대중교통수단 객실 내 휘발성유기화합물류 거동 특성
Study on the Movement of Volatile Organic Compounds in Public Transportation
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Objective: This study is aimed at investigating indoor air quality on public transportation (subway, train, and bus) according to changes in season and time. Methods: We evaluated TVOC and HCHO on public transportation based on the un-controlled parameters of the Ministry of Environment. We also measured temperature and humidity since they affect the concentration of TVOC and HCHO. For public transportation classification, subway lines were classified into Lines 1 to 4. Additionally, trains were classified as ITX and KTX. Results: When comparing summer and winter on public transportation, the concentrations of TVOC and HCHO did not show any particular tendency. However, the concentrations of TVOC and HCHO during traffic congestion was higher than levels during times of non-congestion on most public transportation. In summer and winter, the measurement results for temperature and humidity showed a normal range, so temperature and humidity did not affect the concentrations of TVOC and HCHO. In the case of TVOC, TVOC concentrations on new trains were found to be relatively higher than on older ones, but there was no statistically correlation. Conclusions: A survey was conducted on the indoor air quality on public transportation. This study also analyzed data based on TVOC and HCHO for designing policies and managing indoor air quality.
Abstract
Objective: This study is aimed at investigating indoor air quality on public transportation (subway, train, and bus) according to changes in season and time. Methods: We evaluated TVOC and HCHO on public transportation based on the un-controlled parameters of the Ministry of Environment. We also measured temperature and humidity since they affect the concentration of TVOC and HCHO. For public transportation classification, subway lines were classified into Lines 1 to 4. Additionally, trains were classified as ITX and KTX. Results: When comparing summer and winter on public transportation, the concentrations of TVOC and HCHO did not show any particular tendency. However, the concentrations of TVOC and HCHO during traffic congestion was higher than levels during times of non-congestion on most public transportation. In summer and winter, the measurement results for temperature and humidity showed a normal range, so temperature and humidity did not affect the concentrations of TVOC and HCHO. In the case of TVOC, TVOC concentrations on new trains were found to be relatively higher than on older ones, but there was no statistically correlation. Conclusions: A survey was conducted on the indoor air quality on public transportation. This study also analyzed data based on TVOC and HCHO for designing policies and managing indoor air quality.
참고문헌 (30)
- Kim YS, "An Investigation of Indoor Air Quality of Public Transportation System in Seoul City", Kor J. Env. Hlth. Soc, 20(1), pp.28~38 (1994)
- "Public transport distribution rate"[URL]
- 사공준, "새차 실내공기 중 포름알데히드, 휘발성 유기화합물과 운전자의 인지기능", 한국실내환경학회지, 6(2), pp.111~122 (2009), 한국실내환경학회
- 손종렬, "일부 지하철 역사내 실내공기 중 미세먼지에서의 중금속 노출에 의한 건강위해성평가", 한국생활환경학회지, 20(1), pp.29~36 (2013), 한국생활환경학회
- Kim YS, "Indoor and Outdoor Formaldehyde Concentrations in Underground Environments", Kor. J. Env. Hlth. Soc, 15(2), pp.1~9 (1989)
- 이은희, "자동차 내장부품 시험용 백의 열처리 과정에 대한 VOCs와 HCHO의 방출 특성 연구", 실내환경 및 냄새 학회지, 8(1), pp.40~49 (2009), 한국냄새환경학회
- Kim YS, "A Study on Organic Solvent Exposure in Painting Operation of Automobile Manufacturing Industry", Kor. J. Env. Hlth. Soc, 20(4), pp.10~16 (1994)
- 최세영, "가시광촉매가 처리된 자동차 내장재의 VOC 분석방법에 대한 연구", 엘라스토머 및 콤포지트, 48(3), pp.221~224 (2013), 한국고무학회
- Yoo HC, "The assessing the hvac system and measurements of indoor air quality of highway bus", The Korean Solar Energy Society, pp.263~268 (2009)
- "Management and Survey of Indoor Air Quality in Transportation"[URL]
- "Guidelines for Construction and Operation of Public Transport Vehicles for Indoor Air Quality Management"[URL]
- 황성호, "지하철역사의 호선별로 미세먼지의 노출특성에 대한 평가", 한국환경보건학회지, 43(1), pp.71~76 (2017), 한국환경보건학회
- 남궁형규, "지상과 지하역사의 실내공기질 특성과 외기영향 평가", 한국산학기술학회논문지, 17(5), pp.17~25 (2016), 한국산학기술학회[DOI]
- "Survey report on harmful substances generated during air conditioner repair work in subway station"[URL]
- 이정훈, "운행 중 대중교통차량 내 총휘발성유기화합물류(TVOC) 노출 분석", 실내환경 및 냄새 학회지, 18(1), pp.67~75 (2019), 한국냄새환경학회[DOI]
- Park DS, "Characterization of Volatile Organic Compounds Exhausted from Railroad Diesel Rolling Stocks", Proceeding of the 36th Meeting of KOSAE, pp.382~383 (2003)
- 조영민, "철도차량용 내장재의 휘발성유기화합물 방출특성 분석", 한국철도학회논문집, 11(2), pp.182~187 (2008), 한국철도학회
- Cho EJ, "Characterization of Indoor Air Quality in Underground Shopping Centers in Busan", The Annual Report of Busan Metropolitan city Institute of Health & Environment, 22(1), pp.124~141 (2012)
- "Indoor air quality of Subway and KTX: Serious"[URL]
- Jo YM, "Study on the Change of the Indoor Air Quality Inside KTX Passenger Cabin under Service", Proceeding of the 43rd Meeting of KOSAE(2006) Korean Society for Atmospheric Environment, pp.553~554 (2006)
- 여현구, "수도권지역에서 포름알데히드와 아세트알데히드의 계절별 발생원 특성", 한국대기환경학회지, 18(1), pp.11~23 (2002), 한국대기환경학회
- Fedoruk MJ, "Measurement of volatile organic compounds inside automobiles", Journal of Exposure Analysis Environmental Epidemiology, 13(1), pp.31~41 (2003)
- 안선민, "대중교통수단 중 시외버스 객실 내 유해물질 특성", 실내환경 및 냄새 학회지, 17(3), pp.199~206 (2018), 한국냄새환경학회[DOI]
- 안선민, "고속버스 운행시 공조시스템 조건에 따른 객실 내 실내공기질 변화", 실내환경 및 냄새 학회지, 17(4), pp.346~354 (2018), 한국냄새환경학회[DOI]
- "Apartment indoor air pollutant was increases in summer"[URL]
- "Indoor Air Pollution by Formaldehyde in European countries (Report No. 7 EUR 13219 EN 1990)"[URL]
- "Monographs on the evaluation of carcinogenic risks to human" (2016)[URL]
- World Health Organization (WHO), "Air quality guidelines for Europe", WHO Regional Office for Europe, 1~273 (2000)
- 윤주호, "자동차 신차의 실내에서 발생되는 휘발성유기화합물 분석 연구", 접착 및 계면, 8(1), pp.1~7 (2007), 한국접착및계면학회
- Lau WL, "Commuter exposure to aromatic VOCs in public transportation modes in Hong Kong", Sci Total Environ, 308(1-3), pp.143~155 (2003)