본문 바로가기
KERD
논문

초 · 중 · 고등학교의 이산화탄소 농도 및 환기량 평가

Evaluation of Carbon Dioxide Concentrations and Ventilation Rates in Elementary, Middle, and High Schools

2

조회

0

다운로드

6

인용

0

참고문헌

키워드

초록

Objectives: Much attention has been paid to indoor air quality. Ventilation within schools is important because of indoor air quality and its effect on health and learning performance. In this study, we evaluated the carbon dioxide (CO2) concentrations and ventilation rates in schools. Methods: This study measured the concentration of CO2 in elementary, middle, and high school classrooms over six months. The seasons during the study were summer, fall, and winter. Sensor-based monitoring was used and the basic characteristics of the classroom were investigated. The body surface area of the students was used to calculate the CO2 generation rate, and the air change per hour (ACH) was evaluated using mass balance modeling. Results: The average CO2 concentration measured in most schools exceeded 1000 ppm. The ventilation rates varied from season to season. Compared to the recommended ventilation rate of 4.9 ACH, the roughly 3 ACH calculated in this study indicates that most schools possessed insufficient ventilation. Conclusions: The concentration of CO2 in school classrooms could be an indicator of indoor air quality and can affect students' learning ability. In this study, CO2 concentrations exceeding the standard indicate a lack of ventilation along with problems with indoor air quality. Therefore, appropriate improvements are needed to overcome these problems.

Abstract

Objectives: Much attention has been paid to indoor air quality. Ventilation within schools is important because of indoor air quality and its effect on health and learning performance. In this study, we evaluated the carbon dioxide (CO2) concentrations and ventilation rates in schools. Methods: This study measured the concentration of CO2 in elementary, middle, and high school classrooms over six months. The seasons during the study were summer, fall, and winter. Sensor-based monitoring was used and the basic characteristics of the classroom were investigated. The body surface area of the students was used to calculate the CO2 generation rate, and the air change per hour (ACH) was evaluated using mass balance modeling. Results: The average CO2 concentration measured in most schools exceeded 1000 ppm. The ventilation rates varied from season to season. Compared to the recommended ventilation rate of 4.9 ACH, the roughly 3 ACH calculated in this study indicates that most schools possessed insufficient ventilation. Conclusions: The concentration of CO2 in school classrooms could be an indicator of indoor air quality and can affect students' learning ability. In this study, CO2 concentrations exceeding the standard indicate a lack of ventilation along with problems with indoor air quality. Therefore, appropriate improvements are needed to overcome these problems.

참고문헌 (22)

  1. A study on indoor air pollution characterization and management, "Ministry of Environment", ~ (2002)
  2. Yang W, "Characterization of indoor air quality using multiple measurements of nitrogen dioxide", Indoor Air, 14, pp.105~111 (2004)
  3. Landrigan P, "Environmental hazards for children in USA", International Journal of Occupational Medicine and Environmental Health, 11(2), pp.189~194 (1998)
  4. Lee S, "Indoor and outdoor air quality investigation at schools in Hong Kong", Chemosphere, 41(1-2), pp.109~113 (2000)
  5. Yang W, "Time-activity pattern of students and indoor air quality of school", Korean Institute of Educational Facilities, 21(6), pp.17~22 (2014)
  6. Korea Ministry of Government Legislation, "Enforcement decree of the school health act", ~ (2018)
  7. Jeon E, "Evaluation of indoor air quality in urban school", Korean Journal of Environmental Education, 12(2), pp.73~80 (1999)
  8. Camilla V, "Ventilation positive pressure intervention effect on indoor air quality in a school building with moisture problems", Environmental Research and Public Health, 15(2), pp.230~ (2018)
  9. 임완철, "교실 내 공기 중 이산화탄소 농도가 학습에 미치는 효과에 대한 문헌 연구", 환경교육, 28(2), pp.134~145 (2015), 한국환경교육학회[DOI]
  10. Shendell D, "Associations between classroom CO2concentrations and student attendance in Washington and Idaho", Indoor Air, 14, pp.333~341 (2004)
  11. Report of Global Atmosphere Watch, "National Institute of Meteorological Sciences", ~ (2018)
  12. Lee J, "Determination of body surface area and formulas to estimate body surface area using the alginate method", Journal of Physiological Anthropology, 27(2), pp.71~82 (2008)
  13. Study on the Improvement of exposure factors of korean adults on risk assessment, "National Institute of Environmental Research", ~ (2018)
  14. David A, "Carbon Dioxide Levels and Ventilation Rates in Schools", International Journal of Ventilation, 1(1), pp.45~52 (2002)
  15. Tichenor B, "Evaluating sources of indoor air pollution", Air & Waste Management Association, 40, pp.487~492 (1990)
  16. Kraenzmer M, "Modeling and continuous monitoring of indoor air pollutants for identification of sources and sinks", Environmental International, 25(5), pp.541~551 (1999)
  17. 양원호, "이산화질소 다중측정을 이용한 실내공기질 특성에 관한 연구 : 한국의 서울과 호주의 브리스베인에서 노출평가 및 비교", 박사, 환경보건, pp.2001
  18. Annual climatological report, "Korea Meteorological Adminstration", ~ (2017)
  19. 박연지, "고등학교 무용연습공간의 실내공기질 연구: PM10, CO2를 대상으로", 한국체육학회지, 58(3), pp.317~326 (2019), 한국체육학회[DOI]
  20. Investment of Air Change per Hour (ACH)in a Elementary School, "Kim S", Korean Society for Atmospheric Environment, 406~ (2010)
  21. 박진현, "시간활동양상 및 이산화탄소 농도를 이용한 한국 주택 환기량 추정", 한국환경보건학회지, 45(1), pp.1~8 (2019), 한국환경보건학회[DOI]
  22. A study on the CO2 concentration control in lecture room, "Kim S", Korea Institute of Architectural Sustainable Environment and Building Systems, 97~100 (2012)

관련 논문AI추천

이 간행물의 다른 논문 (10건)