Development of a lateral flow dipstick test for the detection of 4 strains of Salmonella spp. in animal products and animal production environmental samples based on loop-mediated isothermal amplification
0
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Objective: This study aimed to develop loop-mediated isothermal amplification (LAMP) combined with lateral flow dipstick (LFD) and compare it with LAMP-AGE, polymerase chain reaction (PCR), and standard Salmonella culture as reference methods for detecting Salmonella contamination in animal products and animal production environmental samples. Methods: The SalInvA01 primer, derived from the InvA gene and designed as a new probe for LFD detection, was used in developing this study. Adjusting for optimal conditions by temperature, time, and reagent concentration includes evaluating the specificity and limit of detection. The sampling of 120 animal product samples and 350 animal production environmental samples was determined by LAMP-LFD, comparing LAMP-AGE, PCR, and the culture method. Results: Salmonella was amplified using optimal conditions for the LAMP reaction and a DNA probe for LFD at 63°C for 60 minutes. The specificity test revealed no cross-reactivity with other microorganisms. The limit of detection of LAMP-LFD in pure culture was 3×102 CFU/mL (6 CFU/reaction) and 9.01 pg/μL in genomic DNA. The limit of detection of the LAMP-LFD using artificially inoculated in minced chicken samples with 5 hours of pre-enrichment was 3.4×104 CFU/mL (680 CFU/reaction). For 120 animal product samples, Salmonella was detected by the culture method, LAMP-LFD, LAMP-AGE, and PCR in 10/120 (8.3%). In three hundred fifty animal production environmental samples, Salmonella was detected in 91/350 (26%) by the culture method, equivalent to the detection rates of LAMP-LFD and LAMP-AGE, while PCR achieved 86/350 (24.6%). When comparing sensitivity, specificity, positive predictive value, and accuracy, LAMP-LFD showed the best results at 100%, 95.7%, 86.3%, and 96.6%, respectively. For Kappa index of LAMP-LFD, indicated nearly perfect agreement with culture method. Conclusion: The LAMP-LFD Salmonella detection, which used InvA gene, was highly specific, sensitive, and convenient for identifying Salmonella. Furthermore, this method could be used for Salmonella monitoring and primary screening in animal products and animal production environmental samples.
Abstract
Objective: This study aimed to develop loop-mediated isothermal amplification (LAMP) combined with lateral flow dipstick (LFD) and compare it with LAMP-AGE, polymerase chain reaction (PCR), and standard Salmonella culture as reference methods for detecting Salmonella contamination in animal products and animal production environmental samples. Methods: The SalInvA01 primer, derived from the InvA gene and designed as a new probe for LFD detection, was used in developing this study. Adjusting for optimal conditions by temperature, time, and reagent concentration includes evaluating the specificity and limit of detection. The sampling of 120 animal product samples and 350 animal production environmental samples was determined by LAMP-LFD, comparing LAMP-AGE, PCR, and the culture method. Results: Salmonella was amplified using optimal conditions for the LAMP reaction and a DNA probe for LFD at 63°C for 60 minutes. The specificity test revealed no cross-reactivity with other microorganisms. The limit of detection of LAMP-LFD in pure culture was 3×102 CFU/mL (6 CFU/reaction) and 9.01 pg/μL in genomic DNA. The limit of detection of the LAMP-LFD using artificially inoculated in minced chicken samples with 5 hours of pre-enrichment was 3.4×104 CFU/mL (680 CFU/reaction). For 120 animal product samples, Salmonella was detected by the culture method, LAMP-LFD, LAMP-AGE, and PCR in 10/120 (8.3%). In three hundred fifty animal production environmental samples, Salmonella was detected in 91/350 (26%) by the culture method, equivalent to the detection rates of LAMP-LFD and LAMP-AGE, while PCR achieved 86/350 (24.6%). When comparing sensitivity, specificity, positive predictive value, and accuracy, LAMP-LFD showed the best results at 100%, 95.7%, 86.3%, and 96.6%, respectively. For Kappa index of LAMP-LFD, indicated nearly perfect agreement with culture method. Conclusion: The LAMP-LFD Salmonella detection, which used InvA gene, was highly specific, sensitive, and convenient for identifying Salmonella. Furthermore, this method could be used for Salmonella monitoring and primary screening in animal products and animal production environmental samples.
