초록
The objective of this study is to investigate the degree of visualization for the macro-, micro-, and nano-structures of the cochlea with x-ray micro-CT based on a cone-beam geometry for rats. This study will provide a basic criterion to compare the visual images obtained from other techniques. Before obtaining the visual images, the hearing thresholds were obtained with auditory brainstem responses (ABR). A x-ray micro CT based on a cone-beam geometry for a small animal was used for examining the macro-, micro-, and nano-structures of the cochlea in rats. X-ray micro CT provided a clear depiction of the basal, middle, and apical cochlear turns. X-ray micro CT allows visualizing the macro-structures of the cochlea. However, it did not well depict the micro- and nano-structures of the cochlea. The present study was the first attempt to visualize the macro-structures of the cochlea with x-ray micro CT based on a cone-beam geometry for rats. To visualize the micro- and nano-structures of the cochlea, optimal parameter values of x-ray micro CT should be found and many factors such as signal-to-noise ratio, resolution, image averaging, pixel, pixel number, pixel value, exposure time, and binning should be properly considered.
Abstract
The objective of this study is to investigate the degree of visualization for the macro-, micro-, and nano-structures of the cochlea with x-ray micro-CT based on a cone-beam geometry for rats. This study will provide a basic criterion to compare the visual images obtained from other techniques. Before obtaining the visual images, the hearing thresholds were obtained with auditory brainstem responses (ABR). A x-ray micro CT based on a cone-beam geometry for a small animal was used for examining the macro-, micro-, and nano-structures of the cochlea in rats. X-ray micro CT provided a clear depiction of the basal, middle, and apical cochlear turns. X-ray micro CT allows visualizing the macro-structures of the cochlea. However, it did not well depict the micro- and nano-structures of the cochlea. The present study was the first attempt to visualize the macro-structures of the cochlea with x-ray micro CT based on a cone-beam geometry for rats. To visualize the micro- and nano-structures of the cochlea, optimal parameter values of x-ray micro CT should be found and many factors such as signal-to-noise ratio, resolution, image averaging, pixel, pixel number, pixel value, exposure time, and binning should be properly considered.
참고문헌 (17)
- 윤권하, "나노 X-선 영상과 생명의학", 고분자 과학과 기술(Polymer Science and Technology), 20(3), pp.232~238 (2009)
- Ali, O. M., "Three-dimensional CT of the middle ear and adjacent structures", Neuroradiology, 35(3), pp.238~241 (1993)
- Choi, C-H, "Mechanisms of active process and amplification in cochlea", Korean Journal of Audiology, 14(2), pp.81~87 (2010)
- Chul-Hee Choi, "Prestin and Motility of the Cochlear Outer Hair Cell", korean journal of audiology, 15(3), pp.101~106 (2011), 대한청각학회
- 최철희, "Deriving a Cochlear Transducer Function from Low Frequency Modulated Cochlear Microphonic", Communication Sciences and Disorders, 15(2), pp.232~250 (2010), 한국언어청각임상학회
- 최철희, "Preliminary Study of the Therapeutic Effect of a Nitrone-Based Antioxidant Drug(HPN-07) on Acute Acoustic Trauma", Communication Sciences and Disorders, 16(2), pp.202~210 (2011), 한국언어청각임상학회
- 최철희, "Therapeutic effect of combined antioxidant drugs (4-OHPBN plus NAC) on acute acoustic trauma in terms of distortion product otoacoustic emission", 청능재활, 7(1), pp.51~59 (2011), 한국청각언어재활학회
- 최철희, "Effectiveness of 4-hydroxy phenyl N-tert-butylnitrone (4-OHPBN) alone and in combination with other antioxidant drugs in the treatment of acute acoustic trauma in chinchilla", FREE RADICAL BIOLOGY AND MEDICINE, 44(9), pp.1772~1784, ELSEVIER SCIENCE INC
- 최철희, "Effects of delayed and extended antioxidant treatment on acute acoustic trauma", FREE RADICAL RESEARCH, 45(10), pp.1162~1172, INFORMA HEALTHCARE
- 최철희, "Nitrones as therapeutics", FREE RADICAL BIOLOGY AND MEDICINE, 45(10), pp.1361~1374, ELSEVIER SCIENCE INC
- Lane, J. I., "Middle and inner ear : Improved depiction with multiplanar reconstruction of volumetric CT data", RadioGraphics, 26(1), pp.115~124 (2006)
- Postnov, A., "High resolution micro-CT scanning as an innovatory tool for evaluation of the surgical positioning of cochlear implant electrodes", Acta Oto-laryngologica, 126(5), pp.467~474 (2006)
- Poznyakovskiy, A. A., "The creation of geometric three-dimensional models of the inner ear based on micro computer tomography data", Hearing Research, 243(1-2), pp.95~104 (2008)
- Rose, J. S., "Medical imaging in otologic diagnosis, In Hearing Disorders", pp.111~125 (1996), Allyn & Bacon
- Tomandl, B. F., "Virtual labyrinthoscopy : visualization of the inner ear with interactive direct volume rendering", Radiographics, 20(2), pp.547~558 (2000)
- Wang, G., "Can interior tomography outperform lambda tomography?", Proceedings National Academy Science USA, 107(22), pp.E92~E93 (2010)
- Whiting, B. R., "Use of Computed Tomography Scans for Cochlear Implants", Journal of Digital Imaging, 21(3), pp.323~328 (2008)