본문 바로가기
KERD
논문

익산지역 대기에어로졸 중 수용성 이온성분의 계절별 침적 특성

Seasonal Deposition Characteristics of Water-soluble Ion Species in Ambient Aerosol in Iksan City

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

초록

Objectives: This paper aims to investigate the seasonal deposition characteristics of water-soluble ion species by comparing the deposition amount of two samples taken according to different sampling methods of deposition for ambient aerosol such as gases and particulate matters. Methods: Deposition samples were collected using two deposition gauges in the downtown area of Iksan City over approximately two weeks of each season in 2004. The type of deposition gauges consisted of two different sampling methods known as dry gauge and a wet gauge. The dry gauge was empty and used a dry PE bottle with an inlet diameter of 9.6 cm. Before the beginning of each deposition sampling, a volume of 30-50 ml distilled ionized water was added to the wet gauge to wet the bottom during the sampling period. Deposition samples were measured twice per day and analyzed for inorganic water-soluble ion species using ion chromatography. Results: The daily deposition amounts of all measured ions in the dry gauge and the wet gauge showed a significant increase when precipitation occurred, having no difference of deposition amount between in the wet gauge and in the dry gauge. By excluding two samples from rainy days during the sampling period, the mean daily deposition of all ions in dry gauge and wet gauge were 6.58 mg/m2/day and 18.16 mg/m2/day, respectively. The mean deposition amounts of each ion species were higher in the wet gauge than in the dry gauge because of the surface difference of the sampling gauge, especially for NH4+ and SO42-. The mean deposition amounts of NH4+ and SO42- in the wet gauge were found to be about 15.4 times and 5.2 times higher than that in dry gauge, with a pronounced difference between spring and summer, while the remaining ion species were 1.1-2.0times higher in the wet gauge than in the dry gauge. Dominant species in the dry gauge were Ca2+ and NO3-,accounting for 36.4% and 18.1% of the total ion deposition, whereas those in the wet gauge were NH4+ and SO42-,accounting for 32.5% and 25.0% of the total ion deposition, respectively. Conclusion: The seasonal differences in deposition amounts of water-soluble ion species in ambient aerosol depending on the two types of different sampling methods were identified. This suggests that the removal of ambient aerosol is strongly influenced by the weather conditions of each season as well as the condition of earth’s surface, such as dry ground and water.

Abstract

Objectives: This paper aims to investigate the seasonal deposition characteristics of water-soluble ion species by comparing the deposition amount of two samples taken according to different sampling methods of deposition for ambient aerosol such as gases and particulate matters. Methods: Deposition samples were collected using two deposition gauges in the downtown area of Iksan City over approximately two weeks of each season in 2004. The type of deposition gauges consisted of two different sampling methods known as dry gauge and a wet gauge. The dry gauge was empty and used a dry PE bottle with an inlet diameter of 9.6 cm. Before the beginning of each deposition sampling, a volume of 30-50 ml distilled ionized water was added to the wet gauge to wet the bottom during the sampling period. Deposition samples were measured twice per day and analyzed for inorganic water-soluble ion species using ion chromatography. Results: The daily deposition amounts of all measured ions in the dry gauge and the wet gauge showed a significant increase when precipitation occurred, having no difference of deposition amount between in the wet gauge and in the dry gauge. By excluding two samples from rainy days during the sampling period, the mean daily deposition of all ions in dry gauge and wet gauge were 6.58 mg/m2/day and 18.16 mg/m2/day, respectively. The mean deposition amounts of each ion species were higher in the wet gauge than in the dry gauge because of the surface difference of the sampling gauge, especially for NH4+ and SO42-. The mean deposition amounts of NH4+ and SO42- in the wet gauge were found to be about 15.4 times and 5.2 times higher than that in dry gauge, with a pronounced difference between spring and summer, while the remaining ion species were 1.1-2.0times higher in the wet gauge than in the dry gauge. Dominant species in the dry gauge were Ca2+ and NO3-,accounting for 36.4% and 18.1% of the total ion deposition, whereas those in the wet gauge were NH4+ and SO42-,accounting for 32.5% and 25.0% of the total ion deposition, respectively. Conclusion: The seasonal differences in deposition amounts of water-soluble ion species in ambient aerosol depending on the two types of different sampling methods were identified. This suggests that the removal of ambient aerosol is strongly influenced by the weather conditions of each season as well as the condition of earth’s surface, such as dry ground and water.

참고문헌 (37)

