Objectives: This study was conducted to evaluate and compare the tip and taper compatibility of accessory gutta-percha points (AGPs) with various rotary and reciprocating instruments. Materials and Methods: Using a profile analyzer, tip and taper measurements were taken of 10 AGPs of each of the 14 models available from Odous de Deus and the 4 models available from Dentsply-Maillefer. Diameter measurements were taken at 1-mm intervals, from 3 mm from the tip (D3) to 16 mm. Results: Based on the mean values obtained, 3-dimensional (3D) models of the AGPs were drawn in Autodesk Fusion 360 and superimposed on 3D models of each instrument selected (Mtwo, Reciproc, RaCe, K3, and ProDesign Logic) to determine the compatibility between the instrument and the AGP. Data corresponding to the tips and tapers of the various AGPs, as well as the tip and taper differences between the AGPs and the instruments, were analyzed using descriptive statistics. The tapers of the AGPs were subject to the American National Standards Institute/American Dental Association No. 57 standard. The Odous de Deus extra-long medium and extra-long extra-medium AGPs were shown to be compatible with Mtwo, K3, and ProDesign Logic instruments with taper 0.06 and tip sizes 25 and 30, while the Dentsply fine and fine medium cones were compatible with Mtwo, RaCe, and K3 instruments with conicity of 0.04 and tip sizes 35 and 40. Conclusions: Both the Odous de Deus and Dentsply commercial brands included 2 AGP models with tip (D3) and taper compatibility with Mtwo, RaCe, K3, and/or Prodesign Logic instruments.

Abstract

Objectives: This study was conducted to evaluate and compare the tip and taper compatibility of accessory gutta-percha points (AGPs) with various rotary and reciprocating instruments. Materials and Methods: Using a profile analyzer, tip and taper measurements were taken of 10 AGPs of each of the 14 models available from Odous de Deus and the 4 models available from Dentsply-Maillefer. Diameter measurements were taken at 1-mm intervals, from 3 mm from the tip (D3) to 16 mm. Results: Based on the mean values obtained, 3-dimensional (3D) models of the AGPs were drawn in Autodesk Fusion 360 and superimposed on 3D models of each instrument selected (Mtwo, Reciproc, RaCe, K3, and ProDesign Logic) to determine the compatibility between the instrument and the AGP. Data corresponding to the tips and tapers of the various AGPs, as well as the tip and taper differences between the AGPs and the instruments, were analyzed using descriptive statistics. The tapers of the AGPs were subject to the American National Standards Institute/American Dental Association No. 57 standard. The Odous de Deus extra-long medium and extra-long extra-medium AGPs were shown to be compatible with Mtwo, K3, and ProDesign Logic instruments with taper 0.06 and tip sizes 25 and 30, while the Dentsply fine and fine medium cones were compatible with Mtwo, RaCe, and K3 instruments with conicity of 0.04 and tip sizes 35 and 40. Conclusions: Both the Odous de Deus and Dentsply commercial brands included 2 AGP models with tip (D3) and taper compatibility with Mtwo, RaCe, K3, and/or Prodesign Logic instruments.

참고문헌 (25)

