본문 바로가기
KERD
논문KCI 등재

The Efficacy and Safety of Autologous Transfusion in Unilateral Total Knee Arthroplasty

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Purpose: Although allogeneic blood transfusion is the most common method of transfusion in total knee arthroplasty (TKA), there are reports showing significant decrease in the amount of allogeneic transfusion and incidence of side effects after combined use of autologous transfusion. The purpose of this study is to investigate the efficacy of using an autologous transfusion device in TKA.Materials and Methods: Patients who underwent TKA at our institution from January 2003 to January 2014 were divided into two groups: group A (n=127) who received allogeneic transfusion only in TKA and group B (n=118) who received autologous transfusion via an autologous transfusion device and allogeneic transfusion. In both groups, the patients were transfused when the hemoglobin level was below 9 g/dL. In group B, blood collected by the autologous transfusion device was transfused only once after surgery. The total blood loss volume, total transfusion volume, and the presence of side effects were assessed based on medical records.Results: Group A received 294.6 mL more allogeneic transfusion than group B (p<0.001). There were no significant differences with regard to the development of side effects between groups.Conclusions: Application of an autologous transfusion device during TKA can be effective in reducing the allogeneic transfusion volume. Moreover, allogeneic transfusion was not necessary after autologous transfusion in some patients.

Abstract

Purpose: Although allogeneic blood transfusion is the most common method of transfusion in total knee arthroplasty (TKA), there are reports showing significant decrease in the amount of allogeneic transfusion and incidence of side effects after combined use of autologous transfusion. The purpose of this study is to investigate the efficacy of using an autologous transfusion device in TKA.Materials and Methods: Patients who underwent TKA at our institution from January 2003 to January 2014 were divided into two groups: group A (n=127) who received allogeneic transfusion only in TKA and group B (n=118) who received autologous transfusion via an autologous transfusion device and allogeneic transfusion. In both groups, the patients were transfused when the hemoglobin level was below 9 g/dL. In group B, blood collected by the autologous transfusion device was transfused only once after surgery. The total blood loss volume, total transfusion volume, and the presence of side effects were assessed based on medical records.Results: Group A received 294.6 mL more allogeneic transfusion than group B (p<0.001). There were no significant differences with regard to the development of side effects between groups.Conclusions: Application of an autologous transfusion device during TKA can be effective in reducing the allogeneic transfusion volume. Moreover, allogeneic transfusion was not necessary after autologous transfusion in some patients.

참고문헌 (16)

  1. Aksoy Y, "The comparison of the effects of intraoperative bleeding control and postoperative drain clamping methods on the postoperative blood loss and the need for transfusion following total knee arthroplasty", Acta Orthop Traumatol Turc, 45, pp.190~194 (2011)
  2. Seo JG, "Analysis of the need and predictive factors for allotransfusion in autotransfused TKA & non-autotransfused TKA", J Korean Knee Soc, 16, pp.138~143 (2004)
  3. Yim SJ, "Effect of autotrasfusion device affecting allotransfusion after total knee arthroplasty", J Korean Knee Soc, 17, pp.246~251 (2005)
  4. Abuzakuk T, "Autotransfusion drains in total knee replacement", Are they alternatives to homologous transfusion? Int Orthop, 31, pp.235~239 (2007)
  5. Curran JW, "Acquired immunodeficiency syndrome(AIDS)associated with transfusions", N Engl J Med, 310, pp.69~75 (1984)
  6. Alter H, "Discovery of non-A, non-B hepatitis and identification of its etiology", Am J Med, 107, pp.16S~20S (1999)
  7. Clements DH, "Salvage and reinfusion of postoperative sanguineous wound drainage : a preliminary report", J Bone Joint Surg Am, 74, pp.646~651 (1992)
  8. Han CD, "Comparison of the postoperative blood salvage systems in total knee arthroplasty", J Korean Knee Soc, 7, pp.110~116 (1995)
  9. Kang YK, "Prebanked autologous transfusion in orthopedic surgical procedures", J Korean Orthop Assoc, 26, pp.256~260 (1991)
  10. 하동준, "The Effect of Autotransfusion System in Minimally Invasive Total Knee Arthroplasty", Knee Surgery and Related Research, 25(2), pp.65~70 (2013), 대한슬관절학회
  11. Simpson MB, "The effect of postoperative wound drainage reinfusion in reducing the need for blood transfusions in elective total joint arthroplasty : a prospective, randomized study", Orthopedics, 17, pp.133~137 (1994)
  12. Newman JH, "The clinical advantages of autologous transfusion. A randomized, controlled study after knee replacement", J Bone Joint Surg Br, 79, pp.630~632 (1997)
  13. Friedman R, "Allogeneic blood transfusions and postoperative infections after total hip or knee arthroplasty", J Bone Joint Surg Am, 96, pp.272~278 (2014)
  14. Adalberth G, "Postoperative drainage of knee arthroplasty is not necessary : a randomized study of 90 patients", Acta Orthop Scand, 69, pp.475~478 (1998)
  15. Marks RM, "Postoperative blood salvage in total knee arthroplasty using the Solcotrans autotransfusion system", J Arthroplasty, 10, pp.433~437 (1995)
  16. Lee DH, "Shed blood re-transfusion provides no benefit in computer-assisted primary total knee arthroplasty", Knee Surg Sports Traumatol Arthrosc, 19, pp.926~931 (2011)