CMIT/MIT 가습기살균제 사용에 따른 피해구제 신청자의 노출등급 및 노출특성 분석
Analysis of Exposure Characteristics and Exposure Rating of Participants with Injuries from CMIT/MIT Humidifier Disinfectants
6
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Background: The Korea Centers for Disease Control and Prevention (KCDC) has identified cases of people suspected of suffering lung disease potentially caused by chloromethylisothiazolinone/methylisothiazolinone (CMIT/MIT) used in humidifier disinfectants (HDs). The Korean Ministry of Environment (MoE) epidemiological investigation and toxicity test study found that HDs caused health damage such as asthma and lung disease. Objectives: The main purposes of this study were to classify the HD exposure rating and to analyze the exposure characteristics that affect exposure to CMIT/MIT HDs. Methods: The exposure characteristics and socio-demographic characteristics of victim participants using CMIT/MIT HDs were investigated through questionnaires. An inhalation no observed adverse effect level (NOAEL) for CMIT/MIT was produced based on inhalation toxicity values. Exposure ratings (class 1~class 2) were cross-tabulated with clinical ratings (acceptable~unacceptable). A correlation analysis was conducted with the main exposure characteristics that affect the exposure concentration of CMIT/MIT HDs. Results: The concentration in indoor air of CMIT/MIT was 8.75±25.40 μ g/m3, and the exposure concentration was 2.30±6.29 μg/m3. The CMIT/MIT exposure rating of 67 participants with high exposures of not more than MOE 100 were evaluated as 14.5%, while the damage participants who matched the clinical rating made up 4.5%. The exposure concentration of CMIT/MIT showed a positive correlation with the daily usage amount and usage frequency, and a negative correlation with volume of the indoor environment. Conclusions: A new exposure rating could be suggested and calculated based on the MOE, and the factors affecting the exposure concentration could be identified.
Abstract
Background: The Korea Centers for Disease Control and Prevention (KCDC) has identified cases of people suspected of suffering lung disease potentially caused by chloromethylisothiazolinone/methylisothiazolinone (CMIT/MIT) used in humidifier disinfectants (HDs). The Korean Ministry of Environment (MoE) epidemiological investigation and toxicity test study found that HDs caused health damage such as asthma and lung disease. Objectives: The main purposes of this study were to classify the HD exposure rating and to analyze the exposure characteristics that affect exposure to CMIT/MIT HDs. Methods: The exposure characteristics and socio-demographic characteristics of victim participants using CMIT/MIT HDs were investigated through questionnaires. An inhalation no observed adverse effect level (NOAEL) for CMIT/MIT was produced based on inhalation toxicity values. Exposure ratings (class 1~class 2) were cross-tabulated with clinical ratings (acceptable~unacceptable). A correlation analysis was conducted with the main exposure characteristics that affect the exposure concentration of CMIT/MIT HDs. Results: The concentration in indoor air of CMIT/MIT was 8.75±25.40 μ g/m3, and the exposure concentration was 2.30±6.29 μg/m3. The CMIT/MIT exposure rating of 67 participants with high exposures of not more than MOE 100 were evaluated as 14.5%, while the damage participants who matched the clinical rating made up 4.5%. The exposure concentration of CMIT/MIT showed a positive correlation with the daily usage amount and usage frequency, and a negative correlation with volume of the indoor environment. Conclusions: A new exposure rating could be suggested and calculated based on the MOE, and the factors affecting the exposure concentration could be identified.
