A study on the compatibility between one-bottle dentin adhesives and composite resins using micro-shear bond strength
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Objectives: This study was performed to determine whether the combined use of onebottle self-etch adhesives and composite resins from same manufacturers have better bond strengths than combinations of adhesive and resins from different manufacturers. Materials and Methods: 25 experimental micro-shear bond test groups were made from combinations of five dentin adhesives and five composite resins with extracted human molars stored in saline for 24 hr. Testing was performed using the wire-loop method and a universal testing machine. Bond strength data was statistically analyzed using two way analysis of variance (ANOVA) and Tukey’s post hoc test. Results: Two way ANOVA revealed significant differences for the factors of dentin adhesives and composite resins, and significant interaction effect (p < 0.001). All combinations with Xeno V (Dentsply De Trey) and Clearfil S3 Bond (Kuraray Dental) adhesives showed no significant differences in micro-shear bond strength, but other adhesives showed significant differences depending on the composite resin (p < 0.05). Contrary to the other adhesives, Xeno V and BondForce (Tokuyama Dental) had higher bond strengths with the same manufacturer’s composite resin than other manufacturer’s composite resin. Conclusions: Not all combinations of adhesive and composite resin by same manufacturers failed to show significantly higher bond strengths than mixed manufacturer combinations.
Abstract
Objectives: This study was performed to determine whether the combined use of onebottle self-etch adhesives and composite resins from same manufacturers have better bond strengths than combinations of adhesive and resins from different manufacturers. Materials and Methods: 25 experimental micro-shear bond test groups were made from combinations of five dentin adhesives and five composite resins with extracted human molars stored in saline for 24 hr. Testing was performed using the wire-loop method and a universal testing machine. Bond strength data was statistically analyzed using two way analysis of variance (ANOVA) and Tukey’s post hoc test. Results: Two way ANOVA revealed significant differences for the factors of dentin adhesives and composite resins, and significant interaction effect (p < 0.001). All combinations with Xeno V (Dentsply De Trey) and Clearfil S3 Bond (Kuraray Dental) adhesives showed no significant differences in micro-shear bond strength, but other adhesives showed significant differences depending on the composite resin (p < 0.05). Contrary to the other adhesives, Xeno V and BondForce (Tokuyama Dental) had higher bond strengths with the same manufacturer’s composite resin than other manufacturer’s composite resin. Conclusions: Not all combinations of adhesive and composite resin by same manufacturers failed to show significantly higher bond strengths than mixed manufacturer combinations.
참고문헌 (23)
- Asmussen E, "Adhesion of restorative resins to dentin : chemical and physicochemical aspects", Oper Dent, (Suppl 5), pp.68~74 (1992)
- Van Landuyt KL, "Monomer-solvent phase separation in one-step self-etch adhesives", J Dent Res, 84, pp.183~188 (2005)
- Kugel G, "The science of bonding: from first to sixth generation", J Am Dent Assoc, 131(Suppl), pp.20S~25S (2000)
- Perdigao J, "New concepts in dental adhesion", Northwest Dent, 79, pp.29~33 (2000)
- Freedman G, "Seventh-generation adhesive systems", Dent Today, 21, pp.106~111 (2002)
- Yoshida Y, "Comparative study on adhesive performance of functional monomers", J Dent Res, 83, pp.454~458 (2004)
- Van Landuyt KL, "Influence of the chemical structure of functional monomers on their adhesive performance", J Dent Res, 87, pp.757~761 (2008)
- Perdigão J, "In vitro interfacial relationship between human dentin and one-bottle dental adhesives", Dent Mater, 13, pp.218~227 (1997)
- Van Meerbeek B, "Fundamentals of operative dentistry", pp.193~260 (2006), Quintessence Publishing co, Inc
- Leirskar J, "In vitro shear bond strength of two resin composites to dentin with five different dentin adhesives", Quintessence Int, 29, pp.787~792 (1998)
- Roh BD, "Micro-shear bond strength of five resin-based composites to dentin with five different dentin adhesives", Am J Dent, 18, pp.333~337 (2005)
- Pashley DH, "Adhesion testing of dentin bonding agents: a review", Dent Mater, 11, pp.117~125 (1995)
- Tanumiharja M, "Microtensile bond strengths of seven dentin adhesive systems", Dent Mater, 16, pp.180~187 (2000)
- Yoshida Y, "Comparative study on adhesive performance of functional monomers", J Dent Res, 83, pp.454~458 (2004)
- Van Meerbeek B, "Technique-sensitivity of contemporary adhesives", Dent Mater J, 24, pp.1~13 (2005)
- Inoue S, "Microtensile bond strength of eleven contemporary adhesives to dentin", J Adhes Dent, 3, pp.237~245 (2001)
- Perdigão J, "New developments in dental adhesion", Dent Clin North Am, 51, pp.333~357 (2007)
- Koshiro K, "New concept of resin-dentin interfacial adhesion: the nanointeraction zone", J Biomed Mater Res B Appl Biomater, 77, pp.401~408 (2006)
- Van Meerbeek B, "Buonocore memorial lecture. Adhesion to enamel and dentin: current status and future challenges", Oper Dent, 28, pp.215~235 (2003)
- De Munck J, "A critical review of the durability of adhesion to tooth tissue:methods and results", J Dent Res, 84, pp.118~132 (2005)
- Poptani B, "Microtensile dentin bond strength of fifth with five seventhgeneration dentin bonding agents after thermocycling:An in vitro study", Contemp Clin Dent, 3, pp.S167~S171 (2012)
- Hegde MN, "An evalution of compressive strength of newer nanocomposite: an in vitro study", J Conserv Dent, 14, pp.36~39 (2011)
- Willems G, "Composite resins in the 21st century", Quintessence Int, 24, pp.641~658 (1993)
