본문 바로가기
KERD
논문KCI 등재

Reliability Study of Measuring Range of Motion Glenohumeral Joint Internal Rotation With Pressure Biofeedback Stabilization

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류물리치료학

초록

The aims of the current study were to assess reliability of range of motion (ROM) measurement of glenohumeral internal rotation (GIR) with a pressure biofeedback stabilization (PBS) method and to compare the reliability between manual stabilization (MS) and the PBS method. In measurement of pure glenohumeral joint motion, scapular stabilization is necessary. The MS method in GIR ROM measurement was used to restrict scapular motion by pressing the palm of the tester’s hand over the subject’s clavicle, coracoid process, and humeral head. The PBS method was devised to maintain consistent pressure for scapular stabilization during GIR ROM measurement by using a pressure biofeedback unit. GIR ROM was measured by 2 different stabilization methods in 32 subjects with GIR deficit using a smartphone clinometer application. Repeated measurements were performed in two test sessions by two testers to confirm inter- and intra-rater reliability. After tester A performed measurements in test session 1, tester B’s measurements were conducted one hour later on the same day to assess the inter-rater reliability and then tester A performed again measurements in test session 2 for confirming the intra-rater reliability. Intra-class correlation coefficient (ICC) (2,1) was applied to assess the inter-rater reliability and ICC (3,1) was applied to determine the intra-rater reliability of the two methods. In the PBS method, the intra-rater reliability was excellent (ICC=.91) and the inter-rater reliability was good (ICC=.84). The inter-rater and intra-rater reliability of the PBS method was higher than in the MS method. The PBS method could regulate manual scapular stabilization pressure in inter- and intra-rater measuring GIR ROM. Results of the current study recommend that the PBS method can provide reliable measurement data on GIR ROM.

Abstract

The aims of the current study were to assess reliability of range of motion (ROM) measurement of glenohumeral internal rotation (GIR) with a pressure biofeedback stabilization (PBS) method and to compare the reliability between manual stabilization (MS) and the PBS method. In measurement of pure glenohumeral joint motion, scapular stabilization is necessary. The MS method in GIR ROM measurement was used to restrict scapular motion by pressing the palm of the tester’s hand over the subject’s clavicle, coracoid process, and humeral head. The PBS method was devised to maintain consistent pressure for scapular stabilization during GIR ROM measurement by using a pressure biofeedback unit. GIR ROM was measured by 2 different stabilization methods in 32 subjects with GIR deficit using a smartphone clinometer application. Repeated measurements were performed in two test sessions by two testers to confirm inter- and intra-rater reliability. After tester A performed measurements in test session 1, tester B’s measurements were conducted one hour later on the same day to assess the inter-rater reliability and then tester A performed again measurements in test session 2 for confirming the intra-rater reliability. Intra-class correlation coefficient (ICC) (2,1) was applied to assess the inter-rater reliability and ICC (3,1) was applied to determine the intra-rater reliability of the two methods. In the PBS method, the intra-rater reliability was excellent (ICC=.91) and the inter-rater reliability was good (ICC=.84). The inter-rater and intra-rater reliability of the PBS method was higher than in the MS method. The PBS method could regulate manual scapular stabilization pressure in inter- and intra-rater measuring GIR ROM. Results of the current study recommend that the PBS method can provide reliable measurement data on GIR ROM.

참고문헌 (40)

