A reduction in risk of occupational exposure to chemical hazards within the workplace has been the focus of attention both through industry initiatives and legislation. The aims of this study were to develop an exposure matrix by industry and process, and to apply this matrix to control the risk of occupational exposure to Dichloromethane (DCM). The exposure matrix is a tool to convert information on industry and process into information on occupational risk. The exposure matrix comprised industries and processes involving DCM, based on an exposure database provided by KOSHA (the Korean Occupational Safety and Health Agency), which was gathered from a workplace hazards evaluation program in Korea. The risk assessment of the exposure matrix was performed using Hallmark risk assessment tool. The results of the risk assessment were indicated by a Danger Value (DV) calculated from the combination of hazard rating (HR),duration of use rating (DUR), and risk probability rating (RPR) of exposure to the chemical, and were divided into four control bands which were related to control measures. The applicability of the risk assessment of the exposure matrix was evaluated by a field study, and survey of the employees of the exposure matrix groups. Among 45 industries examined,this study found that greater attention should be paid to two industries: the manufacture of other optical instruments and photographic equipment, and the manufacture of printing ink, and to one process among 47 examined, the packing process in the manufacture of printing ink, because these were regarded as carrying the highest risk. This tool of a risk assessment for the exposure matrix can be applied as a general exposure information system for hazard control, risk quantification, setting the occupational exposure limit, and hazard surveillance. The exposure matrix includes workforce data, and it provides information on the numbers of exposed workers in Korea by agent, occupation, and level of exposure and risk.

Abstract

A reduction in risk of occupational exposure to chemical hazards within the workplace has been the focus of attention both through industry initiatives and legislation. The aims of this study were to develop an exposure matrix by industry and process, and to apply this matrix to control the risk of occupational exposure to Dichloromethane (DCM). The exposure matrix is a tool to convert information on industry and process into information on occupational risk. The exposure matrix comprised industries and processes involving DCM, based on an exposure database provided by KOSHA (the Korean Occupational Safety and Health Agency), which was gathered from a workplace hazards evaluation program in Korea. The risk assessment of the exposure matrix was performed using Hallmark risk assessment tool. The results of the risk assessment were indicated by a Danger Value (DV) calculated from the combination of hazard rating (HR),duration of use rating (DUR), and risk probability rating (RPR) of exposure to the chemical, and were divided into four control bands which were related to control measures. The applicability of the risk assessment of the exposure matrix was evaluated by a field study, and survey of the employees of the exposure matrix groups. Among 45 industries examined,this study found that greater attention should be paid to two industries: the manufacture of other optical instruments and photographic equipment, and the manufacture of printing ink, and to one process among 47 examined, the packing process in the manufacture of printing ink, because these were regarded as carrying the highest risk. This tool of a risk assessment for the exposure matrix can be applied as a general exposure information system for hazard control, risk quantification, setting the occupational exposure limit, and hazard surveillance. The exposure matrix includes workforce data, and it provides information on the numbers of exposed workers in Korea by agent, occupation, and level of exposure and risk.

참고문헌 (21)

