Objectives: The purpose of this study was to identify the stains causing infections in dental clinics by analyzingbacterial contamination, as well as to suggest improvements for infection control in dental clinics. Methods: In this study, a questionnaire survey of 47 dental hospitals and clinics located in Gyeonggi-do andIncheon, South Korea was administered from June 2013 to September 2013 and used to investigate the practicerates of infection control by dental hygienists and to analyze the bacterial contamination levels in dental offices. Results: In the studied institutions, the bacterial contamination levels of water lines were 20.9×103 colonyforming units (CFU)/mL for three-way syringes, 12.7×103CFU/mL for high-speed handpieces and 9.8×103CFU/mL for gargling water. The bacterial contamination levels of surfaces were 44.9×103CFU/mL in cuspidors,higher than in unit chairs (2.9×103CFU/mL) and light handles (6.7×103CFU/mL). The mean bacterial cell countof water lines and surfaces was relatively high in all establishments founded 11 years ago or more, and the meanbacterial cell count of waterline handpieces was 6.27×103CFU/mL in establishments founded between one andfive years ago, 11.16×103CFU/mL six to ten years ago and 20.04×103CFU/mL 11 years ago or more, whichsuggests that earlier foundation is associated with higher bacterial contamination levels with a statisticaldifference (p<0.01). Similarly, the mean bacterial cell count of cuspidors using water from water lines was also70.16×103CFU/mL in at least 11-year-old establishments, statistically significantly higher among in one- to fiveyear-old (4.61×103CFU/mL) and six- to ten-year-old clinics (47.89×103CFU/mL) (p<0.05). Conclusion: This study may be utilized to improve the bacterial contamination levels in dental offices bycontrolling the characteristics and environmental factors of dental offices that affect the microbial contaminationof waterlines and surfaces in such institutions.

Abstract

Objectives: The purpose of this study was to identify the stains causing infections in dental clinics by analyzingbacterial contamination, as well as to suggest improvements for infection control in dental clinics. Methods: In this study, a questionnaire survey of 47 dental hospitals and clinics located in Gyeonggi-do andIncheon, South Korea was administered from June 2013 to September 2013 and used to investigate the practicerates of infection control by dental hygienists and to analyze the bacterial contamination levels in dental offices. Results: In the studied institutions, the bacterial contamination levels of water lines were 20.9×103 colonyforming units (CFU)/mL for three-way syringes, 12.7×103CFU/mL for high-speed handpieces and 9.8×103CFU/mL for gargling water. The bacterial contamination levels of surfaces were 44.9×103CFU/mL in cuspidors,higher than in unit chairs (2.9×103CFU/mL) and light handles (6.7×103CFU/mL). The mean bacterial cell countof water lines and surfaces was relatively high in all establishments founded 11 years ago or more, and the meanbacterial cell count of waterline handpieces was 6.27×103CFU/mL in establishments founded between one andfive years ago, 11.16×103CFU/mL six to ten years ago and 20.04×103CFU/mL 11 years ago or more, whichsuggests that earlier foundation is associated with higher bacterial contamination levels with a statisticaldifference (p<0.01). Similarly, the mean bacterial cell count of cuspidors using water from water lines was also70.16×103CFU/mL in at least 11-year-old establishments, statistically significantly higher among in one- to fiveyear-old (4.61×103CFU/mL) and six- to ten-year-old clinics (47.89×103CFU/mL) (p<0.05). Conclusion: This study may be utilized to improve the bacterial contamination levels in dental offices bycontrolling the characteristics and environmental factors of dental offices that affect the microbial contaminationof waterlines and surfaces in such institutions.

