Keyhole Imaging Combined Phase Contrast MR Angiography Technique
2
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Phase Contrast MR Angiography(PC MRA) is excellent MRA technique for measuring the velocity of vessels in the human body. PC MRA need to at least four images for angiogram reconstruction and it caused longer scan time. Therefore, we used keyhole imaging combined PC MRA to reduce the scan time. However, keyhole imaging can lead the erroneous effects as loss of phase information or frequency discontinuous. In this study, we applied the keyhole imaging combined 2D PC MRA for improving the temporal resolution and also measured the velocity to evaluate the accuracy of phase information. We used 0.32T MRI scanner(Magfinder II, Scimedix, Korea). Using the 2D PC MRA pulse sequence, the vascular images for a human brain targeted on the Superior Sagittal Sinus(SSS)were obtained. We applied tukey window function for keyhole images to minimize the ringing artifact and erroneous factors that are induced frequency discontinuous and phase information loss. We also applied zero-padded algorithm to peripheral missing k-space lines to compare keyhole imaging results and the artifact power(AP) value was measured on the complex difference images to validate the image quality. Consider as based on our results, heavy image distortions and artifacts were shown until using at least 50% keyhole factor. Using above the 50% keyhole factors are shown well reconstructed and matched for magnitude images and velocity information measurements. In conclusion,we confirmed the image quality and velocity information of keyhole technique combined 2D PC MRA. Especially,measured velocity information through the keyhole imaging combination was similar to the velocity information of full sampled k-space image despite of frequency discontinuous and phase information loss in the keyhole imaging reconstruction process. Consequently, the keyhole imaging combined 2D PC MRA will give some clinical usefulness and advantages as improving the temporal resolution and measuring the velocity information via selecting the appropriate keyhole factor at low tesla MRI system.
Abstract
Phase Contrast MR Angiography(PC MRA) is excellent MRA technique for measuring the velocity of vessels in the human body. PC MRA need to at least four images for angiogram reconstruction and it caused longer scan time. Therefore, we used keyhole imaging combined PC MRA to reduce the scan time. However, keyhole imaging can lead the erroneous effects as loss of phase information or frequency discontinuous. In this study, we applied the keyhole imaging combined 2D PC MRA for improving the temporal resolution and also measured the velocity to evaluate the accuracy of phase information. We used 0.32T MRI scanner(Magfinder II, Scimedix, Korea). Using the 2D PC MRA pulse sequence, the vascular images for a human brain targeted on the Superior Sagittal Sinus(SSS)were obtained. We applied tukey window function for keyhole images to minimize the ringing artifact and erroneous factors that are induced frequency discontinuous and phase information loss. We also applied zero-padded algorithm to peripheral missing k-space lines to compare keyhole imaging results and the artifact power(AP) value was measured on the complex difference images to validate the image quality. Consider as based on our results, heavy image distortions and artifacts were shown until using at least 50% keyhole factor. Using above the 50% keyhole factors are shown well reconstructed and matched for magnitude images and velocity information measurements. In conclusion,we confirmed the image quality and velocity information of keyhole technique combined 2D PC MRA. Especially,measured velocity information through the keyhole imaging combination was similar to the velocity information of full sampled k-space image despite of frequency discontinuous and phase information loss in the keyhole imaging reconstruction process. Consequently, the keyhole imaging combined 2D PC MRA will give some clinical usefulness and advantages as improving the temporal resolution and measuring the velocity information via selecting the appropriate keyhole factor at low tesla MRI system.
참고문헌 (24)
- V.M. Pai, "Phase contrast using multiecho steady-state free precession", Mag Reson Med, 58(2), pp.419~424 (2007)
- J. Huston III, "Comparison of Time-of- Flight and Phase-Contrast MR neuroaniograpic techniques", Radiographics, 13(1), pp.5~19 (1993)
- J.V. Velikina, "PC HYPR flow: A technique for rapid imaging of contrast dynamics", J Magn Reson Imaging, 31(2), pp.447~456 (2010)
- J.R. Pernicone, "Three-Dimensional Phase-Contrast MR Angiography in the Head and Neck: Preliminary Report", Am J Roentgenol, 155(1), pp.167~176 (1990)
- C.L. Dumoulin, "Three-dimensional Phase Contrast Angiography", MagnReson Imaging, 9(1), pp.139~149 (1989)
- R. Hausmann, "Phase-Contrast MR Angiography with Reduced Acquisition Time: New Concepts in Sequence Design", J Magn Reson Imaging, 1(4), pp.415~422 (1991)
- J.J. Van Vaals, "Keyhole method for accelerating imaging of contrast agent uptake", J Magn Reson Imaging, 3(4), pp.671~675 (1993)
- J. Beranek-Chiu, "Improved vessel delineation in keyhole time-resolved contrast-enhanced MR angiography using a gadolinium doped flush", J Magn Reson Imaging, 29(5), pp.1147~1153 (2009)
- J.E. Bishop, "Limitations of the keyhole technique for quantitative dynamic contrast- enhanced breast MRI", J Magn Reson Imaging, 7(4), pp.716~723 (1997)
- T.A. Sparaggins, "Simulation of spatial and contrast distortions in keyhole imaging", Magn Reson Med, 31(3), pp.320~322 (1994)
- X. Hu, "On the 'keyhole' technique", J Magn Reson Imaging, 4(2) (1994)
- S.O. Schoenberg, "Parallel imaging in Clinical MR Applications", pp.91~103 (2007), Springer
- J. Xiong, "The effects of k-space data undersampling and discontinuities in keyhole functional MRI", Magn Reson Imaging, 17(1), pp.109~119 (1999)
- S.W. Sun, "Keyhole and zero-padding approaches for reduced-encoding diffusion tensor imaging of the mouse brains", Magn Reson Imaging, 28(10), pp.1413~1419 (2010)
- S. Heiland, "Does the 'keyhole' technique improve spatial resolution in MRI perfusion measurements? A study in volunteers", Neuroradiology, 43(7), pp.518~524 (2001)
- C. Oesterle, "Benefits and pitfalls of keyhole imaging, especially in first-pass perfusion studies", J Magn Reson Imaging, 11(3), pp.312~323 (2000)
- R.H. Hashemi, "MRI The Basics, 3rd ed", Lippincott Williams & Wilkins, pp.146~163 (2010)
- D.W. McRobbie, "MRI From Picture to Proton, 2nd ed", pp.108~136 (2004), Cambridge Univ. Press
- M.A. Bernstein, "Handbook of MRI Pulse Sequence", pp.494~499 (2007), Elsevier Academic Press
- A.S. Nencka, "Apodization and smoothing alter voxel time series correlations", in Proc. 16th Intl Soc Mag Reson Med, pp.2457~ (2008)
- J.C. Kaimal, "Time series tapering for short data samples", Bound Layer Meteor, 57(1), pp.187~194 (1991)
- M.A. Bernstein, "Effect of windowing and zero-filled reconstruction of MRI data on spatial resolution and acquisition strategy", J Magn Reson Imaging, 14(3), pp.270~280 (2001)
- Jim X, "PULSAR: A MATLAB Toolbox for Parallel Magnetic Resonance Imaging Using Array Coils and Multiple Channel Receivers", Concepts Magn Reson Part B, 31(1), pp.24~36 (2007)
- X. Liu, "Self-calibrating coil sensitivity profiles for parallel imaging based on anisotropic diffusion", J Multimedia, 5(6), pp.580~587 (2010)