본문 바로가기
KERD
논문

CMIT/MIT 가습기살균제 사용에 따른 피해구제 신청자의 노출등급 및 노출특성 분석

Analysis of Exposure Characteristics and Exposure Rating of Participants with Injuries from CMIT/MIT Humidifier Disinfectants

6

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Background: The Korea Centers for Disease Control and Prevention (KCDC) has identified cases of people suspected of suffering lung disease potentially caused by chloromethylisothiazolinone/methylisothiazolinone (CMIT/MIT) used in humidifier disinfectants (HDs). The Korean Ministry of Environment (MoE) epidemiological investigation and toxicity test study found that HDs caused health damage such as asthma and lung disease. Objectives: The main purposes of this study were to classify the HD exposure rating and to analyze the exposure characteristics that affect exposure to CMIT/MIT HDs. Methods: The exposure characteristics and socio-demographic characteristics of victim participants using CMIT/MIT HDs were investigated through questionnaires. An inhalation no observed adverse effect level (NOAEL) for CMIT/MIT was produced based on inhalation toxicity values. Exposure ratings (class 1~class 2) were cross-tabulated with clinical ratings (acceptable~unacceptable). A correlation analysis was conducted with the main exposure characteristics that affect the exposure concentration of CMIT/MIT HDs. Results: The concentration in indoor air of CMIT/MIT was 8.75±25.40 μ g/m3, and the exposure concentration was 2.30±6.29 μg/m3. The CMIT/MIT exposure rating of 67 participants with high exposures of not more than MOE 100 were evaluated as 14.5%, while the damage participants who matched the clinical rating made up 4.5%. The exposure concentration of CMIT/MIT showed a positive correlation with the daily usage amount and usage frequency, and a negative correlation with volume of the indoor environment. Conclusions: A new exposure rating could be suggested and calculated based on the MOE, and the factors affecting the exposure concentration could be identified.

Abstract

Background: The Korea Centers for Disease Control and Prevention (KCDC) has identified cases of people suspected of suffering lung disease potentially caused by chloromethylisothiazolinone/methylisothiazolinone (CMIT/MIT) used in humidifier disinfectants (HDs). The Korean Ministry of Environment (MoE) epidemiological investigation and toxicity test study found that HDs caused health damage such as asthma and lung disease. Objectives: The main purposes of this study were to classify the HD exposure rating and to analyze the exposure characteristics that affect exposure to CMIT/MIT HDs. Methods: The exposure characteristics and socio-demographic characteristics of victim participants using CMIT/MIT HDs were investigated through questionnaires. An inhalation no observed adverse effect level (NOAEL) for CMIT/MIT was produced based on inhalation toxicity values. Exposure ratings (class 1~class 2) were cross-tabulated with clinical ratings (acceptable~unacceptable). A correlation analysis was conducted with the main exposure characteristics that affect the exposure concentration of CMIT/MIT HDs. Results: The concentration in indoor air of CMIT/MIT was 8.75±25.40 μ g/m3, and the exposure concentration was 2.30±6.29 μg/m3. The CMIT/MIT exposure rating of 67 participants with high exposures of not more than MOE 100 were evaluated as 14.5%, while the damage participants who matched the clinical rating made up 4.5%. The exposure concentration of CMIT/MIT showed a positive correlation with the daily usage amount and usage frequency, and a negative correlation with volume of the indoor environment. Conclusions: A new exposure rating could be suggested and calculated based on the MOE, and the factors affecting the exposure concentration could be identified.

참고문헌 (25)

