본문 바로가기
KERD
논문KCI 등재

Efficacy of Extramedullary Femoral Component Alignment Guide System for Blood Saving after Total Knee Arthroplasty

2

조회

0

다운로드

2

인용

0

참고문헌

키워드

초록

Purpose: To compare the extramedullary femoral alignment guide system with the conventional intramedullary alignment guide system for bleeding and transfusion rate after total knee arthroplasty (TKA). Materials and Methods: Forty-nine female TKA patients were randomized into two groups: intramedullary (IM) group vs. extramedullary (EM) group. Drained volume of blood, hemoglobin concentration, hemoglobin drop, and transfusion rate were compared between the two groups. Wound problems, bleeding-related problems and thromboembolic complications were collected. Results: The mean drained volume via vacuum drainage was less in the EM group than that in the IM group (482.9 mL vs. 266.8 mL, p=0.001). Hemoglobin at 5 days after surgery was higher in the EM group (9.3 g/dL vs. 9.9 g/dL, p=0.002) than that in the IM group. The drop in hemoglobin after 5 days was smaller in the EM group (3.5 g/dL vs. 2.9 g/dL, p=0.003) than that in the IM group. The EM group had a lower prevalence of allogeneic transfusion (45.0% vs. 20.5%, p=0.026) than that in the IM group. No significant complications developed in either group. Conclusions: The results suggest that the extramedullary femoral alignment guide technique is an advantageous method that can reduce the drained volume of blood and the allogeneic transfusion rate.

Abstract

Purpose: To compare the extramedullary femoral alignment guide system with the conventional intramedullary alignment guide system for bleeding and transfusion rate after total knee arthroplasty (TKA). Materials and Methods: Forty-nine female TKA patients were randomized into two groups: intramedullary (IM) group vs. extramedullary (EM) group. Drained volume of blood, hemoglobin concentration, hemoglobin drop, and transfusion rate were compared between the two groups. Wound problems, bleeding-related problems and thromboembolic complications were collected. Results: The mean drained volume via vacuum drainage was less in the EM group than that in the IM group (482.9 mL vs. 266.8 mL, p=0.001). Hemoglobin at 5 days after surgery was higher in the EM group (9.3 g/dL vs. 9.9 g/dL, p=0.002) than that in the IM group. The drop in hemoglobin after 5 days was smaller in the EM group (3.5 g/dL vs. 2.9 g/dL, p=0.003) than that in the IM group. The EM group had a lower prevalence of allogeneic transfusion (45.0% vs. 20.5%, p=0.026) than that in the IM group. No significant complications developed in either group. Conclusions: The results suggest that the extramedullary femoral alignment guide technique is an advantageous method that can reduce the drained volume of blood and the allogeneic transfusion rate.

참고문헌 (30)