참고문헌 (31)
- Kokkinos PA, "Loopmediated isothermal amplification(LAMP)for the detection of Salmonella in food", Food Anal Methods, 7, pp.512~526 (2014)[DOI]
- Jackson BR, "Outbreakassociated Salmonella enteritica serotypes and food commodities, United States, 1998-2008", Emerg Infect Dis, 19, pp.1239~1244 (2013)[DOI]
- Crim SM, "Incidence and trends of infection with pathogens transmitted commonly through food — foodborne diseases active surveillance network, 10U. S. Sites, 2006–2013", MMWR Morb Mortal Wkly Rep, 63, pp.328~332 (2014)
- Li J, "A novel visual loop-mediated isothermal amplification assay targeting gene62181533 for the detection of Salmonella spp. in foods", Food Control, 60, pp.230~236 (2016)[DOI]
- Law JW, "Rapid methods for the detection of foodborne bacterial pathogens : principles, applications, advantages and limitations", Front Microbiol, 5, pp.770~ (2015)[DOI]
- Srisawat M, "Efficient and specific detection of Salmonella in food samples using a stn-based loop-mediated isothermal amplification method", Biomed Res Int, 2015, pp.356401~ (2015)[DOI]
- Lee KM, "Review of Salmonella detection and identification methods : Aspects of rapid emergency response and food safety", Food Control, 47, pp.264~276 (2015)[DOI]
- Notomi T, "Loop-mediated isothermal amplification of DNA", Nucleic Acids Res, 28, pp.E63~ (2000)[DOI]
- Najian N, "Development of multiplex loop mediated isothermal amplification(m-LAMP)label-based gold nanoparticles lateral flow dipstick biosensor for detection of pathogenic Leptospira", Anal Chim Acta, 903, pp.142~148 (2016)[DOI]
- Mamba TS, "Lateral flow loop-mediated isothermal amplification test with stem primers : detection of Cryptosporidium species in Kenyan children presenting with Diarrhea", J Trop Med, 2018, pp.7659730~ (2018)[DOI]
- Li J, "Enhancing the signal of lateral flow immunoassays by using different developing methods", Sens Mater, 27, pp.549~561 (2015)
- Zhi-Ke Liu, "Rapid and Sensitive Detection of Salmonella in Chickens Using Loop-Mediated Isothermal Amplification Combined with a Lateral Flow Dipstick", Journal of Microbiology and Biotechnology, 29(3), pp.454~464 (2019), 한국미생물·생명공학회[DOI]
- Masphol S, "Development of loop-mediated isothermal amplification(LAMP)SYBR Green I assay as screening test for detection of 4 strains of Salmonella spp. in feed and feed ingredients", Agric Nat Resour, 55, pp.945~957 (2021)[DOI]
- Laboratory Protocol “Isolation of Salmonella spp. from food and animal faeces, "WHO", World Health Organization, 17~ (2010)
- Xia Y., "Progress in molecular biology and translational science Vol 171", pp.309~491 (2020), Academic Press
- Ledlod S, "Development of a duplex lateral flow dipstick test for the detection and differentiation of Listeria spp. and Listeria monocytogenes in meat products based on loop-mediated isothermal amplification", J Chromatogr B, 1139, pp.121834~ (2020)[DOI]
- Mei X, "Development and application of a visual loop-mediated isothermal amplification Combined with lateral flow dipstick(LAMP-LFD)method for rapid detection of Salmonella strains in food samples", Food Control, 104, pp.9~19 (2019)[DOI]
- Zhao Y, "Salmonella detection in powdered dairy products using a novel molecular tool", J Dairy Sci, 100, pp.3480~3496 (2017)[DOI]
- Kumvongpin R, "Detection assay for HPV16 and HPV18 by loop-mediated isothermal amplification with lateral flow dipstick tests", Mol Med Rep, 15, pp.3203~3209 (2017)[DOI]
- Augkarawaritsawong S, "Comparatively rapid screening tests for diagnosis of Hepatitis B virus infection using loop-mediated isothermal amplification(LAMP)paired with lateral flow dipstick(LFD), gold nanoparticles(AuNPs)and real-time turbidimetry", Sci Technol Asia, 24, pp.45~57 (2019)[DOI]
- Rajagopal R, "Evaluation of loop-mediated isothermal amplification for the detection of Salmonella from poultry matrices", Int J Food Sci Agric, 5, pp.717~727 (2021)[DOI]
- Park BH, "An integrated rotary microfluidic system with DNA extraction, loop-mediated isothermal amplification, and lateral flow strip based detection for point-of-care pathogen diagnostics", Biosens Bioelectron, 91, pp.334~340 (2017)[DOI]
- Siala M, "Screening and detecting Salmonella in different food matrices in southern Tunisia using a combined enrichment", real-time PCR method : correlation with conventional culture method, 2017, pp.8, 2416~
- Abirami N, "Evaluation of commercial loop-mediated isothermal amplification based kit and ready-to-use plating system for detection of Salmonella in naturally contaminated poultry and their processing environment", Food Control, 70, pp.74~78 (2016)[DOI]
- Hyeon JY, "Rapid detection of Salmonella in poultry environmental samples using real-time PCR coupled with immunomagnetic separation and whole genome amplification", Poult Sci, 98, pp.6973~6979 (2019)[DOI]
- Djordjevic J, "Survival of Salmonella spp. in minced meat packaged under vacuum and modified atmosphere", Braz J Microbiol, 49, pp.607~613 (2018)[DOI]
- Rimet CS, "Salmonella harborage sites in infected poultry that may contribute to contamination of ground meat", Front Sustain Food Syst, 3, pp.2~ (2019)[DOI]
- Taskila S, "Enrichment cultivation in detection of food-borne Salmonella", Food control, 26, pp.369~377 (2012)[DOI]
- Blancoa G, "Culture-and molecular-based detection of swine-adapted Salmonella shed by avian scavengers", Sci Total Environ, 634, pp.1513~1518 (2018)[DOI]
- Oerther D, "Monitoring precursor 16S rRNAs of Acinetobacter spp. in activated sludge wastewater treatment systems", Appl Environ Microbiol, 66, pp.2154~2165 (2000)[DOI]
- Rajagopal R, "Evaluation of loop-mediated isothermal amplification for the detection of Salmonella from poultry matrices", Int J Food Sci Agric, 5, pp.717~727 (2021)[DOI]