  1. 황정행, "살균제가 필요 없는 가습기 디자인 연구 - 구조와 디자인을 중심으로 한 해결 방법 -", 디지털디자인학연구, 13(4), pp.569~578 (2013), 한국디지털디자인학회[DOI]
  2. Kim EC, "Analysis of affecting factors of lung disease according to exposure and socio-demographic characteristics in the affected victims by usage of humidifier disinfectants", pp.2021
  3. Use and care of home humidifiers, "U.S. Environmental Protection Agency (EPA)", EPA, ~, pp.Indoor air facts No. 8 (1991)
  4. Bae NR, "The effect of education and providing of environmental parameter on residents' management of indoor environment", pp.2006
  5. 류현수, "가습기살균제 사용에 따른 피해 신청자들의 특성 및 노출평가 오류 영향요인 분석", 한국환경보건학회지, 45(1), pp.71~81 (2019), 한국환경보건학회[DOI]
  6. 이혜림, "PHMG-Phosphate의 직업적 유해성평가를 통한 노출기준 제안 연구", 한국산업보건학회지, 29(1), pp.13~20 (2019), 한국산업보건학회[DOI]
  7. Yoon J, "Humidifier disinfectant consumption and humidifier disinfectant-associated lung injury in South Korea : a nationwide population-based study", Int J Environ Res Public Health, 18(11), pp.6136~ (2021)
  8. 김판기, "가습기살균제 피해자의 아픔을 줄일 수 있었다", 한국환경보건학회지, 48(1), pp.1~8 (2022), 한국환경보건학회
  9. 박동욱, "Chloromethylisothiazolinone (CMIT)과 Methylisothiazolinone (MIT)의 건강영향에 대한 고찰 - 가습기 살균제 폐 손상을 중심으로 -", 한국환경보건학회지, 46(3), pp.312~323 (2020), 한국환경보건학회[DOI]
  10. Establishing disease identification and standards criteria to expand the range of health hazards caused by the humidifier sterilizer, "Korean Society of Environmental Health and Toxicology", National Institute of Environmental Research, ~, pp.NIER-SP2016-429 (2017)
  11. Ministry of Environment, "2017 White paper of environment" (2017), Ministry of Environment;
  12. "Statistical data"[URL]
  13. 이슬아, "가습기살균제 환경노출 판정등급에 따른 개인 노출 특성 분포 - 4-1차와 4-2차 신청자를 중심으로", 한국환경보건학회지, 45(4), pp.370~380 (2019), 한국환경보건학회[DOI]
  14. 민기홍, "가습기살균제 피해신청자들의 노출등급 분류 및 폐질환 발생 영향요인 분석", 한국환경보건학회지, 48(6), pp.324~360 (2022), 한국환경보건학회[DOI]
  15. 김순신, "불산 누출사고에 따른 지역사회 구성원들의 노출평가", 한국환경보건학회지, 41(1), pp.1~10 (2015), 한국환경보건학회[DOI]
  16. "Toxic substance characterization and summary of toxicity and control information"[URL]
  17. "Reaction mass of 5-chloro-2-methyl4-isothiazolin-3-one and 2-methyl-2H -isothiazol-3-one"[URL]
  18. "Reregistration eligibility decision (RED) methylisothiazolinone. EPA738-R-98-012"[URL]
  19. Research on hazard and risk assessment and technical feasibility assessment of chemical substances with additional establishment of exposure cri-teria, "Occupational Safety and Health Research Institute", OSHRI, ~ (2017)
  20. Special Committee for Examining the Cause of Tragedy caused by Humidifier Disinfectant (SCECTHD), "Analysis of components of disinfectant contained in humidifier disinfectant products", SCECTHD, ~ (2020)
  21. 박진현, "시간활동양상 및 이산화탄소 농도를 이용한 한국 주택 환기량 추정", 한국환경보건학회지, 45(1), pp.1~8 (2019), 한국환경보건학회[DOI]
  22. Diapouli E, "Estimating the concentration of indoor particles of outdoor origin : a review", J Air Waste Manag Assoc, 63(10), pp.1113~1129 (2013)
  23. "Risk assessment guidance for superfund volume I: human health evaluation manual. (Part F, supplemental guidance for inhalation risk assessment). EPA540-R-070-002"[URL]
  24. Min GH, "Exposure and health risk assessment of active substance for disinfection workers and general public according to spraying COVID-19 disinfecting biocides", pp.2023
  25. 이승호, "국민환경보건기초조사 1~3기의 연구성과 검토", 한국환경보건학회지, 47(3), pp.227~244 (2021), 한국환경보건학회[DOI]

관련 논문AI추천

가습기살균제 피해신청자들의 노출등급 분류 및 폐질환 발생 영향요인 분석김동준, 류지윤, 민기홍, 배성호, 신정현, 신지훈, 양원호, 우재민, 이슬아, 정다영, 조은경, 최윤형한국환경보건학회 · 한국환경보건학회지2022 · 제48권 제6호Chloromethylisothiazolinone (CMIT)과 Methylisothiazolinone (MIT)의 건강영향에 대한 고찰 - 가습기 살균제 폐 손상을 중심으로 -권정환, 김지원, 류승훈, 박동욱, 박소영, 박지훈, 이소연한국환경보건학회 · 한국환경보건학회지2020 · 제46권 제3호일반 가구의 가습기살균제 노출 특성 및 건강이상 경험과의 연관성김솔휘, 김판기, 백도명, 이경무, 이은선, 임종한, 정해관한국환경보건학회 · 한국환경보건학회지2020 · 제46권 제3호가습기살균제 피해 신청자들의 인구학적 특성 및 노출평가 - 4-1차와 4-2차 신청자를 중심으로 -곽정현, 김판기, 류현수, 양원호, 윤정교, 이슬아, 최윤형, 추연희, 한보영한국환경보건학회 · 한국환경보건학회지2018 · 제44권 제4호가습기 살균제 건강 피해 조사에서 노출 평가 방법 고찰박동욱한국환경보건학회 · 한국환경보건학회지2018 · 제44권 제2호가습기 살균제 폐 손상 피해자의 살균제 노출 특성 -태아와 임산부 노출을 중심으로 -이은, 김선경, 노현석, 도경현, 류승훈, 박동욱, 배문주, 백도명, 신동천, 안종주, 임흥규, 조재림, 차원석, 최예용, 홍상범, 홍수종한국환경보건학회 · 한국환경보건학회지2016 · 제42권 제3호

이 간행물의 다른 논문 (4건)