Root canal volume change and transportation by Vortex Blue, ProTaper Next, and ProTaper Universal in curved root canals
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Objectives The aim of this study was to compare root canal volume change and canal transportation by Vortex Blue (VB; Dentsply Tulsa Dental Specialties), ProTaper Next (PTN; Dentsply Maillefer), and ProTaper Universal (PTU; Dentsply Maillefer) nickel-titanium rotary files in curved root canals. Materials and Methods Thirty canals with 20°–45° of curvature from extracted human molars were used. Root canal instrumentation was performed with VB, PTN, and PTU files up to #30.06, X3, and F3, respectively. Changes in root canal volume before and after the instrumentation, and the amount and direction of canal transportation at 1, 3, and 5 mm from the root apex were measured by using micro-computed tomography. Data of canal volume change were statistically analyzed using one-way analysis of variance and Tukey test, while data of amount and direction of transportation were analyzed using Kruskal-Wallis and Mann-Whitney U test. Results There were no significant differences among 3 groups in terms of canal volume change (p > 0.05). For the amount of transportation, PTN showed significantly less transportation than PTU at 3 mm level (p = 0.005). VB files showed no significant difference in canal transportation at all 3 levels with either PTN or PTU files. Also, VB files showed unique inward transportation tendency in the apical area. Conclusions Other than PTN produced less amount of transportation than PTU at 3 mm level, all 3 file systems showed similar level of canal volume change and transportation, and VB file system could prepare the curved canals without significant shaping errors.
Abstract
Objectives The aim of this study was to compare root canal volume change and canal transportation by Vortex Blue (VB; Dentsply Tulsa Dental Specialties), ProTaper Next (PTN; Dentsply Maillefer), and ProTaper Universal (PTU; Dentsply Maillefer) nickel-titanium rotary files in curved root canals. Materials and Methods Thirty canals with 20°–45° of curvature from extracted human molars were used. Root canal instrumentation was performed with VB, PTN, and PTU files up to #30.06, X3, and F3, respectively. Changes in root canal volume before and after the instrumentation, and the amount and direction of canal transportation at 1, 3, and 5 mm from the root apex were measured by using micro-computed tomography. Data of canal volume change were statistically analyzed using one-way analysis of variance and Tukey test, while data of amount and direction of transportation were analyzed using Kruskal-Wallis and Mann-Whitney U test. Results There were no significant differences among 3 groups in terms of canal volume change (p > 0.05). For the amount of transportation, PTN showed significantly less transportation than PTU at 3 mm level (p = 0.005). VB files showed no significant difference in canal transportation at all 3 levels with either PTN or PTU files. Also, VB files showed unique inward transportation tendency in the apical area. Conclusions Other than PTN produced less amount of transportation than PTU at 3 mm level, all 3 file systems showed similar level of canal volume change and transportation, and VB file system could prepare the curved canals without significant shaping errors.
참고문헌 (39)
- Schafer E, "Impact of nickel-titanium instrumentation of the root canal on clinical outcomes: a focused review", Odontology, 100, pp.130~136 (2012)[DOI]
- Elnaghy AM, "Cyclic fatigue resistance of ProTaper Next nickel-titanium rotary fles", Int Endod J, 47, pp.1034~1039 (2014)[DOI]
- Kim HC, "Stress generation during self-adjusting fle movement: minimally invasive instrumentation", J Endod, 39, pp.1572~1575 (2013)[DOI]
- Pirani C, "HyFlex EDM: superfcial features, metallurgical analysis and fatigue resistance of innovative electro discharge machined NiTi rotary instruments", Int Endod J, 49, pp.483~493 (2016)[DOI]
- Bonessio N, "Validated fnite element analyses of WaveOne Endodontic Instruments: a comparison between M-Wire and NiTi alloys", Int Endod J, 48, pp.441~450 (2015)[DOI]
- McRay B, "A micro-computed tomography-based comparison of the canal transportation and centering ability of ProTaper Universal rotary and WaveOne reciprocating fles", Quintessence Int, 45, pp.101~108 (2014)
- Nguyen HH, "Evaluation of the resistance to cyclic fatigue among ProTaper Next, ProTaper Universal, and Vortex Blue rotary instruments", J Endod, 40, pp.1190~1193 (2014)[DOI]
- Plotino G, "Blue treatment enhances cyclic fatigue resistance of vortex nickel-titanium rotary fles", J Endod, 40, pp.1451~1453 (2014)[DOI]
- Shen Y, "ProFile Vortex and Vortex Blue nickel-titanium rotary instruments afer clinical use", J Endod, 41, pp.937~942 (2015)[DOI]
