Plugger temperature of cordless heat carriers according to the time elapsed

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Objective The purpose of this study was to measure the temperature of the plugger tip of 3 cordless heat carriers set at 200°C. Materials and Methods Pluggers of the same taper (0.06, 0.08, 0.10) and similar tip sizes (sizes of 50 and 55) from 3 cordless heat carriers, namely SuperEndo-α2 (B & L Biotech), Friendo (DXM), and Dia-Pen (Diadent), were used and an electric heat carrier, System B (SybronEndo), was used as the control. The plugger tips were covered with customized copper sleeves, heated for 10 seconds, and the temperature was recorded with a computerized measurement system attached to a K-type thermometer at room temperature (n = 10). The data were analyzed with 2-way analysis of variance at a 5% level of significance. Results The peak temperature of the plugger tips was significantly affected by the plugger taper and by the heat carrier brand (p < 0.05). The peak temperature of the plugger tips was between 177°C and 325°C. The temperature peaked at 207°C–231°C for the 0.06 taper pluggers, 195°C–313°C for the 0.08 taper pluggers, and 177°C–325°C for the 0.10 taper pluggers. Only 5 of the 12 plugger tips showed a temperature of 200°C ± 10°C. The time required to reach the highest temperature or 200°C ± 10°C was at least 4 seconds. Conclusion When using cordless heat carriers, clinicians should pay attention to the temperature setting and to the activation time needed to reach the intended temperature of the pluggers.

Abstract

Objective The purpose of this study was to measure the temperature of the plugger tip of 3 cordless heat carriers set at 200°C. Materials and Methods Pluggers of the same taper (0.06, 0.08, 0.10) and similar tip sizes (sizes of 50 and 55) from 3 cordless heat carriers, namely SuperEndo-α2 (B & L Biotech), Friendo (DXM), and Dia-Pen (Diadent), were used and an electric heat carrier, System B (SybronEndo), was used as the control. The plugger tips were covered with customized copper sleeves, heated for 10 seconds, and the temperature was recorded with a computerized measurement system attached to a K-type thermometer at room temperature (n = 10). The data were analyzed with 2-way analysis of variance at a 5% level of significance. Results The peak temperature of the plugger tips was significantly affected by the plugger taper and by the heat carrier brand (p < 0.05). The peak temperature of the plugger tips was between 177°C and 325°C. The temperature peaked at 207°C–231°C for the 0.06 taper pluggers, 195°C–313°C for the 0.08 taper pluggers, and 177°C–325°C for the 0.10 taper pluggers. Only 5 of the 12 plugger tips showed a temperature of 200°C ± 10°C. The time required to reach the highest temperature or 200°C ± 10°C was at least 4 seconds. Conclusion When using cordless heat carriers, clinicians should pay attention to the temperature setting and to the activation time needed to reach the intended temperature of the pluggers.

참고문헌 (17)

