접착제 취급 작업장 내 공기정화 설비를 이용한 휘발성 유기화합물 저감 평가
Assessment of Volatile Organic Compound Reduction Using an Air Purification Facility in an Adhesive Handling Process
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Background: Exposure to volatile organic compounds (VOCs) can have acute and chronic health effects on human beings in general and in working environments. In particular, VOCs are often emitted in large quantities in industrial settings. In such circumstances, there is a need to improve the indoor air quality at workplaces. Objectives: The purposes of this study were to verify the effectiveness of air cleaning devices in workplaces and provide alternative solutions for improving working environments. Methods: Personal exposure and area level of VOCs for workers were evaluated in a car-part adhesive process before and after installing an air cleaning device with a TiO2-coated filter. Passive samplers and direct reading instruments were used to collect and analyze the VOCs, and the removal efficiency and improvement of air quality were evaluated. We also calculated the exposure index (EI) to assess the risk level in the workplace. Results: The removal efficiency for VOCs through the installation of the air cleaning device was approximately 26.9~69.0% as determined by the concentration levels before and after installation. The measured substances did not exceed the exposure limits for the work environment and the EI was less than 1. However, carcinogenic substances such as benzene, formaldehyde, carbon tetrachloride, and trichloroethylene were detected. Conclusions: The application of an air cleaning device can be a solution for controlling the indoor air quality in a workplace, particularly in cases where ventilation systems cannot be installed due to process limitations.
Abstract
Background: Exposure to volatile organic compounds (VOCs) can have acute and chronic health effects on human beings in general and in working environments. In particular, VOCs are often emitted in large quantities in industrial settings. In such circumstances, there is a need to improve the indoor air quality at workplaces. Objectives: The purposes of this study were to verify the effectiveness of air cleaning devices in workplaces and provide alternative solutions for improving working environments. Methods: Personal exposure and area level of VOCs for workers were evaluated in a car-part adhesive process before and after installing an air cleaning device with a TiO2-coated filter. Passive samplers and direct reading instruments were used to collect and analyze the VOCs, and the removal efficiency and improvement of air quality were evaluated. We also calculated the exposure index (EI) to assess the risk level in the workplace. Results: The removal efficiency for VOCs through the installation of the air cleaning device was approximately 26.9~69.0% as determined by the concentration levels before and after installation. The measured substances did not exceed the exposure limits for the work environment and the EI was less than 1. However, carcinogenic substances such as benzene, formaldehyde, carbon tetrachloride, and trichloroethylene were detected. Conclusions: The application of an air cleaning device can be a solution for controlling the indoor air quality in a workplace, particularly in cases where ventilation systems cannot be installed due to process limitations.
참고문헌 (44)
- World Health Organization (WHO), "Indoor air quality: organic pollutants", Report on a WHO meeting (1989), WHO
- Finlayson-Pitts BJ, "Tropospheric air pollution : ozone, airborne toxics, polycyclic aromatic hydrocarbons, and particles", Science, 276(5315), pp.1045~1052 (1997)
- Otto DA, "Exposure of humans to a volatile organic mixture. I. Behavioral assessment", Arch Environ Health, 47(1), pp.23~30 (1992)
- "Volatile organic compounds' impact on indoor air quality"[URL]
- Shuai J, "Health risk assessment of volatile organic compounds exposure near Daegu dyeing industrial complex in South Korea", BMC Public Health, 18(1), pp.528~ (2018)
- Axelsson G, "Cancer incidence in a petrochemical industry area in Sweden", Sci Total Environ, 408(20), pp.4482~4487 (2010)
- Guo H, "Risk assessment of exposure to volatile organic compounds in different indoor environments", Environ Res, 94(1), pp.57~66 (2004)
- Kim PH, "A trend of VOC (volatile organic compound) control and patent analysis on the VOC control technical", Paper presented at: the 2007 SAREK Winter Conference, pp.132~135 (2007), The Society of Air-conditioning and Refrigerating Engineers of Korea
- Yu D, "Characteristics of photocatalytic degradation of isopropyl alcohol on TiO2-coated aluminium plate", Theor Appl Chem Eng, 11(1), pp.1039~1042 (2005)
- Zhang Y, "Can commonly-used fan-driven air cleaning technologies improve indoor air quality? A literature review", Atmos Environ(1994), 45(26), pp.4329~4343 (2011)
