The purpose of the current study was to determine the intra- and inter-rater reliability of muscle thickness (MT) measurement of the psoas major (PM) using ultrasonography (US) conducted at different inward pressures of approximately .5 ㎏, 1.0 ㎏, 1.5 ㎏, and 2.0 ㎏. Twelve healthy male subjects were recruited for the study. The thicknesses of both PMs of each subject were measured by two different examiners in a random manner to assess the intra- and inter-rater reliability. The measurement values were analyzed using the intra-class correlation coefficient (ICC) with a 95% confidence interval (CI). ICC (2,1) was used to determine the inter-rater reliability and ICC (3,1) was used to assess the intra-rater reliability of the MT measurement of the PM. The results indicated higher ICC values for intra-rater reliability compared to inter-rater reliability. In addition, the value for intra-rater reliability with .5 ㎏ inward pressure [ICC=.99 (95%CI=.98∼.99)] was higher compared to 1.0 ㎏, 1.5 ㎏, and 2.0 ㎏. Other inward pressures for intra- and inter-rater reliability in current study were also demonstrated to have excellent values (ICC=.94∼.99). These findings showed that maintaining consistent inward pressure is essential for maintaining reliability of the results when the MT of the PM is measured by different examiners in a clinical setting.

Abstract

The purpose of the current study was to determine the intra- and inter-rater reliability of muscle thickness (MT) measurement of the psoas major (PM) using ultrasonography (US) conducted at different inward pressures of approximately .5 ㎏, 1.0 ㎏, 1.5 ㎏, and 2.0 ㎏. Twelve healthy male subjects were recruited for the study. The thicknesses of both PMs of each subject were measured by two different examiners in a random manner to assess the intra- and inter-rater reliability. The measurement values were analyzed using the intra-class correlation coefficient (ICC) with a 95% confidence interval (CI). ICC (2,1) was used to determine the inter-rater reliability and ICC (3,1) was used to assess the intra-rater reliability of the MT measurement of the PM. The results indicated higher ICC values for intra-rater reliability compared to inter-rater reliability. In addition, the value for intra-rater reliability with .5 ㎏ inward pressure [ICC=.99 (95%CI=.98∼.99)] was higher compared to 1.0 ㎏, 1.5 ㎏, and 2.0 ㎏. Other inward pressures for intra- and inter-rater reliability in current study were also demonstrated to have excellent values (ICC=.94∼.99). These findings showed that maintaining consistent inward pressure is essential for maintaining reliability of the results when the MT of the PM is measured by different examiners in a clinical setting.

참고문헌 (26)

  1. Abe T, "Effects of 20 days bed rest on muscle morphology", J Gravit Physiol, 4(1), pp.S10~S14 (1997)
  2. Abe T, "Prediction equations for body composition of Japanese adults by b-mode ultrasound", Am J Hum Biol, 6(2), pp.161~170 (1994)
  3. Akagi R, "Muscle volume compared to cross-sectional area is more appropriate for evaluating muscle strength in young and elderly individuals", Age Ageing, 38(5), pp.564~569 (2009)
  4. Akbari A, "The effect of motor control exercise versus general exercise on lumbar local stabilizing muscles thickness: Randomized controlled trial of patients with chronic low back pain", J Back Musculoskelet Rehabil, 21(2), pp.105~112 (2008)
  5. Ando K, "Development of probe scan mechanism for echography using pneumatic actuators and its estimation control in contact force on body surface", J Robot Soc Jpn, 28(7), pp.792~801 (2010)
  6. Barker KL, "Changes in the cross-sectional area of multifidus and psoas in patients with unilateral back pain: The relationship to pain and disability", Spine (Phila Pa 1976), 29(22), pp.E515~E519 (2004)
  7. Bohannon RW, "Accuracy of spring and strain gauge hand-held dynamometers", J Orthop Sports Phys Ther, 10(8), pp.323~325 (1989)
  8. Bunce SM, "M-mode ultrasound: A reliable measure of transversus abdominis thickness?", Clin Biomech (Bristol, Avon), 17(4), pp.315~317 (2002)
  9. Cagnie B, "Validity and reliability of ultrasonography for the longus colli in asymptomatic subjects", Man Ther, 14(4), pp.421~426 (2009)
  10. Cooper RG, "Radiographic demonstration of paraspinal muscle wasting in patients with chronic low back pain", Br J Rheumatol, 31(6), pp.389~394 (1992)
  11. Crossley KM, "Analysis of outcome measures for persons with patellofemoral pain: Which are reliable and valid?", Arch Phys Med Rehabil, 85(5), pp.815~822 (2004)
  12. Hayes K, "Reliability of 3 methods for assessing shoulder strength", JShoulder Elbow Surg, 11(1), pp.33~39 (2002)
  13. Ishida H, "Influence of inward pressure of the transducer on lateral abdominal muscle thickness during ultrasound imaging", J Orthop Sports Phys Ther, 42(9), pp.815~818 (2012)
  14. Jhu JL, "Reliability and relationship between 2 measurements of transversus abdominis dimension taken during an abdominal drawing-in maneuver using a novel approach of ultrasound imaging", J Orthop Sports Phys Ther, 40(12), pp.826~832 (2010)
  15. Keagy RD, "Direct electromyography of the psoas major muscle in man", J Bone Joint Surg, 48(7), pp.1377~1382 (1966)
  16. Nachemson A, "Electromyographic studies on the vertebral portion of the psoas muscle; with special reference to its stabilizing function of the lumbar spine", Acta Ortho Scand, 37(2), pp.177~190 (1966)
  17. Nachemson A, "The possible importance of the psoas muscle for stabilization of the lumbar spine", Acta Ortho Scand, 39(1), pp.47~57 (1968)
  18. McGill SM, "Measurement of the trunk musculature from T5 to L5 using MRI scans of 15 young males corrected for muscle fibre orientation", Clin Biomech (Bristol, Avon), 8(4), pp.171~178 (1993)
  19. Sajko S, "Psoas major: A case report and review of its anatomy, biomechanics, and clinical implications", J Can Chiropr Assoc, 53(4), pp.311~318 (2009)
  20. Santaguida PL, "The psoas major muscle: A three-dimensional geometric study", J Biomech, 28(3), pp.339~345 (1995)
  21. Sipilä S, "Ultrasound imaging of the quadriceps muscle in elderly athletes and untrained men", Muscle Nerve, 14(6), pp.527~533 (1991)
  22. Snijder MB, "The prediction of visceral fat by dual-energy x-ray absorptiometry in the elderly: A comparison with computed tomography and anthropometry", Int J Obes Relat Metab Disord, 26(7), pp.984~993 (2002)
  23. Takai Y, "Ultrasound method for estimating the cross-sectional area of the psoas major muscle", Med Sci Sports Exerc, 43(10), pp.2000~2004 (2011)
  24. Tatu L, "Descriptive anatomy of the femoral portion of the iliopsoas muscle. Anatomical basis of anterior snapping of the hip", Surg Radiol Anat, 23(6), pp.371~374 (2001)
  25. Teyhen DS, "Rehabilitative ultrasound imaging of the abdominal muscles", J Orthop Sports Phys Ther, 37(8), pp.450~466 (2007)
  26. Wallwork TL, "Intrarater and interrater reliability of assessment of lumbar multifidus muscle thickness using rehabilitative ultrasound imaging", J Orthop Sports Phys Ther, 37(10), pp.608~612 (2007)

관련 논문AI추천

이 간행물의 다른 논문 (8건)