  1. Venturi M, "Temperature change within gutta-percha induced by the System-B Heat Source", Int Endod J, 35, pp.740~746 (2002)[DOI]
  2. Buchanan LS, "The continuous wave of obturation technique: 'centered' condensation of warm gutta percha in 12 seconds", Dent Today, 15, pp.60~ (1996)
  3. Villegas JC, "Intracanal temperature rise evaluation during the usage of the System B: replication of intracanal anatomy", Int Endod J, 38, pp.218~222 (2005)[DOI]
  4. Schilder H, "The thermomechanical properties of gutta-percha. Part V. Volume changes in bulk gutta-percha as a function of temperature and its relationship to molecular phase transformation", Oral Surg Oral Med Oral Pathol, 59, pp.285~296 (1985)[DOI]
  5. Maniglia-Ferreira C, "Brazilian gutta-percha points. Part II: thermal properties", Braz Oral Res, 21, pp.29~34 (2007)
  6. Combe EC, "Alpha-and beta-forms of gutta-percha in products for root canal flling", Int Endod J, 34, pp.447~451 (2001)[DOI]
  7. Blum JY, "Warm vertical compaction sequences in relation to gutta-percha temperature", J Endod, 23, pp.307~311 (1997)[DOI]
  8. Silver GK, "Comparison of two vertical condensation obturation techniques: Touch 'n Heat modifed and System B", Int Endod J, 32, pp.287~295 (1999)[DOI]
  9. 최성아, "적외선열화상장치를 이용한 Buchanan plugger 표면의 온도상승 분석", Restorative Dentistry and Endodontics, 27(4), pp.370~381 (2002), 대한치과보존학회
  10. Viapiana R, "Investigation of chemical changes in sealers during application of the warm vertical compaction technique", Int Endod J, 48, pp.16~27 (2015)[DOI]
  11. Sant'Anna-Junior A, "Temperature changes in gutta-percha and Resilon cones induced by a thermomechanical compaction technique", J Endod, 35, pp.879~882 (2009)[DOI]
  12. Lipski M, "Root surface temperature rises during root canal obturation, in vitro, by the continuous wave of condensation technique using System B HeatSource", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 99, pp.505~510 (2005)[DOI]
  13. Lipski M, "Root surface temperature rises in vitro during root canal obturation using hybrid and microseal techniques", J Endod, 31, pp.297~300 (2005)[DOI]
  14. Lipski M, "In vitro infrared thermographic assessment of root surface temperature rises during thermafl retreatment using system B", J Endod, 29, pp.413~415 (2003)[DOI]
  15. Mc Cullagh JJ, "A comparison of thermocouple and infrared thermographic analysis of temperature rise on the root surface during the continuous wave of condensation technique", Int Endod J, 33, pp.326~332 (2000)[DOI]
  16. Chang HS, "Thermal analysis of bulk flled composite resin polymerization using various light curing modes according to the curing depth and approximation to the cavity wall", J Appl Oral Sci, 21, pp.293~299 (2013)[DOI]
  17. Jurcak JJ, "In vitro intracanal temperatures produced during warm lateral condensation of Gutta-percha", J Endod, 18, pp.1~3 (1992)[DOI]

관련 논문AI추천

Continuous Wave of Condensation Technique으로 근관충전시 치근면 온도상승 분석김선호, 김영주, 오원만, 정영진, 정우남, 최보영, 황윤찬, 황인남대한치과보존학회 · Restorative Dentistry and Endodontics2003 · 제28권 제4호Influence of plugger penetration depth on the apical extrusion of root canal sealer in continuous wave of condensation technique김광근, 김기옥, 김성교, 김영경, 소호영, 이영미대한치과보존학회 · Restorative Dentistry and Endodontics2004 · 제29권 제5호Effect of cooling water temperature on the temperature changes in pulp chamber and at handpiece head during high-speed tooth preparationRa'fat I. Farah대한치과보존학회 · Restorative Dentistry and Endodontics2019 · 제44권 제1호Root canal volume change and transportation by Vortex Blue, ProTaper Next, and ProTaper Universal in curved root canals문영미, 서민석, Hyun-Jin Park대한치과보존학회 · Restorative Dentistry and Endodontics2018 · 제43권 제1호Tip and taper compatibility of accessory gutta-percha points with rotary and reciprocating instrumentsArcaro Sabrina, Bernardi Anarela Vassen, Bortoluzzi Eduardo Antunes, Ceretta Renan Antônio, de Almeida Josiane, Garcia Lucas da Fonseca Roberti, Kopper Patrícia Maria Poli, Streck Júlia Niero Zanatta대한치과보존학회 · Restorative Dentistry and Endodontics2023 · 제48권 제3호Phase transformation temperatures influence the reduction ratio of fatigue resistance of nickel-titanium reciprocating files at body temperature: an in vitro experimental study곽상원, 김현철, Diemer Franck, Georgelin-Gurgel Marie, Lê Sylvie, Naaman Alfred, Nehme Walid, Pedèches Lola대한치과보존학회 · Restorative Dentistry and Endodontics2025 · 제50권 제4호

이 간행물의 다른 논문 (12건)