The Effect of Autotransfusion System in Minimally Invasive Total Knee Arthroplasty

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

Purpose: To evaluate the effect of autotransfusion system in minimally invasive total knee arthroplasty (TKA). Materials and Methods: Seventy-one patients who underwent unilateral minimally invasive TKA between October 2009 and June 2010 were selected. The first group included 36 patients who received standard vacuum drainage and the second group, 35 patients who underwent autologous retransfusion drainage. In the first group, allogeneic blood transfusion was performed if the postoperative hemoglobin level was <7.0 g/dL or 7.0−8.0 g/dL with the presence of a medical complication and an anemic symptom. The second group received autotransfusion and allogeneic transfusion additionally according to the same criteria. Changes in the pre- and postoperative hemoglobin level, amount of auto- or allotransfusion, and frequency of allogeneic transfusion were assessed. Results: Allogeneic transfusion was required in 13 patients (36.1%) in the first group and four patients (11.4%) in the second group. The mean allogeneic transfusion volume was significantly low in the second group compared to the first group (64.4 mL vs. 278.9 mL; p<0.05). The hemoglobin level on the 1st postoperative day compared to the preoperative level decreased by 22.6% in the first group and 11.7% in the second group. The postoperative hemoglobin level was higher in the second group (p<0.05). Conclusions: Minimally invasive unilateral TKA with an autotransfusion system can be beneficial in patients with no medical complications because of the decreased allogeneic transfusion.

Abstract

Purpose: To evaluate the effect of autotransfusion system in minimally invasive total knee arthroplasty (TKA). Materials and Methods: Seventy-one patients who underwent unilateral minimally invasive TKA between October 2009 and June 2010 were selected. The first group included 36 patients who received standard vacuum drainage and the second group, 35 patients who underwent autologous retransfusion drainage. In the first group, allogeneic blood transfusion was performed if the postoperative hemoglobin level was <7.0 g/dL or 7.0−8.0 g/dL with the presence of a medical complication and an anemic symptom. The second group received autotransfusion and allogeneic transfusion additionally according to the same criteria. Changes in the pre- and postoperative hemoglobin level, amount of auto- or allotransfusion, and frequency of allogeneic transfusion were assessed. Results: Allogeneic transfusion was required in 13 patients (36.1%) in the first group and four patients (11.4%) in the second group. The mean allogeneic transfusion volume was significantly low in the second group compared to the first group (64.4 mL vs. 278.9 mL; p<0.05). The hemoglobin level on the 1st postoperative day compared to the preoperative level decreased by 22.6% in the first group and 11.7% in the second group. The postoperative hemoglobin level was higher in the second group (p<0.05). Conclusions: Minimally invasive unilateral TKA with an autotransfusion system can be beneficial in patients with no medical complications because of the decreased allogeneic transfusion.

참고문헌 (25)

