본문 바로가기
KERD
논문KCI 등재

Evaluation of alveolar crest bone loss via premolar bitewing radiographs: presentation of a new method

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류치의학

초록

Purpose: This study aimed to assess the interdental bone level in premolar bitewing radiographswhile retracting the cheeks. Methods: Seventy-two horizontal bone defects were created on dried mandibles and maxillae. The distance from the bone level to the cement-enamel junction of premolars wasdetected by a modified digital caliper (considered the gold standard). The reliability of allradiographs was assessed by intraclass correlation coefficient (ICC), and the validity wascompared to the gold standard using the analysis of variance test. P-values less than 0.05were considered statistically significant. Results: This study showed that the reliability of radiographs without a cheek simulatorand with 0.16 second exposure time was significantly higher than that of the two othergroups (ICC=0.96 compared to 0.93 and 0.88, respectively). The results from the radiographswithout a cheek simulator and with 0.16 second exposure time were more similar tothe gold standard measures than those of the two other groups, although the differencewas not statistically significant. Conclusions: Retracting the buccal soft tissue plays an important role in increasing the accuracyof radiographs in detecting the interdental alveolar bone level and produces moreaccurate results than increasing the exposure time, although it does not have a significantrole in reliability of results.

Abstract

Purpose: This study aimed to assess the interdental bone level in premolar bitewing radiographswhile retracting the cheeks. Methods: Seventy-two horizontal bone defects were created on dried mandibles and maxillae. The distance from the bone level to the cement-enamel junction of premolars wasdetected by a modified digital caliper (considered the gold standard). The reliability of allradiographs was assessed by intraclass correlation coefficient (ICC), and the validity wascompared to the gold standard using the analysis of variance test. P-values less than 0.05were considered statistically significant. Results: This study showed that the reliability of radiographs without a cheek simulatorand with 0.16 second exposure time was significantly higher than that of the two othergroups (ICC=0.96 compared to 0.93 and 0.88, respectively). The results from the radiographswithout a cheek simulator and with 0.16 second exposure time were more similar tothe gold standard measures than those of the two other groups, although the differencewas not statistically significant. Conclusions: Retracting the buccal soft tissue plays an important role in increasing the accuracyof radiographs in detecting the interdental alveolar bone level and produces moreaccurate results than increasing the exposure time, although it does not have a significantrole in reliability of results.

참고문헌 (30)