  1. Awan R, "Measuring shoulder internal rotation range of motion: A comparison of 3 techniques", Arch Phys Med Rehabil, 83(9), pp.1229~1234 (2002)
  2. Bigliani LU, "Shoulder motion and laxity in the professional baseball player", Am J Sports Med, 25(5), pp.609~613 (1997)
  3. Boon AJ, "Manual scapular stabilization : Its effect on shoulder rotational range of motion", Arch Phys Med Rehabil, 81(7), pp.978~983 (2000)
  4. Burkhart SS, "Shoulder injuries in overhead athletes. The “dead arm” revisited", Clin Sports Med, 19(1), pp.125~158 (2000)
  5. Burkhart SS, "The disabled throwing shoulder: Spectrum of pathology. Part I: Pathoanatomy and biomechanics", Arthroscopy, 19(4), pp.404~420 (2003)
  6. Burkhart SS, "The disabled throwing shoulder: Spectrum of pathology. Part III: The SICK scapula, scapular dyskinesis, the kinetic chain, and rehabilitation", Arthroscopy, 19(6), pp.641~661 (2003)
  7. Cairns MC, "Pressure biofeedback: A useful tool in the quantification of abdominal muscular dysfunction?", Physiotherapy, 86(3), pp.127~138 (2000)
  8. Chiu TT, "Performance of the craniocervical flexion test in subjects with and without chronic neck pain", J Orthop Sports Phys Ther, 35(9), pp.567~571 (2005)
  9. Comerford M, "Kinetic Control: The management of uncontrolled movement", pp.64~88 (2012), Churchill Livingstone Australia
  10. Crockett HC, "Osseous adaptation and range of motion at the glenohumeral joint in professional baseball pitchers", Am J Sports Med, 30(1), pp.20~26 (2002)
  11. Downar JM, "Clinical measures of shoulder mobility in the professional baseball player", J Athl Train, 40(1), pp.23~29 (2005)
  12. Ellenbecker TS, "Glenohumeral joint total rotation range of motion in elite tennis players and baseball pitchers", Med Sci Sports Exerc, 34(12), pp.2052~2056 (2002)
  13. Ellenbecker TS, "Glenohumeral joint internal and external rotation range of motion in elite junior tennis players", J Orthop Sports Phys Ther, 24(6), pp.336~341 (1996)
  14. Gajdosik RL, "Clinical measurement of range of motion. Review of goniometry emphasizing reliability and validity", Phys Ther, 67(12), pp.1867~1872 (1987)
  15. Gerber C, "Effect of selective capsulorrhaphy on the passive range of motion of the glenohumeral joint", J Bone Joint Surg Am, 85-A(1), pp.48~55 (2003)
  16. Haley SM, "Interpreting change scores of tests and measures used in physical therapy", Phys Ther, 86(5), pp.735~743 (2006)
  17. Hayes K, "Reliability of five methods for assessing shoulder range of motion", Aust J Physiother, 47(4), pp.289~294 (2001)
  18. Howell SM, "Normal and abnormal mechanics of the glenohumeral joint in the horizontal plane", J Bone Joint Surg Am, 70(2), pp.227~232 (1988)
  19. Hudswell S, "The cranio-cervical flexion test using pressure biofeedback: A useful measure of cervical dysfunction in the clinical setting?", Int J Osteopath Med, 8(3), pp.98~105 (2005)
  20. Kelley MJ, "Frozen shoulder: Evidence and a proposed model guiding rehabilitation", J Orthop Sports Phys Ther, 39(2), pp.135~148 (2009)[DOI]
  21. Kolber MJ, "Shoulder joint and muscle characteristics in the recreational weight training population", J Strength Cond Res, 23(1), pp.148~157 (2009)[DOI]
  22. Kolber MJ, "Shoulder joint and muscle characteristics among healthy female recreational weight training participants", J Strength Cond Res, 25(1), pp.231~241 (2011)[DOI]
  23. Laudner KG, "The acute effects of sleeper stretches on shoulder range of motion", J Athl Train, 43(4), pp.359~363 (2008)
  24. Lea RD, "Range-of-motion measurements", J Bone Joint Surg Am, 77(5), pp.784~798 (1995)
  25. Ludewig PM, "The association of scapular kinematics and glenohumeral joint pathologies", J Orthop Sports Phys Ther, 39(2), pp.90~104 (2009)[DOI]
  26. Lunden JB, "Reliability of shoulder internal rotation passive range of motion measurements in the supine versus sidelying position", J Orthop Sports Phys Ther, 40(9), pp.589~594 (2010)
  27. Meister K, "Rotational motion changes in the glenohumeral joint of the adolescent", little league baseball player, 2005, pp.33(5), 693~698
  28. Muir SW, "Evaluating change in clinical status : Reliability and measures of agreement for the assessment of glenohumeral range of motion", N Am J Sports Phys Ther, 5(3), pp.98~110 (2010)
  29. Myers JB, "Influence of humeral torsion on interpretation of posterior shoulder tightness measures in overhead athletes", Clin J Sport Med, 19(5), pp.366~371 (2009)[DOI]
  30. Myers JB, "Reliability, precision, accuracy, and validity of posterior shoulder tightness assessment in overhead athletes", Am J Sports Med, 35(11), pp.1922~1930 (2007)
  31. Park KN, "Effects of the abdominal drawing-in maneuver on muscle activity, pelvic motions, and knee flexion during active prone knee flexion in patients with lumbar extension rotation syndrome", Arch Phys Med Rehabil, 92(9), pp.1477~1483 (2011)[DOI]
  32. Portney L, "Foundations of Clinical Research: Applications to practice", pp.77~96 (2008), Pearson Prentice Hall
  33. Sprague PA, "The relationship between glenohumeral joint total rotational range of motion and the functional movement screen™ shoulder mobility test", Int J Sports Phys Ther, 9(5), pp.657~664 (2014)
  34. Thomas SJ, "A bilateral comparison of posterior capsule thickness and its correlation with glenohumeral range of motion and scapular upward rotation in collegiate baseball players", J Shoulder Elbow Surg, 20(5), pp.708~716 (2011)[DOI]
  35. Ticker JB, "Recognition and treatment of refractory posterior capsular contracture of the shoulder", Arthroscopy, 16(1), pp.27~34 (2000)
  36. Tyler TF, "Quantification of posterior capsule tightness and motion loss in patients with shoulder impingement", Am J Sports Med, 28(5), pp.668~673 (2000)
  37. Weir JP, "Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM", J Strength Cond Res, 19(1), pp.231~240 (2005)
  38. Werner BC, "Validation of an innovative method of shoulder range-of-motion measurement using a smartphone clinometer application", J Shoulder Elbow Surg, 23(11), pp.e275~e282 (2014)
  39. Wilk KE, "Shoulder injuries in the overhead athlete", J Orthop Sports Phys Ther, 39(2), pp.38~54 (2009)[DOI]
  40. Wilk KE, "Glenohumeral internal rotation measurements differ depending on stabilization techniques", Sports Health, 1(2), pp.131~136 (2009)

