국내 다양한 미소환경에서의 계절별 초미세먼지 및 오존 실내ㆍ외 농도 비
Seasonal Indoor-to-Outdoor Ratio (I/O Ratio) of Fine Particulate Matter and Ozone Concentrations in Various Microenvironments in South Korea
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Background: Exposure to fine particulate matter (PM2.5) and ozone (O ) poses potential health risks. The 3 Indoor-to-Outdoor ratio (I/O ratio) is a valuable tool for understanding indoor air quality and identifying potential indoor sources. Objectives: The objective of this study was to determine I/O ratios of PM2.5 and O by different 3 microenvironments and seasons in Korea. Methods: From December 2021 to November 2023, indoor concentrations of PM2.5 and O were monitored 3 3 3 every hour in 13 microenvironments (residential indoor, office, school, restaurant, pub, café, study café, private educational institute, PC room, billiard room, screen golf center, supermarket, and shopping mall) in Korea. Hourly outdoor concentrations of PM2.5 and O were obtained from local air quality monitoring stations, provided by airkorea.or.kr. The hourly I/O ratio was calculated by the indoor and outdoor concentrations. Results: At the pub, billiard room, and PC room, the median PM2.5 I/O ratio exceeded 1 in all seasons, except in spring at the PC room (0.9), suggesting indoor smoking as a potential cause. The median PM2.5 I/O ratio at the restaurant exceeded 1 in winter, autumn, and summer, except for spring (0.9), indicating signif icant PM2.5 emission sources in the restaurant. The median O I/O ratio was below 0.5 in all seasons and 3 microenvironments. Conclusions: This study provided useful data on relationships between indoor and outdoor pollution in various microenvironments by seasons. These I/O ratios could be applied for more accurate exposure assessment to protect health of human.
Abstract
Background: Exposure to fine particulate matter (PM2.5) and ozone (O ) poses potential health risks. The 3 Indoor-to-Outdoor ratio (I/O ratio) is a valuable tool for understanding indoor air quality and identifying potential indoor sources. Objectives: The objective of this study was to determine I/O ratios of PM2.5 and O by different 3 microenvironments and seasons in Korea. Methods: From December 2021 to November 2023, indoor concentrations of PM2.5 and O were monitored 3 3 3 every hour in 13 microenvironments (residential indoor, office, school, restaurant, pub, café, study café, private educational institute, PC room, billiard room, screen golf center, supermarket, and shopping mall) in Korea. Hourly outdoor concentrations of PM2.5 and O were obtained from local air quality monitoring stations, provided by airkorea.or.kr. The hourly I/O ratio was calculated by the indoor and outdoor concentrations. Results: At the pub, billiard room, and PC room, the median PM2.5 I/O ratio exceeded 1 in all seasons, except in spring at the PC room (0.9), suggesting indoor smoking as a potential cause. The median PM2.5 I/O ratio at the restaurant exceeded 1 in winter, autumn, and summer, except for spring (0.9), indicating signif icant PM2.5 emission sources in the restaurant. The median O I/O ratio was below 0.5 in all seasons and 3 microenvironments. Conclusions: This study provided useful data on relationships between indoor and outdoor pollution in various microenvironments by seasons. These I/O ratios could be applied for more accurate exposure assessment to protect health of human.
