Objectives: The purpose of this study was to estimate the ventilation rate of residential homes in Korea through tracer gas methods using indoor and outdoor concentrations of carbon dioxide (CO 2 ) and CO 2 generation rates from breathing. Methods: In this study, we calculated the number of occupants in a home by time through data on the average number of people per household from the Korean National Statistical Office and also measured the amount of CO 2 generation by breathing to estimate the indoor CO 2 generation rate. To estimate the ventilation rate, several factors such as the CO 2 generation rate and average volume of residential house provided by the Korean National Statistical Office, indoor CO 2 concentrations measured by sensors, and outdoor CO 2 concentrations provided by the Korea Meteorological Administration, were applied to a mass balance model for residential indoor environments. Results: The average number of people were 2.53 per household and Koreans spend 61.0% of their day at home. The CO 2 generation rate from breathing was 13.9±5.3 L/h during sleep and 15.1±5.7 L/h in a sedentary state. Indoor and outdoor CO 2 concentrations were 849 ppm and 407 ppm, respectively. The ventilation rate in Korean residential houses calculated by the mass balance model were 42.1 m 3 /h and 0.71 air change per hour. Conclusions: The estimated ventilation rate tended to increase with an increase in the number of occupants. Since sensor devices were used to collect data, sustainable data could be collected to estimate the ventilation rate of Korean residential homes, which enables further studies such as on changes in the ventilation rate by season resulting from the activities of occupants. The results of this study could be used as a basis for exposure and risk assessment modeling.
Abstract
Objectives: The purpose of this study was to estimate the ventilation rate of residential homes in Korea through tracer gas methods using indoor and outdoor concentrations of carbon dioxide (CO 2 ) and CO 2 generation rates from breathing. Methods: In this study, we calculated the number of occupants in a home by time through data on the average number of people per household from the Korean National Statistical Office and also measured the amount of CO 2 generation by breathing to estimate the indoor CO 2 generation rate. To estimate the ventilation rate, several factors such as the CO 2 generation rate and average volume of residential house provided by the Korean National Statistical Office, indoor CO 2 concentrations measured by sensors, and outdoor CO 2 concentrations provided by the Korea Meteorological Administration, were applied to a mass balance model for residential indoor environments. Results: The average number of people were 2.53 per household and Koreans spend 61.0% of their day at home. The CO 2 generation rate from breathing was 13.9±5.3 L/h during sleep and 15.1±5.7 L/h in a sedentary state. Indoor and outdoor CO 2 concentrations were 849 ppm and 407 ppm, respectively. The ventilation rate in Korean residential houses calculated by the mass balance model were 42.1 m 3 /h and 0.71 air change per hour. Conclusions: The estimated ventilation rate tended to increase with an increase in the number of occupants. Since sensor devices were used to collect data, sustainable data could be collected to estimate the ventilation rate of Korean residential homes, which enables further studies such as on changes in the ventilation rate by season resulting from the activities of occupants. The results of this study could be used as a basis for exposure and risk assessment modeling.
참고문헌 (27)
- 양원호, "한국인의 평일 및 주말의 국소환경 시간활동 양상", 한국실내환경학회지, 6(4), pp.267~274 (2009), 한국실내환경학회
- "Improving Indoor Air Quality"[URL]
- Ring E, "Occupant Comfort, Control, and Satisfaction in Three California Mixed-mode Office Buildings", ACEEE Summer Study on Energy Efficiency in Buildings, 8.314~8.328 (2000)
- Sundell J, "On the history of indoor air quality and health", Indoor Air, 14(7), pp.51~58 (2004)
- Pérez-Padilla R, "Respiratory health effects of indoor air pollution", The International Journal of Tuberculosis and Lung Disease, 14(9), pp.1079~1086 (2010)
- "7 million premature deaths annually linked to air pollution"[URL]
- The Ministry of Land, Transport and Maritime Affairs, "Regulation for Facility in Building", ~ (2009)
- Mochida K, "Ventilation measurement using PFT method", Indoor Air (2008)
- Moon J, "Measurement of air change rate in an underground parking lot with natural ventilation by trace gas method", The Society of Air-Conditioning and Refrigerating Engineers of Korea Winter Annual Conference, pp.479~483 (2002)
- KOSIS, "Korean Statistical Information Service", Population Census, ~ (2016)
- Korean National Statistical Office, "Time use survey", ~ (2014)
- 류현수, "한국 학생들의 시간활동 양상 평가", 한국환경보건학회지, 44(2), pp.143~152 (2018), 한국환경보건학회
- Metabolically Derived Human Ventilation Rates:A Revised Approach Based Upon Oxygen Consumption Rates, "Lordo B", Environmental Protection Agency, 4-1~4-14 (2009)
- Kim J, "Indoor thermal environmental big data from IoT", Korean Society of Indoor Environment Annual Conference, pp.137~138 (2016)
- 양원호, "거주지역 실내공기 특성 및 이산화질소 노출에 관한 연구", 한국환경보건학회지, 28(2), pp.183~192 (2002), 한국환경보건학회
- Yang W, "A study on the error associated with ventilation rate calculation using different sampling intervals", Korean Journal of Environmental Health, 26(3), pp.50~54 (2000)
- Report of Global Atmosphere Watch 2016, "Korea Meteorological Administration", 16~19 (2017)
- Persily A, "Carbon dioxide generation rates for building occupants", Indoor Air, 27(5), pp.868~879 (2017)
- 허윤, "CFD를 이용한 공동주택의 자연환기량 평가방법에 관한 연구", 대한건축학회논문집, 25(06), pp.221~228 (2009), 대한건축학회
- Yang W, "Characterization of indoor air quality using multiple measurements of nitrogen dioxide", Indoor Air, 14(2), pp.105~111 (2003)
- Yeom H, "Evaluation of Natural Ventilation Rate Based on Indoor CO2 Concentration", Architectural Institute of Korea Conference Proceedings, 38(1), pp.376~379 (2018)
- 최석용, "환기량 변화에 따른 신축공동주택의 실내공기질 개선효과 검토", 설비공학 논문집, 18(8), pp.649~655 (2006), 대한설비공학회
- Jacobsen E, "Risk assessment of 3D printers and 3D printed products", The Danish Environmental Protection Agency, 161, pp.28~35 (2017)
- Chan W, "Analysis of air leakage measurements of US houses", Energy and Buildings, 66, pp.616~625 (2013)
- 이동석, "대규모 건물의 기밀성능 측정기준 수립에 관한 연구", 한국태양에너지학회 논문집, 34(1), pp.117~124 (2014), 한국태양에너지학회
- Lee K, "The Comparison of Measured and Calculated Air Leakage Rate caused by Wind Pressure and Temperature Difference in HighRise Apartments", Architectural Institute of Korea Conference Proceedings, 24(2), pp.1127~1130 (2004)
- Shuqing C, "CO2 tracer gas concentration decay method for measuring air change rate", Building and Environment, 84, pp.162~169 (2015)