관련 논문AI추천

어깨관절의 수동적 내회전 관절 가동범위의 측정 방법에 따른 신뢰도와 상완골두의 전방 활주 거리 비교김현숙, 이원휘, 정성대한국전문물리치료학회 · 한국전문물리치료학회지2010 · 제17권 제3호Reliability of Scapular Downward Rotation Measurement in Subjects With Scapular Downward Rotation Syndrome신헌석, 윤태림, 이지현, 정효정, 최우정한국전문물리치료학회 · 한국전문물리치료학회지2014 · 제21권 제3호뇌졸중 환자의 수동적 어깨 관절 가동범위 측정에 관한 스마트폰과 측각기의 측정자내, 측정자간 신뢰도 연구박규남, 박일우, 이충휘, 임원빈한국전문물리치료학회 · 한국전문물리치료학회지2014 · 제21권 제1호Comparison of Glenohumeral Stabilization Exercise and Scapular Stabilization Exercise on Upper Extremity Stability, Alignment, Pain, Muscle Power and Range of Motion in Patients WithNonspecific Shoulder Pain전나영, 천승철한국전문물리치료학회 · 한국전문물리치료학회지2016 · 제23권 제4호노벨 스트레칭과 관절가동술이 어깨 후방 뻣뻣함으로 인한 어깨관절 안쪽돌림 결핍 환자의 관절가동범위와 봉우리-위팔뼈 거리에 미치는 영향김용태, 이상빈대한정형도수물리치료학회 · 대한정형도수물리치료학회지2022 · 제28권 제3호Rotation Control of Shoulder Joint During Shoulder Internal Rotation: A Comparative Study of Individuals With and Without Restricted Range of MotionIl-kyu Ahn, Jun-hee Kim, Min-jeong Chang, Oh-yun Kwon, Ui-jae Hwang한국전문물리치료학회 · 한국전문물리치료학회지2024 · 제31권 제1호

이 간행물의 다른 논문 (9건)