와동의 형태가 상아질과 복합레진 사이의 미세인장결합강도에 미치는 영향
THE INFLUENCE OF CAVITY CONFIGURATION ON THE MICROTENSILE BOND STRENGTH BETWEEN COMPOSITE RESIN AND DENTIN
0
조회
0
다운로드
3
인용
0
참고문헌
키워드
초록
This study was conducted to evaluate the influence of the C-factor on the bond strength of a 6th generation self-etching system by measuring the microtensile bond strength of four types of restorations classified by different C-factors with an identical depth of dentin. Eighty human molars were divided into four experimental groups, each of which had a C-factor of 0.25, 2, 3 or 4. Each group was then further divided into four subgroups based on the adhesive and composite resin used. The adhesives used for this study were AQ Bond Plus (Sun Medical, Japan) and XenoⅢ (DENTSPLY, Germany). And composite resins used were Fantasista (Sun Medical, Japan) and Ceram-X mono (DENTSPLY, Germany). The results were then analyzed using one-way ANOVA, a Tukey’s test, and a Pearson’s correlation test and were as follows. 1. There was no significant difference among C-factor groups with the exception of groups of XenoⅢ and Ceram-X mono (p < 0.05). 2. There was no significant difference between any of the adhesives and composite resins in groups with C-factor 0.25, 2 and 4. 3. There was no correlation between the change in C-factor and microtensile bond strength in the Fantasista groups. It was concluded that the C-factor of cavities does not have a significant effect on the microtensile bond strength of the restorations when cavities of the same depth of dentin are restored using composite resin in conjunction with the 6th generation self-etching system.
Abstract
This study was conducted to evaluate the influence of the C-factor on the bond strength of a 6th generation self-etching system by measuring the microtensile bond strength of four types of restorations classified by different C-factors with an identical depth of dentin. Eighty human molars were divided into four experimental groups, each of which had a C-factor of 0.25, 2, 3 or 4. Each group was then further divided into four subgroups based on the adhesive and composite resin used. The adhesives used for this study were AQ Bond Plus (Sun Medical, Japan) and XenoⅢ (DENTSPLY, Germany). And composite resins used were Fantasista (Sun Medical, Japan) and Ceram-X mono (DENTSPLY, Germany). The results were then analyzed using one-way ANOVA, a Tukey’s test, and a Pearson’s correlation test and were as follows. 1. There was no significant difference among C-factor groups with the exception of groups of XenoⅢ and Ceram-X mono (p < 0.05). 2. There was no significant difference between any of the adhesives and composite resins in groups with C-factor 0.25, 2 and 4. 3. There was no correlation between the change in C-factor and microtensile bond strength in the Fantasista groups. It was concluded that the C-factor of cavities does not have a significant effect on the microtensile bond strength of the restorations when cavities of the same depth of dentin are restored using composite resin in conjunction with the 6th generation self-etching system.
참고문헌 (26)
- Davidson CL, "Relaxation of polymerization contraction stresses by flow in dental composites", J Dent Res, 63, pp.146~148 (1984)
- Davidson CL, "Resisting the curing contraction with adhesive composites", J Prosthet Dent, 55, pp.446~447 (1986)
- Feilzer AJ, "Setting stress in composite resin in relation to configuration of the restoration", J Dent Res, 66, pp.1636~1639 (1987)
- Feilzer AJ, "Setting stresses in composites for two different curing modes", Dent Mater, 9, pp.2~5 (1993)
- Alster D, "Polymerization contraction stress in thin resin composite layers as a function of layer thickness", Dent Mater, 13, pp.146~150 (1997)
- Versluis A, "Do dental composites always shrink toward the light?", J Dent Res, 77, pp.1435~1445 (1998)
- He Z, "The effect of cavity size and incremental technique on micro-tensile bond strength of resin composite in Class Ⅰcavities", Dent Mater, 23, pp.533~538 (2007)
- Uno S, "The influence of configuration factors on cavity adaptation in compomer restoration", Dent Mater, 18, pp.19~31 (1999)
- Shirai K, "Effect of cavity configuration and agind on the bonding effectiveness of six adhesives to dentin", Dent Mater, 21, pp.110~124 (2005)
- Wattanawongpitak N, "The effect of bonding system and composite type on adaptation of different C-factor restorations", Dent Mater, 25, pp.45~50 (2006)
- Sano H, "Relationship between surface area for adhesion and tensile bond strength - Evaluation of a micro-tensile bond test", Dent Mater, 10, pp.236~240 (1994)
- Nakajima M, "Comparative microtensile bond strength and SEM analysis of bonding to wet and dry dentin", Am J Dent, 13, pp.324~328 (2000)
- Frankenberger R, "“Nobottle” vs “multi-bottle”dentin adhesives: a microtensile bond strength and morphological study", Dent Mater, 17, pp.373~380 (2001)
- Yoshikawa T, "Effects of dentin depth and cavity configuration on bond strength", J Dent Res, 78, pp.898~905 (1999)
- Mallmann A, "Microtensile dentin bond strength of self-etching and single-bottle adhesive systems in different cavity configurations", J Adhes Dent, 5, pp.121~127 (2003)
- 김보경, "와동의 형태가 상아질과 복합레진 사이의 결합력에 미치는 영향", 석사, pp.2007
- Suzuki T, "Dentin adhesives: site of dentin vs. bonding of composite resins", Dent Mater, 4, pp.379~383 (1988)
- Burrow MF, "The influence of age and depth of dentin on bonding", Dent Mater, 10, pp.241~246 (1994)
- Inoue T, "Anisotropy of tensile strengths of bovine dentin regarding dentinal tubule orientation and location", Dent Mater, 21, pp.32~43 (2002)
- Perinka L, "Dentin thickness, hardness and Ca-concentration vs. bond strength of dentin adhesives", Dent Mater, 8, pp.229~233 (1992)
- Phrukkanon S, "The effect of dentine location and tubule orientation on the bond strengths between resin and dentine", J Dent, 27, pp.265~274 (1999)
- Prati C, "Dentin wetness, permeability and thickness and bond strength of adhesive systems", Am J Dent, 5, pp.33~38 (1992)
- Tagami J, "Correlation among dentin depth, permeability and bond strength of adhesive resins", Dent Mater, 6, pp.45~50 (1990)
- Choi KK, "Effects of cavity configuration on composite restoration", Oper Dent, 29, pp.462~469 (2004)
- Ruttermann S, "Polymerization shrinkage and hygroscopic expansion of contemporary posterior resin-based filling materials - a comparative study", J Dent, 35, pp.806~813 (2007)
- Kishikawa R, "Effect of cavity form on adhesion to cavity floor", Am J Dent, 18, pp.311~314 (2005)