  1. Ng YL, "Outcome of primary root canal treatment: systematic review of the literature -- Part 2. Influence of clinical factors", Int Endod J, 41, pp.6~31 (2008)
  2. Pedro FM, "Status of endodontic treatment and the correlations to the quality of root canal filling and coronal restoration", J Contemp Dent Pract, 17, pp.830~836 (2016)
  3. Tomson RM, "Contemporary obturation of the root canal system", Br Dent J, 216, pp.315~322 (2014)
  4. Vishwanath V, "Gutta-percha in endodontics-a comprehensive review of material science", J Conserv Dent, 22, pp.216~222 (2019)
  5. Ricucci D, "Apically extruded sealers : fate and influence on treatment outcome", J Endod, 42, pp.243~249 (2016)
  6. Patni PM, "Stereomicroscopic evaluation of sealing ability of four different root canal sealers-an in vitro study", J Clin Diagn Res, 10, pp.ZC37~ZC39 (2016)
  7. Marashdeh MQ, "Esterases affect the physical properties of materials used to seal the endodontic space", Dent Mater, 35, pp.1065~1072 (2019)
  8. Ørstavik D, "Dimensional change following setting of root canal sealer materials", Dent Mater, 17, pp.512~519 (2001)
  9. Schäfer E, "Percentage of gutta-percha-filled areas in canals instrumented with nickel-titanium systems and obturated with matching single cones", J Endod, 39, pp.924~928 (2013)
  10. Yürüker S, "Efficacy of combined use of different nickel-titanium files on removing root canal filling materials", J Endod, 42, pp.487~492 (2016)
  11. Coelho MS, "Safety assessment of two hybrid instrumentation techniques in a dental student endodontic clinic : a retrospective study", J Dent Educ, 81, pp.333~339 (2017)
  12. Council on Dental Materials, Instruments, and Equipment, "ANSI", ADA specification no. 57 for endodontic filling materials, 2022
  13. Haupt F, "Diameter and taper variability of single-file instrumentation systems and their corresponding gutta-percha cones", J Endod, 44, pp.1436~1441 (2018)
  14. Lask JT, "Variability of the diameter and taper of size #30, 0.04 nickel-titanium rotary files", J Endod, 32, pp.1171~1173 (2006)
  15. Holland R, "Factors affecting the periapical healing process of endodontically treated teeth", J Appl Oral Sci, 25, pp.465~476 (2017)
  16. Ersahan S, "Solubility and apical sealing characteristics of a new calcium silicate-based root canal sealer in comparison to calcium hydroxide-, methacrylate resin- and epoxy resin-based sealers", Acta Odontol Scand, 71, pp.857~862 (2013)
  17. Rosen E, "The prognosis of altered sensation after extrusion of root canal filling materials : a systematic review of the literature", J Endod, 42, pp.873~879 (2016)
  18. Ricucci D, "Wound healing of apical tissues after root canal therapy: a long-term clinical, radiographic, and histopathologic observation study", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 108, pp.609~621 (2009)
  19. Gordon MP, "An evaluation of .06 tapered gutta-percha cones for filling of .06 taper prepared curved root canals", Int Endod J, 38, pp.87~96 (2005)
  20. Almeida BM, "Matching the dimensions of currently available instruments with the apical diameters of mandibular molar mesial root canals obtained by micro-computed tomography", J Endod, 45, pp.756~760 (2019)
  21. Brunson M, "Effect of apical preparation size and preparation taper on irrigant volume delivered by using negative pressure irrigation system", J Endod, 36, pp.721~724 (2010)
  22. Keles A, "Evaluation of dentine thickness of middle mesial canals of mandibular molars prepared with rotary instruments : a micro-CT study", Int Endod J, 53, pp.519~528 (2020)
  23. Metzger Z, "Apical seal by customized versus standardized master cones : a comparative study in flat and round canals", J Endod, 14, pp.381~384 (1988)
  24. Silvestrin T, "Effect of apex size on the leakage of gutta-percha and sealer-filled root canals", Quintessence Int, 47, pp.373~378 (2016)
  25. "Specification No. 58. Root canal files, type H (Hedstrom)"[URL]

관련 논문AI추천

Comparison of the apical gutta-percha cone volume based on the gutta-percha gauging techniqueHee-Ra Lee, Ho-Keel Hwang, Hyoung-Hoon Jo, Jeong-Bum Min치의학연구원 · Oral Biology Research2025 · 제49권 제2호A comparison of dimensional standard of several nickel-titanium rotary files김기원, 김진우, 박세희, 조경모, 최기열, Bekir Karabucak대한치과보존학회 · Restorative Dentistry and Endodontics2014 · 제39권 제1호Shaping ability and apical debris extrusion after root canal preparation with rotary or reciprocating instruments: a micro-CT studyBarbosa Ana Flávia Almeida, da Silva Emmanuel João Nogueira Leal, de Lima Carolina Oliveira, de Moura Sara Gomes, Lacerda Mariane Floriano Lopes Santos, Misael Waleska Florentino, Sassone Luciana Moura대한치과보존학회 · Restorative Dentistry and Endodontics2021 · 제46권 제2호Efficacy of reciprocating and rotary retreatment nickel-titanium file systems for removing filling materials with a complementary cleaning method in oval canals김현철, Imane Benkiran, Lamyae Bedida, Said Dhaimy대한치과보존학회 · Restorative Dentistry and Endodontics2021 · 제46권 제1호Quantification of the tug-back by measuring the pulling force and micro computed tomographic evaluation문영미, 서민석, 전수진대한치과보존학회 · Restorative Dentistry and Endodontics2017 · 제42권 제4호Micro-computed tomographic assessment of the shaping ability of the One Curve, One Shape, and ProTaper Next nickel-titanium rotary systemsBilecenoglu Burak, Celikten Berkan, Gur Gurkan, Orhan Kaan, Sevimay Semra, Tufenkci Pelin대한치과보존학회 · Restorative Dentistry and Endodontics2020 · 제45권 제3호

이 간행물의 다른 논문 (9건)