  1. Curran JW, "Acquired immunodeficiency syndrome (AIDS) associated with transfusions", N Engl J Med, 310, pp.69~75 (1984)
  2. Conrad ME, "Diseases transmissible by blood transfusion : viral hepatitis and other infectious disorders", Semin Hematol, 18, pp.122~146 (1981)
  3. Bottner F, "Blood management after bilateral total knee arthroplasty", Clin Orthop Relat Res, (410), pp.254~261 (2003)
  4. Kourtzis N, "Blood saving protocol in elective total knee arthroplasty", Am J Surg, 187, pp.261~267 (2004)
  5. Couvret C, "A restrictive use of both autologous donation and recombinant human erythropoietin is an efficient policy for primary total hip or knee arthroplasty", Anesth Analg, 99, pp.262~271 (2004)
  6. Seo ES, "Subcutaneous versus intraarticular indwelling closed suction drainage after TKA: a randomized controlled trial", Clin Orthop Relat Res, 468, pp.2168~2176 (2010)
  7. Yamada K, "Comparison between 1-hour and 24-hour drain clamping using diluted epinephrine solution after total knee arthroplasty", J Arthroplasty, 16, pp.458~462 (2001)
  8. Tenholder M, "Intraoperative blood management in joint replacement surgery", Orthopedics, 27, pp.s663~s668 (2004)
  9. Jonsson B, "Alignment and long-term clinical results of a semiconstrained knee prosthesis", Clin Orthop Relat Res, (226), pp.124~128 (1988)
  10. Ritter MA, "Postoperative alignment of total knee replacement. Its effect on survival", Clin Orthop Relat Res, (299), pp.153~156 (1994)
  11. Tew M, "Tibiofemoral alignment and the results of knee replacement", J Bone Joint Surg Br, 67, pp.551~556 (1985)
  12. Fahmy NR, "Blood-gas and circulatory changes during total knee replacement. Role of the intramedullary alignment rod", J Bone Joint Surg Am, 72, pp.19~26 (1990)
  13. Ishii Y, "Extramedullary versus intramedullary alignment guides in total knee arthroplasty", Clin Orthop Relat Res, (318), pp.167~175 (1995)
  14. Kandel L, "Extramedullary femoral alignment instrumentation reduces blood loss after uncemented total knee arthroplasty", J Knee Surg, 19, pp.256~258 (2006)
  15. Kalairajah Y, "Blood loss after total knee replacement: effects of computer-assisted surgery", J Bone Joint Surg Br, 87, pp.1480~1482 (2005)
  16. Seo JG, "A comparison of extramedullary and intramedullary femoral component alignment guide systems in TKA", J Korean Knee Soc, 18, pp.47~54 (2006)
  17. Berman AT, "Blood loss with total knee arthroplasty", Clin Orthop Relat Res, pp.137~138 (1988)
  18. de Haan J, "Retransfusion of suctioned blood during cardiopulmonary bypass impairs hemostasis", Ann Thorac Surg, 59, pp.901~907 (1995)
  19. Semkiw LB, "Postoperative blood salvage using the Cell Saver after total joint arthroplasty", J Bone Joint Surg Am, 71, pp.823~827 (1989)
  20. Marmor L, "Effect of fibrinogen concentrates on blood loss in total knee arthroplasty", Clin Orthop Relat Res, (273), pp.136~138 (1991)
  21. Healy WL, "Evaluation of autologous shed blood for autotransfusion after orthopaedic surgery", Clin Orthop Relat Res, (299), pp.53~59 (1994)
  22. Cushner FD, "Blood loss in total knee arthroplasty", Clin Orthop Relat Res, (269), pp.98~101
  23. Levy AS, "The role of cold compression dressings in the postoperative treatment of total knee arthroplasty", Clin Orthop Relat Res, (297), pp.174~178 (1993)
  24. Chauhan SK, "Computer-assisted knee arthroplasty versus a conventional jig-based technique. A randomised, prospective trial", J Bone Joint Surg Br, 86, pp.372~377 (2004)
  25. Dutton AQ, "Computer-assisted minimally invasive total knee arthroplasty compared with standard total knee arthroplasty. A prospective, randomized study", J Bone Joint Surg Am, 90, pp.2~9 (2008)
  26. Yoo JH, "Intramedullary and extramedullary combined alignment system for tibial component placement in total knee arthroplasty", J Korean Knee Soc, 16, pp.118~124 (2004)
  27. Bathis H, "Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique", J Bone Joint Surg Br, 86, pp.682~687 (2004)
  28. Saragaglia D, "Computer-assisted knee arthroplasty: comparison with a conventional procedure. Results of 50 cases in a prospective randomized study", Rev Chir Orthop Reparatrice Appar Mot, 87, pp.18~28 (2001)
  29. 선종근, "네비게이션 시스템을 이용한 인공 슬관절 전치환술의 하지 정열의 정확도", 대한정형외과학회지, 39(6), pp.566~571 (2004), 대한정형외과학회
  30. Sparmann M, "Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study", J Bone Joint Surg Br, 85, pp.830~835 (2003)

이 간행물의 다른 논문 (10건)