  1. Rossberg,M, "“Chlorinated Hydrocarbons” in Ullmann’s Encyclopedia of Industrial Chemistry, Wiley-VCH" (2006), Weinheim
  2. "Office of Environmental Health Hazard Assessment,“Dichloromethane”, Public Health Goals for Chemicals in Drinking Water, California Environmental Pro tection Agency, Available from (URL):"[URL]
  3. "Ministry of Environment, PRTR (Pollutant Release and Transfer Registers), Available from (URL"[URL]
  4. Rioux,J, "Methylene chloride poisoning:a paradigmatic review", Journal of Emergency Medical, 6(3), pp.227~238 (1988)
  5. Fagin, J, "Carbon monoxide poisoning secondary to inhaling methylene chloride", British Medical Jounal, 281(6253), pp.1461~ (1980)
  6. Kobayashi, A, "Severe optic neuropathy caused by dichloromethane inhalation", Journal of Ocular Pharmacology and Therapeutics, 24(6), pp.607~612 (2008)
  7. Cordes, D. H, "Chemically induced hepatitis after inhaling organic solvents", The Western Journal of Medicine, 148(4), pp.458~460 (1988)
  8. Wells,G, "Methylene chloride burns", British Journal of Industrial Medicine, 41(3), pp.420~ (1984)
  9. Bell, B, "Methylene chloride exposure and birthweight in Monroe County, New York", Environmental Research, 55(1), pp.31~39 (1991)
  10. "USDHHS (U.S. Department of Health and Human Services), Toxicological Profile for Methylene Chloride,Available from(URL):"[URL]
  11. "IARC (International Agency for Research on Cancer)Lists of IARC Evaluations; Available from (URL):"[URL]
  12. "American Conference of Governmental Industrial Hygienists ACGIH), 2010 TLVs & BEIs, threshold limit values for chemical substances and physical agents and biological exposure indices", ISBN 978-1-882417-79-7 (2010)
  13. "Ministry of Employment and Labor, Occupational Exposure Limits for Chemical and Physical Hazard" (2010), Ministry of Employment and Labor Standard No.2010-44
  14. "OSHA(Occupational Safety and Health Administration),Occupational Safety and Health Standards,Standard No. 1910.1052, Available from(URL):"[URL]
  15. Benke, G, "Beyond the job exposure matrix (JEM): the task exposure matrix (TEM)", The Annals of Occupational Hygiene, 44, pp.475~482 (2000)
  16. "AIHA (American Industrial Hygiene Association),Hallmark Risk Assessment Tool in Guidance for Conducting Control Banding Analysis, AIHA", ~ (2007)
  17. "Statistics Korea, Korean Standard Industrial Classification(KSIC)", 9th revision (2001)
  18. Hass, J. M, "Industrial hygiene ABCs", Professional Safety, 50(3), pp.38~41 (2005)
  19. Ha, K. C, "A study on Volatile Organic Compounds(VOC) in Environmental Tobacco Smoke (ETS) at indoor office environments", Journal of Korean Society of Environmental Health, 27(3), pp.1~112 (2001)
  20. Korea Occupational Safety and Health Agency(KOSHA), Application of Matrix and Risk Assessment of Industries, Processes, and Job, Research Report, , ~ (2008)
  21. Pukkla, E, "National job-exposure matrix in analysis of census-basedestimates of occupational cancer risk", Scandinavian Journal of Work Environmental Health, 31(2), pp.97~107 (2005)

관련 논문AI추천

공정 범주에 따른 ECETOC TRA 모델 평가로부터 도출한 한국 작업장 노출 평가 개선 방안김기은, 김상현, 김종운, 전현표, 정연승한국환경보건학회 · 한국환경보건학회지2019 · 제45권 제2호작업환경실태조사 및 작업환경측정자료(2018~2022) 결과를 활용한 우리나라 전자산업에서의 고위험물질 노출 특성 -디클로로메탄, 트리클로로메탄, 수산화테트라메틸암모늄 중심으로-권세영, 김형렬, 류현철, 안진수, 윤진하, 윤충식, 이나은, 이상만, 이재환, 장재필, 하권철, 함승헌, 황성호한국환경보건학회 · 한국환경보건학회지2024 · 제50권 제3호메탄올 작업장 노출 평가에의 EU REACH 프로토콜 적용: Targeted Risk Assessment나진성, 송문환, 최은경한국환경보건학회 · 한국환경보건학회지2021 · 제47권 제5호사고대비물질 개인보호구 선정에 관한 연구(1): 물질유해성 및 작업위해성 분석김종일, 김청수, 정상태, 조용성, 한돈희한국환경보건학회 · 한국환경보건학회지2016 · 제42권 제6호노출 모델의 화평법 적용성: ECETOC TRA와 Stoffenmanager Tier 1 노출 모델을 활용한 벤젠의 작업자 노출 평가김기태, 나진성, 문준식, 옥정원, 정욱현한국환경보건학회 · 한국환경보건학회지2018 · 제44권 제5호사고대비물질 개인보호구 선정에 관한 연구(2): 노출위해성 매트릭스에 의한 분석김종일, 김청수, 정상태, 조용성, 한돈희한국환경보건학회 · 한국환경보건학회지2016 · 제42권 제6호

이 간행물의 다른 논문 (9건)