어린이 주요활동공간 중 소규모학원 내 유해물질 노출 평가
Exposure Assessment of Hazardous Substances in Small Academy of Children’s Activity Zones
2
조회
0
다운로드
3
인용
0
참고문헌
키워드
초록
Objectives: This study was conducted to identify hazardous factors that reflect the characteristics of the academy and to provide basic data of environmental safety standard. Methods: Heavy metals, volatile organic compounds, formaldehyde, pesticides and phthalates were measured in 20 academies, which were supplementary, music, art and physical education institutes. Results: In case of heavy metals, the 12 locations were detected for lead (Pb) over the standard value, and 15 locations were exceeded for the total heavy metal. In six locations, the concentrations of volatile organic compounds were exceeded the standard value of 400 µg/m 3 , and two locations for formaldehyde were exceeded the standard value of 100 µg/m 3 . The most commonly detected agents in the air dust were chlorpyrifos and diazinon. The concentrations of DEHP, DINP, and DBP were detected and exceeded in several academies, The risk assessment results showed that HCHO as carcinogen had a safety level of 10-7 to 10-6, and DEHP and DINP as non-carcinogens had a safety level as assessed to be under than 0.1. Conclusions: Through the investigation of long-term environmental and health effects related laws on academies, indoor air quality management might be needed because there were cases of exceeding standard.
Abstract
Objectives: This study was conducted to identify hazardous factors that reflect the characteristics of the academy and to provide basic data of environmental safety standard. Methods: Heavy metals, volatile organic compounds, formaldehyde, pesticides and phthalates were measured in 20 academies, which were supplementary, music, art and physical education institutes. Results: In case of heavy metals, the 12 locations were detected for lead (Pb) over the standard value, and 15 locations were exceeded for the total heavy metal. In six locations, the concentrations of volatile organic compounds were exceeded the standard value of 400 µg/m 3 , and two locations for formaldehyde were exceeded the standard value of 100 µg/m 3 . The most commonly detected agents in the air dust were chlorpyrifos and diazinon. The concentrations of DEHP, DINP, and DBP were detected and exceeded in several academies, The risk assessment results showed that HCHO as carcinogen had a safety level of 10-7 to 10-6, and DEHP and DINP as non-carcinogens had a safety level as assessed to be under than 0.1. Conclusions: Through the investigation of long-term environmental and health effects related laws on academies, indoor air quality management might be needed because there were cases of exceeding standard.
참고문헌 (19)
- 강승아, "인천지역 공공 노인복지시설의 건축조건과 실내공기질에 대한 실태조사 및 분석", KIEAE Journal, 9(2), pp.59~64 (2009), 한국생태환경건축학회
- 김호현, "일부 미적용 다중이용시설 및 사회복지시설의 휘발성유기화합물 노출로 인한 건강위해성평가", 한국실내환경학회지, 4(1), pp.42~52 (2007), 한국실내환경학회
- 정경식, "학원시설 실내공기질과 이용자의 자각증상에 관한 연구", 한국환경보건학회지, 35(6), pp.468~477 (2009), 한국환경보건학회
- Ministry of Environment Korea, "Indoor air quality control in public-use facilities, etc. act, Article 2" (2016)
- 양지연, "일부 미적용 다중이용시설의 실내 공기 중 알데히드류 및 휘발성유기화합물 노출로 인한 건강위해성 평가", 한국환경과학회지, 17(1), pp.45~56 (2008), 한국환경과학회
- Chan C.Y, "Volatile organic compounds in roadside microenvironments of metropolitan Hong Kong", Atom. Environ., 36, pp.2039~2047 (2002)[DOI]
- 배상근, "캠프캐럴 인근 주민에서 다이옥신류 및 유기염소계 농약의 혈중 농도 및 노출력", 한국산업보건학회지, 26(3), pp.277~285 (2016), 한국산업보건학회[DOI]
- Fenske RA, "Assessment of organophosphorous pesticide exposures in the diets of preschool children in Washington State", J Expo Anal Environ Epidemiol, 12(1), pp.21~28 (2002)[DOI]
- Hosie S, "Is there a correlation between organochlorine compounds and undescended testes?", Eur J Pediatr Surg, 10(5), pp.304~309 (2000)[DOI]
- Cooke JA, "Lead, zinc, cadmium and fluoride in small mammals from contaminated grassland established on fluorspar tailings", Water Air Soil Poll, 50(1-2), pp.43~54 (1990)
- Sathyanarayana S, "Baby care products: possible sources of infant phthalate exposure", Pediatrics, 121(2), pp.e260~e268 (2008)[DOI]
- 조명행, "Comparative study of PM2.5-and PM10-induced oxidative stress in rat lung epithelial cells", Journal of Veterinary Science, 5(1), pp.11~18 (2004), 대한수의학회
- Elliott CT, "Burden of mortality due to ambient fine particulate air pollution (PM2.5) in interior and Northern BC", Can J Public Health, 102(5), pp.390~393 (2011)
- 배현주, "서울시 미세먼지(PM10)와 초미세먼지(PM2.5)의 단기노출로 인한 사망영향", 한국환경보건학회지, 40(5), pp.346~354 (2014), 한국환경보건학회[DOI]
- 김호현, "초등학교와 학원 실내 공간의 금속 원소류 다경로 노출에 의한 건강 위해성 평가", 한국실내환경학회지, 9(3), pp.213~228 (2012), 한국실내환경학회
- 김호현, "어린이 주요활동공간의 휘발성유기화합물류 노출로 인한 건강위해성 평가 - 초등학교 및 학원을 중심으로", 한국실내환경학회지, 8(4), pp.263~274 (2011), 한국실내환경학회
- 김호현, "초등학교 및 학원 실내 공간 내 알데히드류 노출로 인한 건강위해성 평가", 한국실내환경학회지, 9(1), pp.19~31 (2012), 한국실내환경학회
- American Conference of Governmental Industrial Hygienists, "Threshold Limit Values for Chemical Substances and Physical Agents and Biological Exposure Indices", pp.5~ (2014)
- 김호현, "어린이 활동공간의 프탈레이트류 노출로 인한 건강 위해성 평가 : 초등학교와 학원을 중심으로", 한국실내환경학회지, 9(4), pp.367~381 (2012), 한국실내환경학회