- 이기연, "코팅 룸 배기시스템 수치해석 및 성능개선에 대한 연구", 한국산학기술학회논문지, 14(5), pp.2086~2091 (2013), 한국산학기술학회[DOI]
- 김태영, "광촉매공정과 필터를 이용한 흡연부스 공기정화연구", 공업화학, 27(4), pp.433~438 (2016), 한국공업화학회
- Slimen H, "Photocatalytic decomposition of cigarette smoke using a TiO2-impregnated titanium mesh filter", Ind Eng Chem Res, 51(1), pp.587~590 (2012)
- Guo H, "Evaluation of total volatile organic compound emissions from adhesives based on chamber tests", J Air Waste Manag Assoc, 50(2), pp.199~206 (2000)
- Zhao Z, "Characterizing key volatile pollutants emitted from adhesives by chemical compositions, odor contributions and health risks", Molecules, 27(3), pp.1125~ (2022)
- Gupta R, "Investigating the relationship between indoor environment and workplace productivity in naturally and mechanically ventilated office environments", Build Serv Eng Res Technol, 41(3), pp.280~304 (2020)
- Woo WG, "A survey on the actual state of local exhaust ventilation system in small business I-awareness research on management system of local exhaust ventilation-", J Korea Soc Environ Adm, 15(2), pp.55~65 (2009)
- Alghamdi MA, "Seasonal and diurnal variations of BTEX and their potential for ozone formation in the urban background atmosphere of the coastal city Jeddah, Saudi Arabia", Air Qual Atmos Health, 7(4), pp.467~480 (2014)
- Choo ST, "Removal technologies of odor and volatile organic compounds from industrial processes", J Korean Soc Ind Appl, 7(3), pp.289~297 (2004)
- "Work environment measurement and analysis technical guideline"[URL]
- American Conference of Governmental Industrial Hygienists (ACGIH), "2017 TLVs and BEIs: Based on the documentation of the threshold limit values for chemical substances and physical agents & biological exposure indices", ACGIH, ~ (2017)
- 최세영, "A Development of Polyester-based Non-woven Fabric Filter for Air Purifier Treated with Self-actuated Photocatalyst", 엘라스토머 및 콤포지트, 51(3), pp.226~232 (2016), 한국고무학회
- "PID correction factors"[URL]
- Yang WH, "Organic solvent exposure of thinner-using occupation and its treatment by means of TiO2 photocatalyst", Korean J Sanit, 17(2), pp.26~33 (2002)
- 유성준, "CFD 해석을 이용한 소규모 인쇄 작업장의 환기방식 및 환기량에 따른 환기효율 평가에 관한 연구", 대한건축학회논문집, 29(06), pp.263~270 (2013), 대한건축학회
- 길국호, "산업재해에서의 개인보호구 특성 분석", 대한인간공학회지, 36(6), pp.753~764 (2017), 대한인간공학회[DOI]
- Choi J, "Occupational health management for heavy metals", Korean Assoc Occup Health Nurs, 9(2), pp.26~31 (2002)
- Lee GD, "A study of air freshing by UV lamp and TiO2 catalyst", Paper presented at: the 2011 Safety Management and Science Spring Conference, pp.205~227 (2011), Korea Safety Management & Science
- 남기복, "실내오염물질 제거용 광촉매의 제조조건에 따른 반응활성 연구", Clean Technology, 22(2), pp.106~113 (2016), 한국청정기술학회
- 이찬, "도장공정 배기가스 내 VOC 처리를 위한 활성탄-광촉매 복합시스템", 에너지공학, 14(2), pp.133~139 (2005), 한국에너지학회
- You JW, "Photocatalytic potential of a titanium dioxide–supported platinum catalyst against VOCs with complicated composition under varying humidity conditions", J Clean Prod, 371, pp.133487~ (2022)
- Lin Z, "Assessment of multiple environmental factors on the adsorptive and photocatalytic re-moval of gaseous formaldehyde by a nano-TiO2 colloid: experimental and simulation studies", J Colloid Interface Sci, 608(Pt 2), pp.1769~1781 (2022)
- Sohn J, "The risk assessment of hazard chemicals in environment", J Korean Soc Environ Eng, 29(5), pp.477~488 (2007)
- "List of classifications: Agents classified by the IARC monographs"[URL]
- Rushton L, "How much does benzene contribute to the overall burden of cancer due to occupation?", Chem Biol Interact, 184(1-2), pp.290~292 (2010)
- Lachenmeier DW, "The role of acetaldehyde outside ethanol metabolism in the carcinogenicity of alcoholic beverages : evidence from a large chemical survey", Food Chem Toxicol, 46(8), pp.2903~2911 (2008)
- Henderson L, "A review of the genotoxicity of ethylbenzene", Mutat Res, 635(2-3), pp.81~89 (2007)
- "Styrene"[URL]
- Win-Shwe TT, "Neurotoxicity of toluene", Toxicol Lett, 198(2), pp.93~99 (2010)
- Rajan ST, "Health hazards of xylene : a literature review", J Clin Diagn Res, 8(2), pp.271~274 (2014)
- 박태원, "건강근로자효과 보정 전후의 메타 분석 결과 비교-직업적 트리클로로에틸렌 노출과 암의 연관성-", 한국환경보건학회지, 40(5), pp.385~396 (2014), 한국환경보건학회[DOI]
- Kumagai S, "Relationship between cumulative exposure to 1, 2-dichloropropane and incidence risk of cholangiocarcinoma among offset printing workers", Occup Environ Med, 73(8), pp.545~552 (2016)
- Weber LW, "Hepatotoxicity and mechanism of action of haloalkanes : carbon tetrachloride as a toxicological model", Crit Rev Toxicol, 33(2), pp.105~136 (2003)
- Valdiviezo A, "Reanalysis of trichloroethylene and tetrachloroethylene metabolism to glutathione conjugates using human, rat, and mouse liver in vitro models to improve precision in risk characterization", Environ Health Perspect, 130(11), pp.117009~ (2022)