Contrast Enhanced Cerebral MR Venography: Comparison between Arterial and Venous Triggering Methods
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Purpose : To compare the arterial and venous detection sites of triggering methods in contrast-enhanced-MR-venography (CE-MRV) for the evaluation of intracranial venous system. Materials and Methods: 41 healthy patients underwent CE-MRV with autotriggering at either the cavernous segment of internal carotid artery with an inserted time-delay of 6 seconds (n = 20) or the superior sagittal sinus without any timedelay (n = 21). 0.1 mmol/kg gadolinium-based contrast material (Magnevist, Schering, Germany) was intravenously injected by hand injection. A sagittal fast-spoiled-gradient-echo-sequence ranging from one ear to the other was performed (TR/TE5.2/1.5, Matrix 310×310, 124 sections in the 15-cm-thick volume). 17 predefined venous structures were evaluated on all venograms by two neuroradiologists and defined as completely visible, partially visible, or none visible. Results: The rate of completely visible structures were 272 out of 323 (84%) in the arterial triggering CE-MRV and 310out of 340 (91%) in the venous triggering CE-MRV. The venous triggering CE-MRV demonstrated an overall superior visualization of the cerebral veins than the arterial triggering CE-MRV (Fisher exact test, p < 0.006). Conclusion: CE-MRV using venous autotriggering method provides higher-quality images of the intracranial venous structures compared to that of arterial.
Abstract
Purpose : To compare the arterial and venous detection sites of triggering methods in contrast-enhanced-MR-venography (CE-MRV) for the evaluation of intracranial venous system. Materials and Methods: 41 healthy patients underwent CE-MRV with autotriggering at either the cavernous segment of internal carotid artery with an inserted time-delay of 6 seconds (n = 20) or the superior sagittal sinus without any timedelay (n = 21). 0.1 mmol/kg gadolinium-based contrast material (Magnevist, Schering, Germany) was intravenously injected by hand injection. A sagittal fast-spoiled-gradient-echo-sequence ranging from one ear to the other was performed (TR/TE5.2/1.5, Matrix 310×310, 124 sections in the 15-cm-thick volume). 17 predefined venous structures were evaluated on all venograms by two neuroradiologists and defined as completely visible, partially visible, or none visible. Results: The rate of completely visible structures were 272 out of 323 (84%) in the arterial triggering CE-MRV and 310out of 340 (91%) in the venous triggering CE-MRV. The venous triggering CE-MRV demonstrated an overall superior visualization of the cerebral veins than the arterial triggering CE-MRV (Fisher exact test, p < 0.006). Conclusion: CE-MRV using venous autotriggering method provides higher-quality images of the intracranial venous structures compared to that of arterial.
참고문헌 (19)
- Farb RI, "The dural venous sinuses: normal intraluminal architecture defined on contrast-enhanced MR venography", Neuroradiology, 49, pp.727~732 (2007)
- Farb RI, "terBrugge KG. Intracranial venous system: gadoliniumenhanced three-dimensional MR venography with autotriggered elliptic centric-ordered sequence--initial experience", Radiology, 226, pp.203~209 (2003)
- Kirchhof K, "More reliable noninvasive visualization of the cerebral veins and dural sinuses: comparison of three MR angiographic techniques", Radiology, 224, pp.804~810 (2002)
- Liang L, "Evaluation of the intracranial dural sinuses with a 3D contrast-enhanced MP-RAGE sequence: prospective comparison with 2D-tof MR venography and digital subtraction angiography", AJNR Am J Neuroradiol, 22, pp.481~492 (2001)
- Lovblad KO, "Fast contrastenhanced MR whole-brain venography", Neuroradiology, 44, pp.681~688 (2002)
- Meckel S, "Display of dural sinuses with time-resolved, contrast-enhanced three-dimensional MR venography", Cerebrovasc Dis, 25, pp.217~224 (2008)
- Mermuys KP, "Threedimensional venography of the brain with a volumetric interpolated sequence", Radiology, 234, pp.901~908 (2005)
- Rollins N, "Cerebral MR venography in children: comparison of 2D time-of-flight and gadoliniumenhanced 3D gradient-echo techniques", Radiology, 235, pp.1011~1017 (2005)
- Wetzel SG, "Imaging of the intracranial venous system with a contrastenhanced volumetric interpolated examination", Eur Radiol, 13, pp.1010~1018 (2003)
- Klingebiel R, "Comparative evaluation of 2D time-of-flight and 3D elliptic centric contrast-enhanced MR venography in patients with presumptive cerebral venous and sinus thrombosis", Eur J Neurol, 14, pp.139~143 (2007)
- Leach JL, "Partially recanalized chronic dural sinus thrombosis: findings on MR imaging, timeof- flight MR venography, and contrast-enhanced MR venography", AJNR Am J Neuroradiol, 28, pp.782~789 (2007)
- Bozzao A, "Role of contrastenhanced MR venography in the preoperative evaluation of parasagittal meningiomas", Eur Radiol, 15, pp.1790~1796 (2005)
- Mattle HP, "Cerebral venography with MR", Radiology, 178, pp.453~458 (1991)
- Kanal E, "Safety considerations in MR imaging", Radiology, 176, pp.593~606 (1990)
- Talagala SL, "Fast three-dimensional time-of-flight MR angiography of the intra-cranial vasculature", J Magn Reson Imaging, 5, pp.317~323 (1995)
- Liauw L, "MR angiography of the intracranial venous system", Radiology, 214, pp.678~682 (2000)
- Farb RI, "Intracranial venous system: gadoliniumenhanced three-dimensional MR venography with autotriggered elliptic centric-ordered sequence-initial experience", Radiology, 226, pp.203~209 (2003)
- Fu JH, "Comparison of real-time threedimensional gadolinium-enhanced elliptic centric-ordered MR venography and two-dimensional time-of-flight MR venography of the intracranialvenous system", J Chin Med Assoc, 73, pp.131~138 (2010)
- 19. Marcello M, "Multiple sclerosis: cerebral circulation time", Radiology, 262, pp.947~955 (2012)
