시간활동양상에 따른 주택의 시간대별 실내·실외 초미세먼지 농도비
Indoor to Outdoor Ratio of Fine Particulate Matter by Time of the Day in House According to Time-activity Patterns
2
조회
0
다운로드
7
인용
0
참고문헌
키워드
초록
Objective: The purpose of this study was to evaluate the indoor to outdoor ratio (I/O ratio) of time activity patterns affecting PM2.5 concentrations in homes in Korea through a simulation. Methods: The time activity patterns of homemakers were analyzed based on the ‘Time-Use Survey’ data of the National Statistical Office in 2014. From September 30 to October 2, 2019, the experimenter lived in multi family housing located in Guro-gu, Seoul. The I/O ratio of PM2.5 concentration was measured by installing sensor-based instruments. Results: The average indoor and outdoor PM2.5 concentrations during the three days were 33.1±48.9 and 45.9±25.3 μg/m3 , respectively. The average I/O ratio was 0.75±0.60. The indoor concentration tended to increase when PM2.5 source activity such cooking and cleaning was present and outdoor PM2.5 was supplied through ventilation. Conclusions: This study could be used as basic data for estimating indoor PM2.5 concentrations with personal activity pattern and weather conditions using outdoor concentrations.
Abstract
Objective: The purpose of this study was to evaluate the indoor to outdoor ratio (I/O ratio) of time activity patterns affecting PM2.5 concentrations in homes in Korea through a simulation. Methods: The time activity patterns of homemakers were analyzed based on the ‘Time-Use Survey’ data of the National Statistical Office in 2014. From September 30 to October 2, 2019, the experimenter lived in multi family housing located in Guro-gu, Seoul. The I/O ratio of PM2.5 concentration was measured by installing sensor-based instruments. Results: The average indoor and outdoor PM2.5 concentrations during the three days were 33.1±48.9 and 45.9±25.3 μg/m3 , respectively. The average I/O ratio was 0.75±0.60. The indoor concentration tended to increase when PM2.5 source activity such cooking and cleaning was present and outdoor PM2.5 was supplied through ventilation. Conclusions: This study could be used as basic data for estimating indoor PM2.5 concentrations with personal activity pattern and weather conditions using outdoor concentrations.
참고문헌 (28)
- 최영태, "초 · 중 · 고등학교의 이산화탄소 농도 및 환기량 평가", 한국환경보건학회지, 46(3), pp.344~352 (2020), 한국환경보건학회[DOI]
- "IARC Monographs Vol. 109: Outdoor air pollution" (2015)[URL]
- "Health effects of particulate matter" (2013)[URL]
- Di Q, "Air pollution and mortality in the Medicare population", New England Journal of Medicine, 376, pp.2513~2522 (2017)
- Nadali A, "Indoor and outdoor concentration of PM10, PM2.5and PM1 in residential building and evaluation of negative air ions (NAIs) in indoor PM removal", Environ Pollut Bio, 32(1), pp.47~55 (2020)
- 양원호, "한국인의 평일 및 주말의 국소환경 시간활동 양상", 한국실내환경학회지, 6(4), pp.267~274 (2009), 한국실내환경학회
- Hwang Y, "Contribution of microenvironments to personal exposures to PM10 and PM2.5 in summer and winter", Atmospheric Environment, 175, pp.192~198 (2018)
- Burke J, "A population exposure model for particulate matter: case study results for PM2.5 in Philadelphia, PA", J Expo Anal Environ Epidemiol, 11, pp.470~489 (2001)
- Leung D, "Outdoor-indoor air pollution in urban environment: challenges and opportunity", Front. Environ. Sci, 2, pp.1~7 (2015)
- Diapouli E, "Estimating the concentration of indoor particles of outdoor origin: a review", J. Air Waste Manag. Assoc, 63(10), pp.1113~1129 (2013)
- Park J, "Assessment of PM2.5 population exposure of a community using sensor- based air monitoring instruments and similar time-activity groups", Atmos. Pollut. Res
- Yang W, "Environmental health surveillance system for a population using advanced exposure assessment", Toxics
- Bo M, "Assessment of indoor-outdoor particulate matter air pollution : A review", Atmosphere, 8, pp.1~18 (2017)
- Chen C, "Review of relationship between indoor and outdoor particles : I", O ratio, infiltration factor and penetration factor, 2011, pp.45, 275~288
- Statistics Korea, "Time-Use Survey", ~ (2014)
- Huang Y, "Personal exposure to household particulate matter, household activities and heart rate variability among housewives", PLoS One, 9, pp.1~5 (2014)
- Massey D, "Seasonal trends of PM10, PM5.0, PM2.5 & PM1.0 in indoor and outdoor environments of residential homes located in North-Central India", Build. Environ, 47, pp.223~231 (2012)
- Cho S, "A personal particulate matter exposure monitor to support household air pollution exposure and health studies", 2016 IEEE Global Humanitarian Technology Conference (GHTC), pp.817~818 (2016)
- 이현수, "시간활동양상과 국소환경 농도를 이용한 전업주부의 유해오염물질 노출 예측", 실내환경 및 냄새 학회지, 13(3), pp.159~167 (2014), 한국냄새환경학회
- Dou C, "Cooking oil fume-derived PM2.5 induces apoptosis in A549 cells and MAPK", NF-кB, Environ. Sci. Pollut. Res, pp.2018, 25[DOI]
- 김희갑, "춘천의 가정에서 미세분진(PM2.5)과 입자상 다환방향족탄화수소에 대한 계절적 노출 변동", 환경독성보건학회지, 21(1), pp.57~69 (2006), 환경독성보건학회
- Indoor environment and noise research division environmental infrastructure research, "National Institute of Environmental Research", Department National Institute of Environmental Research, ~ (2010)
- Research for particulate matter management plan for multi-use facilities, "Korean Ministry of Environment", ~ (2015)
- Zou J, "Using big data from air quality monitors to evaluate indoor PM2.5 exposure in buildings: case study in Beijing", Environment Pollution, 240, pp.839~847 (2018)
- Massey D, "Indoor", outdoor relationship of fine particles less than 25 μm (PM2.5) in residential homes locations in central Indian region, 2009, pp.44, 2037~2045
- Lee S, "Indoor air quality at restaurants with different styles of cooking in metropolitan Hong Kong", Sci. Total Environ, 279, pp.181~193 (2001)
- Korean Environmental Industry & Technology Institute, "Exposure characteristics to particulate matter of children in urban susceptible buildings and facilities", ~ (2019)
- Huang Y, "Personal exposure to household particulate matter, household activities and heart rate variability among housewives", Plos One, 9 (2014)
