 17, pp.160~ (2020)
  17. S. Gundacker, "The silicon photomultiplier : fundamentals and applications of a modern solid-state photon detector", Phys. Med. Biol, 65, pp.17TR01~ (2020)[DOI]
  18. A. Sadigov, "A new detector concept for silicon photomultipliers", Nucl. Instrum. Methods Phys. Res, 824, pp.135~ (2016)[DOI]
  19. F. Ahmadov, "New phoswich detector based on LFS and p-terphenyl scintillators coupled to micropixel avalanche photodiode", Func. Mater, 24, pp.341~ (2017)[DOI]
  20. M. Holik, "Gamma ray detection performance of newly developed MAPD-3NM-II photosensor with LaBr3(Ce)crystal", Sci. Rep, 12, pp.15855~ (2022)[DOI]
  21. A. Sadigov, "Improvement of parameters of micro-pixel avalanche photodiodes", J. Inst. Met, 17, pp.P07021~ (2022)[DOI]
  22. F. Ahmadov, "Investigation of parameters of new MAPD-3NM silicon photomultipliers", J. Inst. Met, 17, pp.C01001~ (2022)[DOI]
  23. Z. Sadygov, "Three advanced designs of micro-pixel avalanche photodiodes: their present status, maximum possibilities and limitations", Nucl. Instrum. Methods Phys. Res, 567, pp.70~ (2006)[DOI]
  24. Z. Sadygov, "Technology of manufacturing micropixel avalanche photodiodes and a compact matrix on their basis", Phys. Part. Nucl. Lett, 10, pp.780~ (2014)[DOI]
  25. S. Nuruyev, "Performance of silicon photomultipliers at low temperature", J. Inst. Met, 15, pp.C03003~ (2020)[DOI]
  26. M. Holik, "Investigation of the possibility of a new detector based on SiPM in nuclear forensics", J. Inst. Met, 18, pp.C01015~ (2023)[DOI]

관련 논문AI추천

Fission counter array for pulse-mode measurements of high-flux and high-energy neutrons이필수한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제9호Measuring and unfolding fast neutron spectra using solution-grown trans-stilbene scintillation detector김성환, 김홍주, 남욱원, 박원기, 손종대, 예성준, 윤석원, 최영준, Quang Nguyen Duy, Ton Nguyen Duc, Vuong Phan Quoc한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제3호Method of the known cross sections for calibration of the fast neutron spectrometer with a single-crystal stilbene based detectorIbragimov R.F., Ryabeva E.V., Sapozhnikov V.D., Urupa I.V.한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제9호Comparative study of the pulse shape discrimination (PSD) performance of pixelated stilbene and plastic scintillator (EJ-276) arrays for a coded-aperture-based hand-held dual-particle imager부지환, 정만희한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제5호A prototype of the SiPM readout scintillator neutron detector for the engineering material diffractometer of CSNSBin Tang, Chang Huang, Guangyou Wei, Hong Xu, Lin Qiu, Mengjiao Tang, Qian Yu, Shaojia Chen, Xiuku Wang, Yadong Wei, Zhijia Sun한국원자력학회 · Nuclear Engineering and Technology2022 · 제54권 제3호Pulse shape discrimination using a stilbene scintillator array coupled to a large-area SiPM array for hand-held dual particle imager applications부지환, 정만희, Hammig Mark D.한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제2호

이 간행물의 다른 논문 (39건)