서울시 지하철 역사의 라돈농도분포 조사
Distribution of Radon Concentration at Subway Stationin Seoul
0
조회
0
다운로드
8
인용
0
참고문헌
키워드
초록
The radon concentrations were measured to survey distribution of radon concentrations in Seoul subway stations. The radon concentrations in air and water were measured at seventeen subway stations(Mapo, Chungjongno, Sodaemun, Kwanghwamun, Chongno3ga, Ulchiro4ga, Tangdaemun, Sangildong on Line 5;Nowon, Chunggye, Hagye, Kongnung, Taenung, Mokkol, Chunghwa, Sangbong, Myomok on Line 7) using the RAdtrakTM radon gas detector, Pylon AB-5 continuous passive radon detector and liquid scintillation counting method from January to May 1999. The major results obtained from this study were as follows: The long-term mean concentrations of radon were 61.8 Bq/m3 in office, 78.9 Bq/m3 in platform, 38.2 Bq/m3 in concourse and 20.1 Bq/m3 in outdoor, respectively. These levels were less than the action level (148 Bq/m3) of the U.S. EPA. The highest level of short-term mean concentrations was 116.55 Bq/m3 at Chongno3ga station on the 5th line subway stations, while the lowest mean concentration was 19.55 Bq/m3 at Mokkol station on the 7th line subway stations. The highest concentration of radon in the road water and storing underground water in the subway stations was 234.7 KBq/m3 and 155.5 KBq/m3 in Sodaemun subway station, respectively. The results suggest that radon concentration in subway stations seems to be affected by ventilation and radon concentratin in underground water in the subway stations.
Abstract
The radon concentrations were measured to survey distribution of radon concentrations in Seoul subway stations. The radon concentrations in air and water were measured at seventeen subway stations(Mapo, Chungjongno, Sodaemun, Kwanghwamun, Chongno3ga, Ulchiro4ga, Tangdaemun, Sangildong on Line 5;Nowon, Chunggye, Hagye, Kongnung, Taenung, Mokkol, Chunghwa, Sangbong, Myomok on Line 7) using the RAdtrakTM radon gas detector, Pylon AB-5 continuous passive radon detector and liquid scintillation counting method from January to May 1999. The major results obtained from this study were as follows: The long-term mean concentrations of radon were 61.8 Bq/m3 in office, 78.9 Bq/m3 in platform, 38.2 Bq/m3 in concourse and 20.1 Bq/m3 in outdoor, respectively. These levels were less than the action level (148 Bq/m3) of the U.S. EPA. The highest level of short-term mean concentrations was 116.55 Bq/m3 at Chongno3ga station on the 5th line subway stations, while the lowest mean concentration was 19.55 Bq/m3 at Mokkol station on the 7th line subway stations. The highest concentration of radon in the road water and storing underground water in the subway stations was 234.7 KBq/m3 and 155.5 KBq/m3 in Sodaemun subway station, respectively. The results suggest that radon concentration in subway stations seems to be affected by ventilation and radon concentratin in underground water in the subway stations.
참고문헌 (14)
- "Effects and risks of ionizing radiations United Nations Scientific Committee on the Effects of Atomic Radiation 1988 report to the General Assembly" (1988), United Nations United Nations
- "International Commission on Radiological protection Lung cancer risk from indoor exposure to radon and radon daughters ICRP publication 50 Annals of the ICRP 17" (1987)
- "Health risk of radon and other internally deposited alpha emitters report of the Committee on the Biological Effects of Ionizing Radiation" (1988), National Academy Press
- "Relative performance of different types of passive dosimeters employing solid state nuclear track detectors", 73(4), pp.629~632 (1997)
- "A citizen's guide to radon", pp.4022~464 (1992)
- "우리나라 일부 주택 내 라돈 농도에 관한 조 사 연구", 16 1, pp.1~7 (1990)
- "원전주변 주택의 실내외 라돈농도에 관한 조 사 연구", 17 2, pp.60~66 (1991)
- "서 울시 지하철역내의 라돈농도분포 및 저감대책", pp.271~277 (1993)
- "주요 5개 도시의 실내외 라돈농도 조사 연구", 17(3), pp.75~82 (2002)
- "Alpha Track Detector를 이용한 실내외 라돈 농도조사에 관한 연구", 28(5), pp.71~76 (2002)
- "서울시 지하 철역사의 라돈농도 측정분석", pp.65~81 (1998)
- "지질시료 분석체계 및 정도관리시 스템개발(I)", pp.347~ (1995), 한국자원연구소
- "Building materials as a sources of indoor radon Radon and its decay products in indoor air", pp.1~43 (1988)
- "The nature and determination of the unattached fraction of radon and thron progeny Radon and its decay products in indoor air", pp.203~250 (1988)