  1. Bezwada HP, "Preoperative use of recombinant human erythropoietin before total joint arthroplasty", J Bone Joint Surg Am, 85, pp.1795~1800 (2003)
  2. Rosenblatt MA, "Intraoperative hemodilution is more cost-effective than preoperative autologous donation for patients undergoing procedures associated with a low risk for transfusion", J Clin Anesth, 9, pp.26~29 (1997)
  3. Slagis SV, "Postoperative blood salvage in total hip and knee arthroplasty : a randomised controlled trial", J Bone Joint Surg Br, 73, pp.591~594 (1991)
  4. Dodd RY, "The risk of transfusion-transmitted infection", N Engl J Med, 327, pp.419~421 (1992)
  5. Dodd RY, "Early markers of HIV-1 infection in plasma donors", JAMA, 262, pp.92~93 (1989)
  6. Lemos MJ, "Blood transfusion in orthopaedic operations", J Bone Joint Surg Am, 78, pp.1260~1270 (1996)
  7. Myhre BA, "Fatalities from blood transfusion", JAMA, 244, pp.1333~1335 (1980)
  8. Goulet JA, "Intraoperative autologous transfusion in orthopaedic patients", J Bone Joint Surg Am, 71, pp.3~8 (1989)
  9. Etchason J, "The cost effectiveness of preoperative autologous blood donations", N Engl J Med, 332, pp.719~724 (1995)
  10. Dalen T, "Fever and autologous blood retransfusion after total knee arthroplasty: a prospective study of 40 autotransfusion events in 21 patients", Acta Orthop Scand, 73, pp.321~325 (2002)
  11. Bonutti PM, "Minimally invasive total knee arthroplasty : a 10-feature evolutionary approach", Orthop Clin North Am, 35, pp.217~226 (2004)
  12. "Practice guidelines for blood component therapy: a report by the American Society of Anesthesiologists Task Force on Blood Component Therapy", Anesthesiology, 84, pp.732~747 (1996)
  13. Spence RK, "Surgical red blood cell transfusion practice policies: Blood Management Practice Guidelines Conference", Am J Surg, 170, pp.3S~15S (1995)
  14. Kruskall MS, "On improving the cost-effectiveness of autologous blood transfusion practices", Transfusion, 34, pp.259~264 (1994)
  15. Bierbaum BE, "An analysis of blood management in patients having a total hip or knee arthroplasty", J Bone Joint Surg Am, 81, pp.2~10 (1999)
  16. Semkiw LB, "Postoperative blood salvage using the Cell Saver after total joint arthroplasty", J Bone Joint Surg Am, 71, pp.823~827 (1989)
  17. Groh GI, "A comparison of transfusion requirements after total knee arthroplasty using the Solcotrans autotransfusion system", J Arthroplasty, 5, pp.281~285 (1990)
  18. Sinha A, "Reinfusion of drained blood as an alternative to homologous blood transfusion after total knee replacement", Int Orthop, 25, pp.257~259 (2001)
  19. 임수재, "연속적으로 시행한 양측 슬관절 전치환술에서의 자가수혈장치는 술 후 동종수혈량을 감소시킨다", Knee Surgery and Related Research, 23(1), pp.27~32 (2011), 대한슬관절학회
  20. Yim SJ, "Effect of autotrasfusion device affecting allotransfusion after total knee arthroplasty", J Korean Knee Soc, 17, pp.246~251 (2005)
  21. Thomas D, "Autologous blood transfusion in total knee replacement surgery", Br J Anaesth, 86, pp.669~673 (2001)
  22. Abuzakuk T, "Autotransfusion drains in total knee replacement: are they alternatives to homologous transfusion?", Int Orthop, 31, pp.235~239 (2007)
  23. Wixson RL, "Reinfusion of postoperative wound drainage in total joint arthroplasty : red blood cell survival and coagulopathy risk", J Arthroplasty, 9, pp.351~358 (1994)
  24. Sauaia A, "Autologous blood transfusion does not reduce postoperative infection rates in elective surgery", Am J Surg, 178, pp.549~555 (1999)
  25. Tria AJ Jr, "Minimal incision total knee arthroplasty: early experience", Clin Orthop Relat Res, 416, pp.185~190 (2003)

관련 논문AI추천

The Efficacy and Safety of Autologous Transfusion in Unilateral Total Knee Arthroplasty김정상, 류지원, 박희곤, 유문집대한슬관절학회 · Knee Surgery and Related Research2015 · 제27권 제3호The Efficacy and Safety of Postoperative Autologous Transfusion of Filtered Shed Blood and Anticoagulant Prophylaxis in Total Knee Arthroplasty Patients문명상, Jong-Mun Jin, Kwon-Hee Park, Sung-Rak Lee대한슬관절학회 · Knee Surgery and Related Research2012 · 제24권 제1호The Efficacy of Unilateral Use of a Blood Reinfusion Device in One-Stage Bilateral Total Knee Arthroplasty인용, 김건형, 김종호, 박세욱대한슬관절학회 · Knee Surgery and Related Research2014 · 제26권 제1호Effect of Closed Suction Drain on Blood Loss and Transfusion Rates in Simultaneous Bilateral Total Knee Arthroplasty: A Prospective Randomized StudyAnoop Jhurani, Gautam M. Shetty, Nidhi Singh, Purvi Saxena, Vinay Gupta대한슬관절학회 · Knee Surgery and Related Research2016 · 제28권 제3호연속적으로 시행한 양측 슬관절 전치환술에서의 자가수혈장치는 술 후 동종수혈량을 감소시킨다송현석, 윤준희, 이상혁, 임수재, 장문석대한슬관절학회 · Knee Surgery and Related Research2011 · 제23권 제1호Efficacy of Extramedullary Femoral Component Alignment Guide System for Blood Saving after Total Knee ArthroplastyEun Seok Seo, Ji Hun Kim, Jung Myung Lee, Suk Ha Jeon대한슬관절학회 · Knee Surgery and Related Research2012 · 제24권 제2호