참고문헌 (28)

  1. Korea National Institute of Health, "Guideline for Nosocominal Infection Control", NIH Press, ~ (2005)
  2. Yang BK, "Support of national-level institutions and hospital infection control measures", Hospital Line, 5(6), pp.90~93 (2011)
  3. Choi JH, "Legal aspects of hospital infection", 76(2), pp.286~289 (2009), Institute of Medicine
  4. "Ordinance of the Ministry of Health and Welfare, No. 145"[URL]
  5. 배성숙, "효과적인 치과병원 감염관리의 구성요소에 대한 고찰", 한국치위생학회지, 11(4), pp.557~569 (2011), 한국치위생학회
  6. "Human Immunodeficiency Virus (HIV) in Healthcare Settings"[URL]
  7. The American Occupational Safety and Health Administration, "Infection control in physician's offices", pp.1361~1369 (2000), OSHA Press
  8. The Ministry of Health and Welfare, "Oral health team: Dental Treatment in Performance of Infection Control Standard", The Ministry of Health and Welfare press, 1~3 (2006)
  9. Program for Infection Control in Dental Health-care Setting, "Korean Dental Association", KDA Press, 1~36 (2007)
  10. Jeon JS, "Status of infection control behaviors of dental hygienists", pp.2012
  11. Ayatollahi J, "Occupational hazards to dental staff", Dent Res J, 9(1), pp.2~7 (2012)
  12. King TB, "A national survey of dental hygienists' infection control attitudes and practices", J Dent Hyg, 79(2), pp.1~13 (2005)
  13. Yim YS., "Status and practice of infection control among dental hygienists", pp.2008
  14. A study on dental staff's perception of the infection management at the dental treatment rooms, "Shim HN", Kyunghee University, ~ (2008)
  15. 문상은, "수종의 쳔연물이 원내감염균에 미치는 영향", Maxillofacial Plastic Reconstructive Surgery, 24(6), pp.499~507 (2002), 대한악안면성형재건외과학회
  16. 민정희, "치과병원 진료실 내에서 메티실린 또는 반코마이신 저항성 Staphylococcus aureus의 검출", Restorative Dentistry and Endodontics, 32(2), pp.102~110 (2007), 대한치과보존학회
  17. 민희홍, "대전 일부 지역 치과종사자의 화학소독제에 관한 지식도 연구", 한국치위생학회지, 7(4), pp.455~470 (2007), 한국치위생학회
  18. The national nosocomial infection surveillance system ICU hospital infection, "The Ministry of Health and Welfare", The Ministry of Health and Welfare press, 1~5 (2008)
  19. 문선정, "일부 지역 치위생학과 학생들의 감염방지에 관한 인식 조사", 한국콘텐츠학회 논문지, 12(12), pp.313~320 (2012), 한국콘텐츠학회[DOI]
  20. Szymañska J, "Review microbial contamination of dental unit waterlines", Ann Agric Environ Med, 15(2), pp.173~179 (2008)
  21. Kim KM, "A study on the state of infection control in dental clinic", J Korean Acad Dent Hyg Edu, 7(3), pp.213~230 (2007)
  22. Park WR, "Relative Light Unit(RLU) count at the dental environment by use of Flugun and PCMX as a low temperature spray typed sterilization agent", pp.2012
  23. 이혜진, "치과진료실 환경과 구강내에서의 Staphylococcus aureus 출현 양상과 소독제의 항균력 조사", 대한구강보건학회지, 32(3), pp.405~415 (2008), 대한예방치과·구강보건학회
  24. 이치원, "충남지역 일부 다중이용시설에서 Bioaerosol의 농도에 관한 연구", 한국실내환경학회지, 3(1), pp.45~53 (2006), 한국실내환경학회
  25. "A Study of Disinfection Effecct after Hydrogen Peroxide and Silver Nitrate Complex Air Spray"[URL]
  26. Decraene V, "An assessment of the activity of a novel light-activated antimicrobial coating in a clinical environment", Infect Control Hosp Epidemiol, 29(12), pp.1181~1184 (2008)
  27. Nejatidanesh F, "Risk of contamination of different areas of dentist’s face during dental practices", Int J Prev Med, 4(5), pp.611~615 (2013)
  28. Choi MS, "A subjective symptom on indoor air quality in dental hygienist", Kor J Sanitation, 21(4), pp.1~10 (2006)