본문 바로가기
KERD
논문KCI 등재

Radiological safety assessment for water treatment facility due to radon inhalation in Korea

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류원자력공학

초록

Water treatment facilities are facilities that use groundwater to produce potable water. Groundwater can contain radon which is a naturally occurring radionuclide, and water treatment facility workers who directly handle groundwater are at risk of internal exposure from radon inhalation. The objective of this study is to assess the internal radiation dose from radon inhalation in water treatment facility workers in Korea. To achieve this, we analyzed work processes in 6 water treatment facilities in Korea, and main process areas were investigated through interviews with workers. The airborne radon concentration was measured in the main process areas using the RAD 7 and Raduet radon detector. Radon concentrations measured in the main process areas ranged from 16.6 to 756 Bq m􀀀 3, which is below the ICRP’s reference level of 1,000 Bq m􀀀 3. The internal radiation dose due to radon inhalation ranged from 0.193 to 5.80 mSv y􀀀 1. This is about half of the ICRP’s reference level of 10 mSv y􀀀 1 for radon inhalation. This study can be used as technical data for radiological safety management of NORM industries in Korea.

Abstract

Water treatment facilities are facilities that use groundwater to produce potable water. Groundwater can contain radon which is a naturally occurring radionuclide, and water treatment facility workers who directly handle groundwater are at risk of internal exposure from radon inhalation. The objective of this study is to assess the internal radiation dose from radon inhalation in water treatment facility workers in Korea. To achieve this, we analyzed work processes in 6 water treatment facilities in Korea, and main process areas were investigated through interviews with workers. The airborne radon concentration was measured in the main process areas using the RAD 7 and Raduet radon detector. Radon concentrations measured in the main process areas ranged from 16.6 to 756 Bq m􀀀 3, which is below the ICRP’s reference level of 1,000 Bq m􀀀 3. The internal radiation dose due to radon inhalation ranged from 0.193 to 5.80 mSv y􀀀 1. This is about half of the ICRP’s reference level of 10 mSv y􀀀 1 for radon inhalation. This study can be used as technical data for radiological safety management of NORM industries in Korea.

관련 논문AI추천

국내 수처리시설 종사자 작업유형에 따른 외부피폭 방사선량 평가김광표, 김민성, 김혁재, 이성연, 전성훈(사)한국방사선산업학회 · 방사선산업학회지2023 · 제17권 제2호국내 다양한 실내환경 내 라돈농도 및 거주자의 실효선량 평가김기연, 김윤신, 김종철, 노영만, 이철민, 전형진한국환경보건학회 · 한국환경보건학회지2007 · 제33권 제4호군부대 시설 및 지하철 역사 주변 지하상가의 측정농도와 노출시간을 이용한 실내에서의 라돈 위해성 평가공진석, 김영희한국환경보건학회 · 한국환경보건학회지2016 · 제42권 제5호Radon Hazard Review of Spilled Groundwater and Tap Water in Incheon Metropolitan City Subway Station강민석, 김성철, 김진홍, 박정수, 오윤식, 이상복, 이유상, 정동하, 최세린대한방사선과학회 · Journal of Radiological Science and Technology2021 · 제44권 제6호선량 환산 관례를 이용한 생애유효선량 및 라돈피폭 위험도예측: 대학 강의실 라돈농도 중심으로권대철, 이재승대한의용생체공학회 · 의공학회지2018 · 제39권 제6호국내 라돈 취약가구에 대한 주거공간의 실내 라돈 농도에 관한 연구김성윤, 김정운, 문경덕, 민경환, 박기호, 복동석, 윤동원, 이지민, 임형준, 정희원, 주덕현, 최원용한국환경보건학회 · 한국환경보건학회지2015 · 제41권 제2호

이 간행물의 다른 논문 (59건)