PURPOSE: The purpose of this study was to examine the inter-rater reliability of a portable ultrasound device for measuring the muscle thickness of the quadriceps and hamstrings in healthy subjects. METHODS: Thirty-six subjects (20 males, 16 females, age 22.2±2.0 years, mass 67.4±11.3 kg, height 171.7±9.6 cm) participated as subjects and two examiners attended. The thickness of the quadriceps was measured in order of rectus femoris (RF), vastus intermedius (VI), vastus lateralis (VL), vastus medialis (VM), and vastus medialis oblique (VMO). The hamstring thickness was measured in order of biceps femoris (BF), semitendinosus (ST), and semimembranosus (SM). Three measurements were taken for each muscle by one examiner. Using image J software, the average thickness was calculated from the measured image. Pearson’s correlation coefficient was used in order to identify inter-rater reliability, and the statistical significance level was set to p<0.05. RESULTS: Pearson correlation coefficient for inter-examiner reliability of ultrasound showed moderate-to-high level for all assessed muscle. In quadriceps, the values were significantly correlated ranged from 0.62 to 0.90 and in hamstrings the value were relatively low with values of 0.57 to 0.68. CONCLUSIONS: The findings of this study indicated that portable ultrasound was a reliable method for measuring the quadriceps and hamstring muscle thickness. Therefore, it could be used as a useful assessment tool in future studies to assess various skeletal muscle thicknesses.

Abstract

PURPOSE: The purpose of this study was to examine the inter-rater reliability of a portable ultrasound device for measuring the muscle thickness of the quadriceps and hamstrings in healthy subjects. METHODS: Thirty-six subjects (20 males, 16 females, age 22.2±2.0 years, mass 67.4±11.3 kg, height 171.7±9.6 cm) participated as subjects and two examiners attended. The thickness of the quadriceps was measured in order of rectus femoris (RF), vastus intermedius (VI), vastus lateralis (VL), vastus medialis (VM), and vastus medialis oblique (VMO). The hamstring thickness was measured in order of biceps femoris (BF), semitendinosus (ST), and semimembranosus (SM). Three measurements were taken for each muscle by one examiner. Using image J software, the average thickness was calculated from the measured image. Pearson’s correlation coefficient was used in order to identify inter-rater reliability, and the statistical significance level was set to p<0.05. RESULTS: Pearson correlation coefficient for inter-examiner reliability of ultrasound showed moderate-to-high level for all assessed muscle. In quadriceps, the values were significantly correlated ranged from 0.62 to 0.90 and in hamstrings the value were relatively low with values of 0.57 to 0.68. CONCLUSIONS: The findings of this study indicated that portable ultrasound was a reliable method for measuring the quadriceps and hamstring muscle thickness. Therefore, it could be used as a useful assessment tool in future studies to assess various skeletal muscle thicknesses.

참고문헌 (21)