  1. Novak MJ, "Carranza's clinical periodontology. 11th ed", pp.34~54 (2012), Elsevier Saunders Inc.
  2. Armitage GC, "Development of a classification system for periodontal diseases and conditions", Ann Periodontol, 4, pp.1~6 (1999)
  3. Flemmig TF, "Periodontitis", Ann Periodontol, 4, pp.32~38 (1999)
  4. Benn DK, "A review of the reliability of radiographic measurements in estimating alveolar bone changes", J Clin Periodontol, 17, pp.14~21 (1990)
  5. Pepelassi EA, "Selection of the most accurate method of conventional radiography for the assessment of periodontal osseous destruction", J Clin Periodontol, 24, pp.557~567 (1997)
  6. Kiliç AR, "A new method for standardization of intraoral radiographs", Periodontal Clin Investig, 18, pp.20~26 (1996)
  7. Gedik R, "Assessment of alveolar bone levels from bitewing, periapical and panoramic radiographs in periodontitis patients", West Indian Med J, 57, pp.410~413 (2008)
  8. Kim TS, "Detection of bone loss with different x-ray techniques in periodontal patients", J Periodontol, 79, pp.1141~1149 (2008)
  9. Pepelassi EA, "Radiographic detection and assessment of the periodontal endosseous defects", J Clin Periodontol, 27, pp.224~230 (2000)
  10. Vandenberghe B, "Diagnostic validity (or acuity) of 2D CCD versus 3D CBCT-images for assessing periodontal breakdown", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 104, pp.395~401 (2007)
  11. Eickholz P, "Digital radiography of interproximal bone loss; validity of different filters", J Clin Periodontol, 26, pp.294~300 (1999)
  12. Kim TS, "Accuracy of computer-assisted radiographic measurement of interproximal bone loss in vertical bone defects", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 94, pp.379~387 (2002)
  13. Tihanyi D, "Influence of individual brightness and contrast adjustment on accuracy of radiographic measurements of infrabony defects", Dentomaxillofac Radiol, 40, pp.177~183 (2011)
  14. Horwitz J, "Radiographic parameters as prognostic indicators for healing of class II furcation defects", J Clin Periodontol, 31, pp.105~111 (2004)
  15. Gomes-Filho IS, "Radiographic features of periodontal bone defects: evaluation of digitized images", Dentomaxillofac Radiol, 36, pp.256~262 (2007)
  16. Benn DK, "Frequent, low-dose, improved-contrast radiographic images with the use of narrow x-ray beams", Oral Surg Oral Med Oral Pathol, 74, pp.221~229 (1992)
  17. Bohay RN, "The sensitivity, specificity, and reliability of radiographic periapical diagnosis of posterior teeth", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 89, pp.639~642 (2000)
  18. Torres MG, "Assessment of enamel-dentin caries lesions detection using bitewing PSP digital images", J Appl Oral Sci, 19, pp.462~468 (2011)
  19. Fleiss JL, "The design and analysis of clinical experiments" (1986), Wiley
  20. Kay SM, "Fundamentals of statistical signal processing, Volume III: practical algorithm development" (2013), Prentice Hall
  21. Schropp L, "Validity of wax and acrylic as soft-tissue simulation materials used in in vitro radiographic studies", Dentomaxillofac Radiol, 41, pp.686~690 (2012)
  22. Feijo CV, "Evaluation of cone beam computed tomography in the detection of horizontal periodontal bone defects: an in vivo study", Int J Periodontics Restorative Dent, 32, pp.e162~e168 (2012)
  23. Zybutz M, "Comparisons of clinical and radiographic measurements of inter-proximal vertical defects before and 1 year after surgical treatments", J Clin Periodontol, 27, pp.179~186 (2000)
  24. Albandar JM, "Comparison between standardized periapical and bitewing radiographs in assessing alveolar bone loss", Community Dent Oral Epidemiol, 13, pp.222~225 (1985)
  25. Ordinola-Zapata R, "The influence of cone-beam computed tomography and periapical radiographic evaluation on the assessment of periapical bone destruction in dog's teeth", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 112, pp.272~279 (2011)
  26. de Faria Vasconcelos K, "Detection of periodontal bone loss using cone beam CT and intraoral radiography", Dentomaxillofac Radiol, 41, pp.64~69 (2012)
  27. Mohan R, "Three-dimensional imaging in periodontal diagnosis - Utilization of cone beam computed tomography", J Indian Soc Periodontol, 15, pp.11~17 (2011)
  28. Esmaeli F, "Determination of vertical interproximal bone loss topography: correlation between indirect digital radiographic measurement and clinical measurement", Iran J Radiol, 9, pp.83~87 (2012)
  29. Henriksson CH, "Comparison of the reproducibility of storage phosphor and film bitewings for assessment of alveolar bone los", Acta Odontol Scand, 66, pp.380~384 (2008)
  30. Wolf B, "Reliability of assessing interproximal bone loss by digital radiography: intrabony defects", J Clin Periodontol, 28, pp.869~878 (2001)

관련 논문AI추천

Accuracy of three-dimensional periodontal ligament models generated using cone-beam computed tomography at different resolutions for the assessment of periodontal bone lossHangmiao Lyu, Huimin Ma, Jianxia Hou, Li Xu, Weiran Li, Xiaotong Li, Xiaoxia Wang, Yijiao Zhao, Yong Wang대한치과교정학회 · 대한치과교정학회지2023 · 제53권 제2호Prediction of the alveolar bone level after the extraction of maxillary anterior teeth with severe periodontitis이주연, 주지영, 최점일, Chul Eui Hong대한치주과학회 · Journal of Periodontal & Implant Science2015 · 제45권 제6호구강 내 치근단 방사선 영상을 이용한 치조골 골밀도 측정의 유용성 평가김은석, 박은진, David-Hyungjin Kim대한치과보철학회 · 대한치과보철학회지2014 · 제52권 제3호New method of assessing the relationship between buccal bone thickness and gingival thickness구영, 구기태, 김성태, 김윤정, 류인철, 박지만, 설양조, 이용무대한치주과학회 · Journal of Periodontal & Implant Science2016 · 제46권 제6호Reliability of partial-mouth periodontal examinations for diagnosing periodontal diseaseBohee Kang, Bumhee Park, Geum Hee Choi, Heelim Lee, Hyelynn Jeon, Jae Suk Jung, Suk Ji, Sunjin Kim대한치주과학회 · Journal of Periodontal & Implant Science2025 · 제55권 제4호Soft Tissue Measurement Method Using Radiopaque Material on Cone-beam Computed Tomography: An Ex Vivo Validation Study윤정호, 이동원, 이해석대한구강악안면임플란트학회 · 대한구강악안면임플란트학회지2018 · 제22권 제4호

이 간행물의 다른 논문 (7건)