참고문헌 (29)
- Klepeis NE, "The National Human Activity Pattern Survey(NHAPS) : a resource for assessing exposure to environmental pollutants", J Expo Anal Environ Epidemiol, 11(3), pp.231~252 (2001)
- Yang W, "Determinants of residential indoor and transportation activity times in Korea", J Expo Sci Environ Epidemiol, 21(3), pp.310~316 (2011)
- Lee S, "A study on characteristics of indoor air pollutants using regression analysis in public facilities", J Korean Soc Environ Anal, 16(2), pp.123~131 (2013)
- Hoskins JA, "Survival and sustainability: environmental concerns in the 21st century", pp.665~676 (2011), Springer
- "Household air pollution"[URL]
- Morris RD, "Airborne particulates and hospital admissions for cardiovascular disease: a quantitative review of the evidence", Environ Health Perspect, 109(Suppl 4), pp.495~500 (2001)
- Pope CA 3rd, "Lung cancer, cardiopulmonary mortality, and long-term exposure to fine particulate air pollution", JAMA, 287(9), pp.1132~1141 (2002)
- Martins NR, "Impact of PM2.5 in indoor urban environments: a review", Sustain Cities Soc, 42, pp.259~275 (2018)
- Turner MC, "Long-term ozone exposure and mortality in a large prospective study", Am J Respir Crit Care Med, 193(10), pp.1134~1142 (2016)
- Nazaroff WW, "Indoor ozone : concentrations and influencing factors", Indoor Air, 32(1), pp.e12942~ (2022)
- Li T, "Household concentrations and personal exposure of PM2.5 among urban residents using different cooking fuels", Sci Total Environ, 548-549, pp.6~12 (2016)
- Lee M, "An analysis on the concentration characteristics of PM2.5 in Seoul, Korea from 2005 to 2012", Asia-Pacific J Atmos Sci, 50(Suppl 1), pp.585~594 (2014)
- Shin BC, "Seasonal and diurnal variations of surface ozone at Ieodo in the East China Sea", Korean Soc Atmos Environ, 23(6), pp.631~639 (2007)
- Gerharz LE, "Applying indoor and outdoor modeling techniques to estimate individual exposure to PM2.5 from personal GPS profiles and diaries: a pilot study", Sci Total Environ, 407(18), pp.5184~5193 (2009)
- Guak S, "A model for population exposure to PM2.5: identification of determinants for high population exposure in Seoul", Environ Pollut, 285, pp.117406~ (2021)
- Lee S, "Seasonal differences in determinants of time location patterns in an urban population : a large population-based study in Korea", Int J Environ Res Public Health, 14(7), pp.672~ (2017)
- Lee K, "Differential impacts of smoke-free laws on indoor air quality", J Environ Health, 70(8), pp.24~54 (2008)
- Lim S, "Personal exposures to PM2.5 and their relationships with microenvironmental concentrations", Atmos Environ, 47, pp.407~412 (2012)
- Lee JH, "Evaluation of indoor ETS exposure levels in pubs, pc game rooms, and billiards halls around a university campus using PM2.5 concentrations", J Korean Soc Occup Environ Hyg, 26(4), pp.411~417 (2016)
- Weschler CJ, "Ozone in indoor environments : concentration and chemistry", Indoor Air, 10(4), pp.269~288 (2000)
- Zhang H, "Chemical characterization of volatile organic compounds(VOCs)emitted from multiple cooking cuisines and purification efficiency assessments", J Environ Sci(China), 130, pp.163~173 (2023)
- "Enforcement rule of the indoor air quality control act, article 3 (maintenance standards)"[URL]
- "Enforcement rule of the school health act, article 3 paragraph 1 subparagraph 3-2 (standards for maintenance and management of air quality)"[URL]
- "Guidelines for office air management under the occupational safety and health act, article 2"[URL]
- Kim HH, "Indoor exposure and health risk of polycyclic aromatic hydrocarbons (PAHs) via public facilities PM2.5, Korea (II)", Asian J Atmos Environ, 8(1), pp.35~47 (2014)
- Lee HK, "A study on the seasonal correlation between O3 and PM2.5 in Seoul in 2017", J Korean Soc Atmos Environ, 36(4), pp.533~542 (2020)
- Benabed A, "PM10, PM2.5, PM1, and PM0.1 resuspension due to human walking", Air Qual Atmos Health, 15(9), pp.1547~1556 (2022)
- Wallace L, "Continuous weeklong measurements of personal exposures and indoor concentrations of fine particles for 37 health-impaired North Carolina residents for up to four seasons", Atmos Environ, 40(3), pp.399~414 (2006)
- Khoder MI, "Diurnal, seasonal and weekdays-weekends variations of ground level ozone concentrations in an urban area in greater Cairo", Environ Monit Assess, 149(1-4), pp.349~362 (2009)