  1. Serrão FV, "Effect of tibia rotation on the electromyographical activity of the vastus medialis oblique and vastus lateralis longus muscles during isometric leg press", Phys Ther Sport, 6(1), pp.15~23 (2005)
  2. Williams GN, "Quadriceps weakness, atrophy, and activation failure in predicted noncopers after anterior cruciate ligament injury", Am J Sports Med, 33(3), pp.402~407 (2005)
  3. Arnold JA, "Natural history of anterior cruciate tears", Am J Sports Med, 7(6), pp.305~313 (1979)
  4. Giles LS, "Can ultrasound measurements of muscle thickness be used to measure the size of individual quadriceps muscles in people with patellofemoral pain?", Phys Ther Sport, 16(1), pp.45~52 (2015)
  5. Thomas AC, "Muscle atrophy contributes to quadriceps weakness after anterior cruciate ligament reconstruction", J Sci Med Sport, 19(1), pp.7~11 (2016)
  6. Morse CI, "The validity of estimating quadriceps volume from single MRI cross-sections in young men", Eur J Appl Physiol, 100(3), pp.267~274 (2007)
  7. Hides JA, "Magnetic resonance imaging and ultrasonography of the lumbar multifidus muscle", Comparison of two different modalities. Spine, 20(1), pp.54~58 (1995)
  8. Walton J, "Measurement of the quadriceps femoris muscle using magnetic resonance and ultrasound imaging", Br J Sports Med, 31(1), pp.59~64 (1997)
  9. Chi-Fishman G, "Ultrasound imaging distinguishes between normal and weak muscle", Arch Phys Med Rehabil, 85(6), pp.980~986 (2004)
  10. Henriksson-Larsen K, "Do muscle fibre size and fibre angulation correlate in pennated human muscles?", Eur J Appl Physiol, 64(1), pp.68~72 (1992)
  11. Stetts DM, "A rehabilitative ultrasound imaging investigation of lateral abdominal muscle thickness in healthy aging adults", J Geriatr Phys Ther, 32(2), pp.16~22 (2009)
  12. Sions JM, "Ultrasound imaging : intraexaminer and interexaminer reliability for multifidus muscle thickness assessment in adults aged 60 to 85 years versus younger adults", J Orthop Sports Phys Ther, 44(6), pp.425~434 (2014)
  13. Fox TA, "Dysplasia of the quadriceps mechanism : hypoplasia of the vastus medialis muscle as related to the hypermobile patella syndrome", Surg Clin North Am, 55(1), pp.199~226 (1975)
  14. Pevsner DN, "The patellofemoral joint and its implications in the rehabilitation of the knee", Phys Ther Sport, 59(7), pp.869~874 (1979)
  15. Cagnie B, "Validity and reliability of ultrasonography for the longus colli in asymptomatic subjects", Manual Ther, 14(4), pp.421~426 (2009)
  16. Lin YJ, "Reliability of thickness measurements of the dorsal muscles of the upper cervical spine : an ultrasonographic study", J Orthop Sports Phys Ther, 39(12), pp.850~857 (2009)
  17. Lee JP, "Measurement of segmental cervical multifidus contraction by ultrasonography in asymptomatic adults", Manual Ther, 12(3), pp.286~294 (2007)
  18. Mukaka MM, "A guide to appropriate use of correlation coefficient in medical research", Malawi Med J, 24(3), pp.69~71 (2012)
  19. Kositsky A, "Reliability and Validity of Ultrasonography for Measurement of Hamstring Muscle and Tendon Cross-Sectional Area", Ultrasound Med Biol, 46(1), pp.55~63 (2020)
  20. Palmer TB, "Reliability of panoramic ultrasound imaging in simultaneously examining muscle size and quality of the hamstring muscles in young, healthy males and females", Ultrasound Med Biol, 41(3), pp.675~684 (2015)
  21. 이진아, "건강한 성인의 경장근 두께 측정에 대한 초음파영상법의 신뢰도", 대한물리치료학회지, 23(4), pp.59~66 (2011), 대한물리치료학회

관련 논문AI추천

Intra- and Inter-Rater Reliability of Thickness Measurement of the Psoas Major Muscle Using the Spring Gauge Technique for the Consistent Inward Pressures on Healthy Subjects: An Ultrasonographic Study김용욱, 전인철, 정성대한국전문물리치료학회 · 한국전문물리치료학회지2013 · 제20권 제4호Effects of Vastus Lateralis Muscle Fascicle Length on Isokinetic Muscular Strength and Physical Fitness in Collegiate Athletes이광진, 이호성대한운동학회 · 아시아 운동학 학술지2020 · 제22권 제3호전기근육자극을 적용한 무릎 폄 저항운동 시 넙다리곧은근의 두께 변화에 미치는 즉각적 효과김강훈한국융합학회 · 한국융합학회논문지2021 · 제12권 제6호Inter-Rater Reliability of Abdominal Muscles Thickness Using Ultrasonography for Different Probe Locations and Thicknesses Measurement Techniques박일우, 신헌석, 이충휘, 임원빈, 정도헌, 홍지아한국전문물리치료학회 · 한국전문물리치료학회지2011 · 제18권 제4호Effect of Electrical Muscle Stimulation Training With and Without Superimposed Voluntary Contraction on Rectus Femoris and Vastus Intermedius Thickness and Knee Extension Strength권오윤, Gwak Gyeong-tae, Kim Jun-hee, Lee Do-eun, Park Heon-mi한국전문물리치료학회 · 한국전문물리치료학회지2022 · 제29권 제2호Concurrent Validity and Reliability of Ultrasound-based Muscle Thickness and Inclinometer-based Range of Motion Measurements in Assessing Stretching-induced Changes in Muscle Flexibility in Healthy AdultsChoi Bong-sam, Kim Chang-ho, Park Sookyoung, Yang Jin-hyun한국전문물리치료학회 · 한국전문물리치료학회지2025 · 제32권 제3호