본문 바로가기
KERD
논문KCI 등재

치과용수 미생물의 정량적 및 정성적 분석

Quantitative and qualitative analysis of microorganisms in dental unit water

1

조회

0

다운로드

3

인용

0

참고문헌

키워드

주제분류치의학

초록

Objectives: The purpose of this study was to investigate the pathogenicity of microorganisms by quantitative and qualitative analysis of microorganisms before and after flushing of dental unit water. Methods: This study was conducted on the supply of high-speed handpieces, ultrasonic scalers, and air-water syringes, which sterilized from 10 dental unit chairs at a dental clinic in South Gyeongsang Province. The number of bacterial communities was calculated by collection before and after flushing (2, 4, and 6 minutes). Results: The mean number of bacteria in the handpiece water before flushing was 27,208 CFU/㎖; 2 minutes after flushing, 2,180 CFU/㎖; 4 minutes after flushing, 900 CFU/㎖; and 6 minutes after flushing, 412 CFU/㎖. Conclusions: To minimize the risk of cross-infection and intra-clinic infection in dental clinics, education and water quality monitoring may be needed.

Abstract

Objectives: The purpose of this study was to investigate the pathogenicity of microorganisms by quantitative and qualitative analysis of microorganisms before and after flushing of dental unit water. Methods: This study was conducted on the supply of high-speed handpieces, ultrasonic scalers, and air-water syringes, which sterilized from 10 dental unit chairs at a dental clinic in South Gyeongsang Province. The number of bacterial communities was calculated by collection before and after flushing (2, 4, and 6 minutes). Results: The mean number of bacteria in the handpiece water before flushing was 27,208 CFU/㎖; 2 minutes after flushing, 2,180 CFU/㎖; 4 minutes after flushing, 900 CFU/㎖; and 6 minutes after flushing, 412 CFU/㎖. Conclusions: To minimize the risk of cross-infection and intra-clinic infection in dental clinics, education and water quality monitoring may be needed.

참고문헌 (31)

  1. Kang EJ, "Infection control in the dental office", pp.22~23 (2009), Daehannarae publishing inc.
  2. Blake GC, "The incidence and control of bacterial infection of dental unit and ultrasonic scales", Br Dent J, 15(1), pp.413~416 (1963)
  3. Tyagi S, "Science regarding dental unit waterlines (DUWL): A review", Annals and Essences of Dentistry, 2(3), pp.117~122 (2010)[DOI]
  4. Lee BM, "A study on the microbial contamination of dental unit and ultrasonic scaler", J Korean Acad Prosthodont, 36(1), pp.64~80 (1998)
  5. "PD Note. dangerous secrets of dentistry" (2006)[URL]
  6. "20/20. Dirty Dental Water" (2000)[URL]
  7. Mills SE, "The dental unit waterline controversy: defusing the myths, defining the solutions", J Am Dent Assoc, 131(10), pp.1427~1441 (2000)[DOI]
  8. Ryan MP, "Ralstonia pickettii: a persistent gram-negative nosocomial infectious organism", J Hosp Infect, 62(3), pp.278~284 (2006)[DOI]
  9. Szymanska J, "Microbial contamination of dental unit waterlines", Ann Agric Environ Med, 15(2), pp.173~179 (2008)
  10. O’Donnell MJ, "Management of dental unit waterline biofilms in the 21st century", Future Microbiol, 6(10), pp.1209~1226 (2011)[DOI]
  11. Shearer BG, "Biofilm and the dental office", J Am Dent Assoc, 127(2), pp.181~189 (1996)[DOI]
  12. Centers for Disease Control and Prevention, "Guidelines for infection control in dental health-care settings - 2003", Centers for Disease Control and Prevention, 1~76 (2003)
  13. "Infection control program in the dental health care settings" (2007)[URL]
  14. "Dental hospital certification criteria" (2018)[URL]
  15. Jang BS, "Bacterial contamination of high-speed handpiece, ultrasonic scaler and air-water syringe", J Periodontal Implant Sci, 27(4), pp.941~946 (1997)[DOI]
  16. 윤혜영, "치과용 유니트 수계의 미생물 오염 및 효과적인 관리 방법", 치위생과학회지, 15(4), pp.383~392 (2015), 한국치위생과학회
  17. Miller LT, "Single derivatization method for routine analysis of bacterial whole-cell fatty acid methyl esters, including hydroxy acids", J Clin Microbiol, 16(3), pp.584~586 (1982)
  18. Szymańska J, "Bacterial contamination of water in dental unit reservoirs", Ann Agric Environ Med, 14(1), pp.137~140 (2007)
  19. Ghosh S, "Microbial biofilm: contamination in dental chair unit", Indian Medical Gazette, 2(10), pp.383~387 (2012)
  20. Cobb CM, "How does time-dependent dental unit waterline flushing affect planktonic bacteria levels?", J Dent Educ, 66(4), pp.549~555 (2002)
  21. Joen JS, "Status of infection control behaviors of dental hygienists", Master's, pp.2012
  22. Choi SJ, "A study on the status of performance of infection control standards in dental staff", Master's, pp.2010
  23. Porteous NB, "Reduction of bacterial levels in dental unit waterlines", Quintessence Int, 35(8), pp.630~634 (2004)
  24. Dutil S, "Aerosolization of mycobacteria and legionellae during dental treatment: low exposure despite dental unit contamination", Environ Microbiol, 9(11), pp.2836~2843 (2007)[DOI]
  25. Kelley ST, "Molecular analysis of shower curtain biofilm microbes", Appl Environ Microbiol, 70(7), pp.4187~4192 (2004)[DOI]
  26. 김용현, "Brevundimonas diminuta의 가성유행(Pseudo-outbreak)", Annals of Clinical Microbiology, 14(3), pp.115~117 (2011), 대한임상미생물학회
  27. Gini GA, "Ocular infection caused by Psychrobacter immobilis acquired in the hospital", J Clin Microbiol, 28(2), pp.400~401 (1990)
  28. Chmel H, "Serratia odorifera biogroup 1 causing an invasive human infection", J Clin Microbiol, 26(6), pp.1244~1245 (1988)
  29. Ricaurte JC, "Rothia dentocariosa endocarditis complicated by multiple intracranial hemorrhages", South Med J, 94(4), pp.438~440 (2001)[DOI]
  30. Karlsson MD, "Intrauterine fetal death associated with Rothia dentocariosa: a case report", Am J Obstet Gynecol, 197(5), pp.e6~e7 (2007)[DOI]
  31. Han JS, "A study about the contamination of microoranisms in private dental clinic", Doctoral, pp.2002

관련 논문AI추천