Interest in the everyday hazards of radon has recently increased as such, this study attempted to examine the dangers of radon in spilled groundwater by comparing the radon concentrations of the drained groundwater and tap water used in recirculating systems in Incheon Subway restrooms. At five stations of Incheon Subway Line 1 and three stations of Line 2, drained groundwater is recirculated and used in restrooms for toilet flushing. Stations restroom tap water for hand washing that used as a control and the measured values of each were compared. With the cooperation of Incheon Transportation Corporation, samples of spilled groundwater and tap water were collected sealed to prevent contact with the air, and a DURRIDGE RAD7 was used as the experimental equipment. The collected samples were subjected to radial equilibration for approximately 3.5 h, at which the radon concentration reached its maximum, and then calculated as 10 measurements using the RAD7 underwater radon measurement mode. In all eight stations, the radon concentration in tap water was lower than the recommended amount. However, in an average of 7 out of the eight stations, the radon concentration in the effluent groundwater was 100 times higher than that in tap water. Since high radon concentrations in groundwater runoff can be harmful to humans, and there is no accurate standard for radon concentrations in domestic water, it is necessary to continuously monitor radon in water and prepare a guidance of recommended values.

Abstract

Interest in the everyday hazards of radon has recently increased as such, this study attempted to examine the dangers of radon in spilled groundwater by comparing the radon concentrations of the drained groundwater and tap water used in recirculating systems in Incheon Subway restrooms. At five stations of Incheon Subway Line 1 and three stations of Line 2, drained groundwater is recirculated and used in restrooms for toilet flushing. Stations restroom tap water for hand washing that used as a control and the measured values of each were compared. With the cooperation of Incheon Transportation Corporation, samples of spilled groundwater and tap water were collected sealed to prevent contact with the air, and a DURRIDGE RAD7 was used as the experimental equipment. The collected samples were subjected to radial equilibration for approximately 3.5 h, at which the radon concentration reached its maximum, and then calculated as 10 measurements using the RAD7 underwater radon measurement mode. In all eight stations, the radon concentration in tap water was lower than the recommended amount. However, in an average of 7 out of the eight stations, the radon concentration in the effluent groundwater was 100 times higher than that in tap water. Since high radon concentrations in groundwater runoff can be harmful to humans, and there is no accurate standard for radon concentrations in domestic water, it is necessary to continuously monitor radon in water and prepare a guidance of recommended values.

참고문헌 (20)

  1. Pervin S, "A Study of Radon Concentration in Tap Water of Dhaka City", J Environ Pollut Manag, 1(2), pp.1~7 (2018)
  2. United States Environmental Protection Agency, "National primary drinking water regulations; radon -222", Federal Register, 64(211), pp.59246~59378 (1999)
  3. Tirmarche M, "Lung Cancer Risk from Radon and Progeny and statement on radon", Annals of ICRP, 40(1), pp.1~64 (2010)
  4. 이세령, "담배연기와 담뱃잎 내 함유된 방사능 농도분석 및 위해도 평가", 방사선기술과학, 44(5), pp.489~494 (2021), 대한방사선과학회
  5. El-Araby E, "Human Risk Due to Radon and Heavy Metals in Soil", Iran J Public Health, 50(8), pp.1624~1634 (2021)
  6. 전효택, "수중 라돈 농도를 측정하기 위한 시험법 개발에 관한 연구", 한국자원공학회지, 43(1), pp.25~33 (2006), 한국자원공학회
  7. "Incheon Metropolitan City Groundwater Management Plan" (2017)[URL]
  8. Kurnaz A, "Exposure assessment of the radon in residential tap water in Kastamonu", International Journal of Radiation Research, 14(3), pp.245~250 (2016)
  9. Cook PG, "Environmental Tracers in Subsurface Hydrology" (2000), Springer
  10. "KS A ISO 18589-3. Korean Agency for Technology and Standards, Measurement of radioactivity in the environment-Soil-Part 3: Measurement of gamma-emitting radionuclides" (2012)[URL]
  11. "RAD H2O Radon in Water Accessory for the RAD7 User Manual" (2000)[URL]
  12. Malik MFI, "Determination Of Radon Concentration In Water Using RAD7 With RAD H2O Accessories", AIP Conference Proceedings, 1657(1), pp.1~5 (2015)
  13. "Sources and effects of ionizing radiation" (2000)[URL]
  14. "Busan Metropolital city office of education 2020-144 (2020). 2020 Busan Metropolitan Office of Education Student Toilet Use Status Investigation" (2020)[URL]
  15. "Enforcement rules of the Indoor air quality management" (2021)[URL]
  16. "A place with a high level of groundwater radiation...Southeastern Gyeonggi-do and Daejeon Chungbuk?"[URL]
  17. "Act of the Ministry of Environment No.918, 2021. Enforcement rules of the Indoor air quality management"[URL]
  18. 조정원, "먹는 샘물의 방사성물질 측정 및 유해성 평가", 방사선기술과학, 44(3), pp.247~252 (2021), 대한방사선과학회
  19. "Basic Information about Radon in Drinking Water" (1996)[URL]

관련 논문AI추천

이 간행물의 다른 논문 (11건)