  1. Sakata M, "Wet and dry deposition fluxes of trace elements in Tokyo Bay", Atmos Environ, 42(23), pp.5913~5922 (2008)
  2. Inomata Y, "Dry and wet deposition of water-insoluble dust and water-soluble chemical species during 2007 in Tsukuba, Japan", Atmos Environ, 43(29), pp.4503~4512 (2009)
  3. Seinfeld JH, "Atmospheric Chemistry and Physics: From Air Pollution to Climate Change" (2006), ohn Wiley & Sons, Inc
  4. 주재희, "강하분진의 침적 특성파악을 위한 통계학적 해석과 공간분포 분석", 한국대기환경학회지, 28(3), pp.294~305 (2012), 한국대기환경학회[DOI]
  5. Kim HS, "Chemical compositions and spatial distribution analysis of fall-out particles in Suwon area", J Kor Soc Atmos Environ, 15(1), pp.23~32 (1999)
  6. Dolislagar LJ, "A summary of the Lake Tahoe atmospheric deposition study (LTADS)", Atmos Environ, 46, pp.618~630 (2012)
  7. 한진석, "2005년 우리나라 습성강하물의 특성과 분포", 한국대기환경학회지, 22(4), pp.459~467 (2006), 한국대기환경학회
  8. 김상백, "한반도 배경지역(안면, 울진, 고산) 강수의 산성도와 화학특성", 한국대기환경학회지, 22(1), pp.15~24 (2006), 한국대기환경학회
  9. 정진도, "唐津과 安眠島地域 降水 成分의 變化特性에 關한 硏究", 한국대기환경학회지, 20(5), pp.593~601 (2004), 한국대기환경학회
  10. Kang GU, "Comparison of the chemical composition of precipitation on the western and eastern coasts of Korea", Water, Air, and Soil Pollut, 151, pp.11~34 (2004)
  11. GongunnKang, "Analysis of Precipitation Chemistry at Rural Site in the Eastern Coast, Korea", Journal of Korean Society for Atmospheric Environment, 19(E1), pp.29~39 (2003), 한국대기환경학회
  12. Lee BK, "Chemical composition of precipitation and wet deposition of major ions on the Korean peninsula", Atmos Environ, 34, pp.563~575 (2000)
  13. Kim MG, "A Study on the Behavior and Deposition of Acid Precipitation - Comparison of Chemical Composition of Rain Water between Chunchon and Seoul", J Kor Soc Atmos Environ, 15(2), pp.89~100 (1999)
  14. Kim MG, "A study on the behavior and deposition of acid precipitation - chemical composition of fog water at Chunchon (1996-1997)", J Kor Soc Atmos Environ, 14(5), pp.491~498 (1998)
  15. Lee KJ, "Acidity analysis of precipitation occurred at Woongchon, Choongnam", J Kor Soc Atmos Environ, 12(2), pp.179~187 (1996)
  16. Kang GU, "Monitoring results of acidic deposition in Korea", International Workshop on Acidic Deposition in East Asia, pp.9~12 (1993)
  17. Song KH, "A preliminary study on the acidity of precipitation in the rural area of Choongbook province", J Kor Soc Atmos Environ, 8(1), pp.38~44 (1992)
  18. 정장표, "주암호에 대한 질소화합물의 대기건식침적 특성", 한국대기환경학회지, 21(6), pp.657~666 (2005), 한국대기환경학회
  19. 김진영, "팔당호 유역에 대한 질소와 황의 건식 침적량 추정", 한국대기환경학회지, 21(1), pp.49~62 (2005), 한국대기환경학회
  20. YoungSungGhim, "Dry Deposition of Reactive Nitrogen and Sulfur Compounds in the Greater Seoul Area", The Korean Journal of Chemical Engineering, 19(1), pp.52~60 (2002), 한국화학공학회
  21. Park SU, "Estimation of nitrogen dry deposition in South Korea", Atmos Environ, 36, pp.4951~4964 (2002)
  22. Kim MK, "Chemical characterization of dustfall matters in Inchon", J Kor Soc Environ Admin, 12(2), pp.113~120 (2006)
  23. Park YY, "A study on the temporal and spatial characteristics of atmospheric deposition in Cheju area", J Kor Soc Environ Admin, 4, pp.31~45 (1997)
  24. Shin DY, "A study on the deposition amount of water-soluble ionic components in dustfall in Kwangju city", Kor J Environ Health, 22(2), pp.124~129 (1996)
  25. Kang BW, "Deposition amount of soluble components of dustfall in Seoul", J Kor Air Pollut Res Assoc, 8(4), pp.240~246 (1992)
  26. 강공언, "익산지역 대기 중 PM_10과 PM_(2.5)의 계절별 특성", 한국환경보건학회지, 37(1), pp.29~43 (2011), 한국환경보건학회
  27. 이보경, "자동연속측정시스템 개발 및 이 시스템을 이용한 서울 대기 중 PM2.5의 화학적 조성과 특성에 관한 연구", 한국대기환경학회지, 21(4), pp.439~458 (2005), 한국대기환경학회
  28. Pöschl U, "Atmospheric aerosols: composition, transformation, climate and health effects", Angew Chem Int Ed, 44, pp.7520~7540 (2005)
  29. 강공언, "호흡기 침착부위에 따른 미세먼지 중 수용성 이온성분의 일별 농도 측정", 한국환경보건학회지, 31(5), pp.387~397 (2005), 한국환경보건학회
  30. Gong Unn Kang, "Seasonal Size Distribution of Atmospheric Aerosol Particles in the Iksan", 한국환경보건학회지, 32(6), pp.543~555 (2006), 한국환경보건학회
  31. "기상청 황사관측일수" (2013)[URL]
  32. Comparison of PM2.5 and PM10 in a suburban area in Korea during April, 2003, "Kang GU", Water, Air, and Soil Pollut, 71~87 (2005)
  33. Koçak M, "Ionic composition of lower tropospheric aerosols at a Northeastern Mediterranean site: implications regarding sources and long-range transport", Atmos Environ, 38, pp.2067~2077 (2004)
  34. 강공언, "익산지역에서 황사발생시 PM2.5, PM10, TSP의 농도 특성", 한국환경보건학회지, 33(5), pp.408~421 (2007), 한국환경보건학회
  35. 원수란, "봄철과 가을철 용인지역 입자상 물질의 이온 농도", 한국대기환경학회지, 26(3), pp.265~275 (2010), 한국대기환경학회
  36. Krueger BJ, "The transformation of solid atmospheric particles into liquid droplets through heterogeneous chemistry: Laboratory insights into the processing of calcium containing mineral dust aerosol in the troposphere", Geophys Res Lett, 30, pp.1148~1151 (2003)
  37. Nakamura T, "Chemical characteristics of aerosols transported from Asia to the East China Sea: an evaluation of anthropogenic combined nitrogen deposition in autumn", Atmos Environ, 39, pp.1749~1758 (2005)

관련 논문AI추천

이 간행물의 다른 논문 (9건)