- Capar ID, "Comparative study of diferent novel nickel-titanium rotary systems for root canal preparation in severely curved root canals", J Endod, 40, pp.852~856 (2014)[DOI]
- Uygun AD, "Variations in cyclic fatigue resistance among ProTaper Gold, ProTaper Next and ProTaper Universal instruments at diferent levels", Int Endod J, 49, pp.494~499 (2016)[DOI]
- Gagliardi J, "Evaluation of the shaping characteristics of ProTaper Gold, ProTaper NEXT, and ProTaper Universal in curved canals", J Endod, 41, pp.1718~1724 (2015)[DOI]
- Gao Y, "Evaluation of the impact of raw materials on the fatigue and mechanical properties of ProFile Vortex rotary instruments", J Endod, 38, pp.398~401 (2012)[DOI]
- Schneider SW, "A comparison of canal preparations in straight and curved root canals", Oral Surg Oral Med Oral Pathol, 32, pp.271~275 (1971)[DOI]
- Gambill JM, "Comparison of nickel-titanium and stainless steel hand-fle instrumentation using computed tomography", J Endod, 22, pp.369~375 (1996)[DOI]
- You SY, "Shaping ability of reciprocating motion in curved root canals: a comparative study with micro-computed tomography", J Endod, 37, pp.1296~1300 (2011)[DOI]
- Celikten B, "Micro-CT assessment of the sealing ability of three root canal flling techniques", J Oral Sci, 57, pp.361~366 (2015)[DOI]
- Marceliano-Alves MF, "Shaping ability of single-fle reciprocating and heat-treated multifle rotary systems: a micro-CT study", Int Endod J, 48, pp.1129~1136 (2015)[DOI]
- Huang CC, "Analysis of the width of vertical root fracture in endodontically treated teeth by 2 micro-computed tomography systems", J Endod, 40, pp.698~702 (2014)[DOI]
- Siqueira JF Jr, "Ability of chemomechanical preparation with either rotary instruments or self-adjusting fle to disinfect oval-shaped root canals", J Endod, 36, pp.1860~1865 (2010)[DOI]
- Tang W, "Identifying and reducing risks for potential fractures in endodontically treated teeth", J Endod, 36, pp.609~617 (2010)[DOI]
- Pasqualini D, "Micro-Computed tomography evaluation of ProTaper Next and BioRace shaping outcomes in maxillary frst molar curved canals", J Endod, 41, pp.1706~1710 (2015)[DOI]
- Zhao D, "Root canal preparation of mandibular molars with 3 nickel- titanium rotary instruments: a micro-computed tomographic study", J Endod, 40, pp.1860~1864 (2014)[DOI]
- Cruz A, "Debris remaining in the apical third of root canals afer chemomechanical preparation by using sodium hypochlorite and glyde: an in?vivo study", J Endod, 40, pp.1419~1423 (2014)[DOI]
- Burklein S, "Shaping ability of ProTaper NEXT and BT-RaCe nickel-titanium instruments in severely curved root canals", Int Endod J, 48, pp.774~781 (2015)[DOI]
- Celikten B, "Comparative evaluation of shaping ability of two nickel-titanium rotary systems using cone beam computed tomography", BMC Oral Health, 15, pp.32~ (2015)[DOI]
- Kandaswamy D, "Canal-centering ability: an endodontic challenge", J Conserv Dent, 12, pp.3~9 (2009)[DOI]
- Alapati SB, "Metallurgical characterization of a new nickel-titanium wire for rotary endodontic instruments", J Endod, 35, pp.1589~1593 (2009)[DOI]
- Shen Y, "Current challenges and concepts of the thermomechanical treatment of nickel-titanium instruments", J Endod, 39, pp.163~172 (2013)[DOI]
- Duke F, "Cyclic fatigue of ProFile Vortex and Vortex Blue nickel-titanium fles in single and double curvatures", J Endod, 41, pp.1686~1690 (2015)[DOI]
- Dummer PM, "A method for the construction of simulated root canals in clear resin blocks", Int Endod J, 24, pp.63~66 (1991)[DOI]
- 임영준, "Comparison of the centering ability of Wave·One and Reciproc nickel-titanium instruments in simulated curved canals", Restorative Dentistry and Endodontics, 38(1), pp.21~25 (2013), 대한치과보존학회[DOI]
- 유영실, "A comparison of the shaping ability of reciprocating NiTi instruments in simulated curved canals", Restorative Dentistry and Endodontics, 37(4), pp.220~227 (2012), 대한치과보존학회[DOI]
- Peters OA, "ProTaper rotary root canal preparation: efects of canal anatomy on fnal shape analysed by micro CT", Int Endod J, 36, pp.86~92 (2003)[DOI]
- Ha JH, "Geometric optimization for development of glide path preparation nickel-titanium rotary instrument", J Endod, 41, pp.916~919 (2015)[DOI]
- Berutti E, "Root canal anatomy preservation of WaveOne reciprocating fles with or without glide path", J Endod, 38, pp.101~104 (2012)
- Pagliosa A, "Computed tomography evaluation of rotary systems on the root canal transportation and centering ability", Braz Oral Res, 29, pp.1~7 (2015)
- Weine FS, "The efect of preparation procedures on original canal shape and on apical foramen shape", J Endod, 1, pp.255~262 (1975)[DOI]
- Wu MK, "Leakage along apical root fllings in curved root canals. Part I: efects of apical transportation on seal of root fllings", J Endod, 26, pp.210~216 (2000)[DOI]