참고문헌 (25)
- 황정행, "살균제가 필요 없는 가습기 디자인 연구 - 구조와 디자인을 중심으로 한 해결 방법 -", 디지털디자인학연구, 13(4), pp.569~578 (2013), 한국디지털디자인학회[DOI]
- Kim EC, "Analysis of affecting factors of lung disease according to exposure and socio-demographic characteristics in the affected victims by usage of humidifier disinfectants", pp.2021
- Use and care of home humidifiers, "U.S. Environmental Protection Agency (EPA)", EPA, ~, pp.Indoor air facts No. 8 (1991)
- Bae NR, "The effect of education and providing of environmental parameter on residents' management of indoor environment", pp.2006
- 류현수, "가습기살균제 사용에 따른 피해 신청자들의 특성 및 노출평가 오류 영향요인 분석", 한국환경보건학회지, 45(1), pp.71~81 (2019), 한국환경보건학회[DOI]
- 이혜림, "PHMG-Phosphate의 직업적 유해성평가를 통한 노출기준 제안 연구", 한국산업보건학회지, 29(1), pp.13~20 (2019), 한국산업보건학회[DOI]
- Yoon J, "Humidifier disinfectant consumption and humidifier disinfectant-associated lung injury in South Korea : a nationwide population-based study", Int J Environ Res Public Health, 18(11), pp.6136~ (2021)
- 김판기, "가습기살균제 피해자의 아픔을 줄일 수 있었다", 한국환경보건학회지, 48(1), pp.1~8 (2022), 한국환경보건학회
- 박동욱, "Chloromethylisothiazolinone (CMIT)과 Methylisothiazolinone (MIT)의 건강영향에 대한 고찰 - 가습기 살균제 폐 손상을 중심으로 -", 한국환경보건학회지, 46(3), pp.312~323 (2020), 한국환경보건학회[DOI]
- Establishing disease identification and standards criteria to expand the range of health hazards caused by the humidifier sterilizer, "Korean Society of Environmental Health and Toxicology", National Institute of Environmental Research, ~, pp.NIER-SP2016-429 (2017)
- Ministry of Environment, "2017 White paper of environment" (2017), Ministry of Environment;
- "Statistical data"[URL]
- 이슬아, "가습기살균제 환경노출 판정등급에 따른 개인 노출 특성 분포 - 4-1차와 4-2차 신청자를 중심으로", 한국환경보건학회지, 45(4), pp.370~380 (2019), 한국환경보건학회[DOI]
- 민기홍, "가습기살균제 피해신청자들의 노출등급 분류 및 폐질환 발생 영향요인 분석", 한국환경보건학회지, 48(6), pp.324~360 (2022), 한국환경보건학회[DOI]
- 김순신, "불산 누출사고에 따른 지역사회 구성원들의 노출평가", 한국환경보건학회지, 41(1), pp.1~10 (2015), 한국환경보건학회[DOI]
- "Toxic substance characterization and summary of toxicity and control information"[URL]
- "Reaction mass of 5-chloro-2-methyl4-isothiazolin-3-one and 2-methyl-2H -isothiazol-3-one"[URL]
- "Reregistration eligibility decision (RED) methylisothiazolinone. EPA738-R-98-012"[URL]
- Research on hazard and risk assessment and technical feasibility assessment of chemical substances with additional establishment of exposure cri-teria, "Occupational Safety and Health Research Institute", OSHRI, ~ (2017)
- Special Committee for Examining the Cause of Tragedy caused by Humidifier Disinfectant (SCECTHD), "Analysis of components of disinfectant contained in humidifier disinfectant products", SCECTHD, ~ (2020)
- 박진현, "시간활동양상 및 이산화탄소 농도를 이용한 한국 주택 환기량 추정", 한국환경보건학회지, 45(1), pp.1~8 (2019), 한국환경보건학회[DOI]
- Diapouli E, "Estimating the concentration of indoor particles of outdoor origin : a review", J Air Waste Manag Assoc, 63(10), pp.1113~1129 (2013)
- "Risk assessment guidance for superfund volume I: human health evaluation manual. (Part F, supplemental guidance for inhalation risk assessment). EPA540-R-070-002"[URL]
- Min GH, "Exposure and health risk assessment of active substance for disinfection workers and general public according to spraying COVID-19 disinfecting biocides", pp.2023
- 이승호, "국민환경보건기초조사 1~3기의 연구성과 검토", 한국환경보건학회지, 47(3), pp.227~244 (2021), 한국환경보건학회[DOI]
