Purpose: This study proposes a novel method to reduce N/2 ghosting artifacts and eddy current-induced image shifts in single-shot diffusion-weighted echo-planar imaging (DW-EPI) for 7 tesla (T) MRI. This method integrates dummy diffusion gradients and optimized navigator echo placement to improve phase correction and artifact reduction, addressing the limitations of conventional phase correction methods. Materials and Methods: The proposed method was compared to the conventional approach, which uses Nav1 for phase correction without dummy diffusion gradients. The new approach incorporates Nav2 for phase correction and dummy diffusion gradients to mitigate eddy current effects. Phantom and in vivo experiments were conducted to evaluate the N/2 ghosting intensity, phase stability, and geometric accuracy. In vivo diffusion- weighted images were acquired at b = 1000 s/mm2 and the effectiveness of the phase correction was qualitatively and quantitatively assessed. Results: Phase evolution analysis revealed that Nav2 more accurately captures diffusion gradient-induced phase perturbations compared to Nav1, leading to improved N/2 ghosting artifact correction. Phantom experiments demonstrated a 41% reduction in N/2 ghosting artifacts using Nav2 compared to Nav1, confirming its superior phase correction capabilities. The in vivo results showed that the proposed method reduced ghosting artifacts and image shifts, leading to an improved alignment of diffusion-weighted images with the reference b = 0 image. Furthermore, the inclusion of dummy diffusion gradients further reduced eddy current-induced artifacts, enhancing image stability and tissue contrast in high-field diffusion-weighted imaging. Conclusion: The proposed method of integrating Nav2 for phase correction and dummy diffusion gradients significantly reduced N/2 ghosting artifacts and geometric distortions in high-field diffusion MRI. These findings suggest that optimizing navigator positioning and incorporating dummy diffusion gradients can enhance the phase stability and improve the reliability of DW-EPI at 7 T. However, as this was a preliminary study with a limited in vivo dataset (n = 2), further validation with larger datasets, different MRI systems, and broader imaging conditions is necessary to fully assess its robustness and clinical applicability.

Abstract

Purpose: This study proposes a novel method to reduce N/2 ghosting artifacts and eddy current-induced image shifts in single-shot diffusion-weighted echo-planar imaging (DW-EPI) for 7 tesla (T) MRI. This method integrates dummy diffusion gradients and optimized navigator echo placement to improve phase correction and artifact reduction, addressing the limitations of conventional phase correction methods. Materials and Methods: The proposed method was compared to the conventional approach, which uses Nav1 for phase correction without dummy diffusion gradients. The new approach incorporates Nav2 for phase correction and dummy diffusion gradients to mitigate eddy current effects. Phantom and in vivo experiments were conducted to evaluate the N/2 ghosting intensity, phase stability, and geometric accuracy. In vivo diffusion- weighted images were acquired at b = 1000 s/mm2 and the effectiveness of the phase correction was qualitatively and quantitatively assessed. Results: Phase evolution analysis revealed that Nav2 more accurately captures diffusion gradient-induced phase perturbations compared to Nav1, leading to improved N/2 ghosting artifact correction. Phantom experiments demonstrated a 41% reduction in N/2 ghosting artifacts using Nav2 compared to Nav1, confirming its superior phase correction capabilities. The in vivo results showed that the proposed method reduced ghosting artifacts and image shifts, leading to an improved alignment of diffusion-weighted images with the reference b = 0 image. Furthermore, the inclusion of dummy diffusion gradients further reduced eddy current-induced artifacts, enhancing image stability and tissue contrast in high-field diffusion-weighted imaging. Conclusion: The proposed method of integrating Nav2 for phase correction and dummy diffusion gradients significantly reduced N/2 ghosting artifacts and geometric distortions in high-field diffusion MRI. These findings suggest that optimizing navigator positioning and incorporating dummy diffusion gradients can enhance the phase stability and improve the reliability of DW-EPI at 7 T. However, as this was a preliminary study with a limited in vivo dataset (n = 2), further validation with larger datasets, different MRI systems, and broader imaging conditions is necessary to fully assess its robustness and clinical applicability.

관련 논문AI추천

Diffusion Encoding Methods in MRI: Perspectives and ChallengesAlan Finkelstein, Congyu Liao, Giovanni Schifitto, Jianhui Zhong, Xiaozhi Cao대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2022 · 제26권 제4호Diffusion MRI With High to Ultrahigh b-Values: How It Will Benefit the Discovery of Brain Microstructure and Pathological ChangesHongjian He, Jianhui Zhong, Min Feng, Paween Wongkornchaovalit대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2022 · 제26권 제4호Generating Motion- and Distortion-Free Local Field Map Using 3D Ultrashort TE MRI: Comparison with T2* Mapping김대홍, 정은희, 한봉수, Bijaya Thapa, Kyle Jeong대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2019 · 제23권 제4호Highly Accelerated SSFP Imaging with Controlled Aliasing in Parallel Imaging and integrated-SSFP (CAIPI-iSSFP)Danny J.J. Wang, Kyunghyun Sung, Peng Hu, Shams Rashid, Steen Moeller, Thomas Martin, Xingfeng Shao, Yi Wang대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2017 · 제21권 제4호Simultaneous Unwrapping Phase and Error Recovery from Inhomogeneity (SUPER) for Quantitative Susceptibility Mapping of the Human Brain백현만, 안창범, 양영중, Jong-Hyun Yoon대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2018 · 제22권 제1호Review of Recent Advancement of Ultra High Field Magnetic Resonance Imaging: from Anatomy to Tractography조장희대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2016 · 제20권 제3호

이 간행물의 다른 논문 (8건)