The purpose of this study was to evaluate the effect of passive or active application of primer and coat times of bond on the shear bond strength when a self-etching primer adhesive (Clearfil SE Bond) was applied to enamel surface. Crowns of sixteen human molars were selected. Buccal and lingual enamels of crowns were partially exposed and slabs of 1.2 mm thick were made. They were divided into one of four equal groups (n= 8). Group 1: passive application of Primer and 1 coat of Bond, Group 2: active application of Primer and 1 coat of Bond, Group 3: passive application of Primer and 2 coats of Bond, Group 4: active application of Primer and 2 coats of Bond. Clearfil AP-X was bonded to enamel suface of each group using Tygon tubes. The bonded specimens were subjected to microshear bond strength (uSBS) testing with a crosshead speed of 1 mm/min. The results of this study were as follows; 1. The uSBS of Group 1 was the lowest among groups and the uSBS of Group 4 was the highest. 2. There was not statistically significant interaction between enamel uSBS by application method of Primer and coat time of Bond (p > 0.05). 3. There was not statistically significant difference between enamel uSBS by passive and active application of Primer (p > 0.05). 4. There was statistically significant difference between enamel uSBS by one- and two-coat of Bond (p < 0.05).

Abstract

The purpose of this study was to evaluate the effect of passive or active application of primer and coat times of bond on the shear bond strength when a self-etching primer adhesive (Clearfil SE Bond) was applied to enamel surface. Crowns of sixteen human molars were selected. Buccal and lingual enamels of crowns were partially exposed and slabs of 1.2 mm thick were made. They were divided into one of four equal groups (n= 8). Group 1: passive application of Primer and 1 coat of Bond, Group 2: active application of Primer and 1 coat of Bond, Group 3: passive application of Primer and 2 coats of Bond, Group 4: active application of Primer and 2 coats of Bond. Clearfil AP-X was bonded to enamel suface of each group using Tygon tubes. The bonded specimens were subjected to microshear bond strength (uSBS) testing with a crosshead speed of 1 mm/min. The results of this study were as follows; 1. The uSBS of Group 1 was the lowest among groups and the uSBS of Group 4 was the highest. 2. There was not statistically significant interaction between enamel uSBS by application method of Primer and coat time of Bond (p > 0.05). 3. There was not statistically significant difference between enamel uSBS by passive and active application of Primer (p > 0.05). 4. There was statistically significant difference between enamel uSBS by one- and two-coat of Bond (p < 0.05).

참고문헌 (26)

  1. Oztas N, "Effect of one versus two-layer application of a self-etching adhesives to dentin of primary teeth: a SEM study", J Contemp Dent pract, 15, pp.18~25 (2005)
  2. Semeraro S, "Effect of different bur grinding on the bond strength of self-etching adhesives", Oper Dent, 31, pp.317~323 (2006)
  3. Tani C, "Effect of smear layer thickness on bond strength mediated by three all-in-one self-etching priming adhesives", J Adhes Dent, 4, pp.283~289 (2002)
  4. Gregoire G, "Microscopic evaluation of dentin interface obtained with 10 contemporary self-etching systems: correlation with their pH", Oper Dent, 30, pp.481~491 (2005)
  5. De Munk J, "One-day bonding effectiveness of new self-etch adhesives to burcut enamel and dentin", Oper Dent, 30, pp.39~49 (2005)
  6. Finger WJ, "Effect of application modes on bonding performance of self-etching adhesives", Am J Dent, 18, pp.41~44 (2005)
  7. Miyazaki M, "Influence of dentin primer application methods on dentin bond strength", Oper Dent, 21, pp.167~172 (1996)
  8. Chan KM, "Bonding of mild self-etching primers", adhesives to dentin with thick smear layers, 2003, pp.16, 340~346
  9. Pashley EL, "Effect of one versus two applications of an unfilled, all-in-one adhesive on dentin bonding", J Dent, 30, pp.83~90 (2002)
  10. Ito S, "Effects of multiple coatings of two all-in-one adhesives on dentin bonding", J Adhes Dent, 7, pp.133~141 (2005)
  11. Tay FR, "Aggressiveness of self-etch adhesives on unground enamel", Oper Dent, 29, pp.309~316 (2004)
  12. Pashley DH, "Aggressiveness of contemporary self-etch adhesives. part II: Etching effects on unground enamel", Dent Mater, 17, pp.430~444 (2004)
  13. Tay FR, "Effect of smear layers on the bonding of a self-etching primer to dentin", J Adhes Dent, 2, pp.99~116 (2000)
  14. Torii Y, "Effect of phosphoric acid etching to self-etching primer application on adhesion of resin composite to enamel and dentin", Am J Dent, 15, pp.305~308 (2002)
  15. Jacobsen T, "Effect of primer solvent, primer agitation, and dentin dryness on shear bond strength to dentin", Am J Dent, 11, pp.225~228 (1998)
  16. Castro PS, "Effect of application modes of self-etching primers on dentin bonding strength", J Dent Res, 81(1146) (2000)
  17. Watanabe IG, "Expanding horizons of biomaterials and technology in : Effects of application technique (agitation vs no-agitation) of a self-etching bonding material on shear bond strength", Transactions of fourth international congress on dental materials, 통권 : 16, pp.165~ (2002), Academy of Dental Materials
  18. Miyazaki M, "Effect of self-etching primer application method on the enamel bond strength", Am J Dent, 15, pp.412~416 (2002)
  19. Swift Jr EJ, "Shear bond stregths of one-bottle dentin adhesives using multiple applications", Oper Dent, 22, pp.194~199 (1997)
  20. Bonilla ED, "Effect of application technique and dentin bonding agent interaction on shear bond strength", Oper Dent, 28, pp.568~573 (2003)
  21. Sano H, "Relationship between surface area for adhesion and tensile bond strength- evaluation of a micro-tensile bond test", Dent Mat, 10, pp.236~240 (1994)
  22. Shimada Y, "Shear bond strength of current adhesive systems to enamel, dentin and dentin-enamel junction region", Oper Dent, 28, pp.585~590 (2003)
  23. Barkmeier WW, "Bond strengths and SEM evaluation of Clearfil Liner Bond 2", Am J Dent, 8, pp.289~293 (1995)
  24. Inoue H, "Microtensile bond strength of two single-step adhesive systems to bur-prepared dentin", J Adhes Dent, 3, pp.129~136 (2001)
  25. Choi KK, "The effects of adhesive thickness on polymerization contraction stress of composite", J Dent, 79, pp.812~817 (2000)
  26. Hilton TJ, "The effect of air thinning on dentin adhesive bond strength", Oper Dent, 20, pp.133~137 (1995)

관련 논문AI추천