Surface characteristics of a novel hydroxyapatite-coated dental implant
0
조회
0
다운로드
4
인용
0
참고문헌
키워드
초록
Purpose: This study evaluated the surface characteristics and bond strength produced using a novel technique for coating hydroxyapatite (HA) onto titanium implants. Methods: HA was coated on the titanium implant surface using a super-high-speed (SHS) blasting method with highly purified HA. The coating was performed at a low temperature, unlike conventional HA coating methods. Coating thickness was measured. The novel HA-coated disc was fabricated. X-ray diffraction analysis was performed directly on the disc to evaluate crystallinity. Four novel HA-coated discs and four resorbable blast medium (RBM) discs were prepared. Their surface roughnesses and areas were measured. Five puretitanium, RBM-treated, and novel HA-coated discs were prepared. Contact angle was measured. Two-way analysis of variance and the post-hoc Scheffe’s test were used to analyze differences between the groups, with those with a probability of P<0.05 considered to be statistically significant. To evaluate exfoliation of the coating layer, 7 sites on the mandibles from 7 mongrel dogs were used. Other sites were used for another research project. In total,seven novel HA-coated implants were placed 2 months after extraction of premolars according to the manufacturer’s instructions. The dogs were sacrificed 8 weeks after implant surgery. Implants were removed using a ratchet driver. The surface of the retrieved implants was evaluated microscopically. Results: A uniform HA coating layer was formed on the titanium implants with no deformation of the RBM titanium surface microtexture when an SHS blasting method was used. Conclusions: These HA-coated implants exhibited increased roughness, crystallinity, and wettability when compared with RBM implants.
Abstract
Purpose: This study evaluated the surface characteristics and bond strength produced using a novel technique for coating hydroxyapatite (HA) onto titanium implants. Methods: HA was coated on the titanium implant surface using a super-high-speed (SHS) blasting method with highly purified HA. The coating was performed at a low temperature, unlike conventional HA coating methods. Coating thickness was measured. The novel HA-coated disc was fabricated. X-ray diffraction analysis was performed directly on the disc to evaluate crystallinity. Four novel HA-coated discs and four resorbable blast medium (RBM) discs were prepared. Their surface roughnesses and areas were measured. Five puretitanium, RBM-treated, and novel HA-coated discs were prepared. Contact angle was measured. Two-way analysis of variance and the post-hoc Scheffe’s test were used to analyze differences between the groups, with those with a probability of P<0.05 considered to be statistically significant. To evaluate exfoliation of the coating layer, 7 sites on the mandibles from 7 mongrel dogs were used. Other sites were used for another research project. In total,seven novel HA-coated implants were placed 2 months after extraction of premolars according to the manufacturer’s instructions. The dogs were sacrificed 8 weeks after implant surgery. Implants were removed using a ratchet driver. The surface of the retrieved implants was evaluated microscopically. Results: A uniform HA coating layer was formed on the titanium implants with no deformation of the RBM titanium surface microtexture when an SHS blasting method was used. Conclusions: These HA-coated implants exhibited increased roughness, crystallinity, and wettability when compared with RBM implants.
참고문헌 (27)
- Chaffee NR, "Fixed partial dentures combining both resin-bonded and conventional retainers: a clinical report", J Prosthet Dent, 83, pp.272~275 (2000)
- Shalabi MM, "Implant surface roughness and bone healing: a systematic review", J Dent Res, 85, pp.496~500 (2006)
- Wennerberg A, "Effects of titanium surface topography on bone integration: a systematic review", Clin Oral Implants Res, 20(4), pp.172~184 (2009)
- Wennerberg A, "On implant surfaces: a review of current knowledge and opinions", Int J Oral Maxillofac Implants, 25, pp.63~74 (2010)
- de Groot K, "Plasma sprayed coatings of hydroxylapatite", J Biomed Mater Res, 21, pp.1375~1381 (1987)
- Thomas KA, "The effect of surface macrotexture and hydroxylapatite coating on the mechanical strengths and histologic profiles of titanium implant materials", J Biomed Mater Res, 21, pp.1395~1414 (1987)
- Wang CY, "Comparison of biological characteristics of mesenchymal stem cells grown on two different titanium implant surfaces", Biomed Mater, 3, pp.015004~ (2008)
- Park YS, "The effects of ion beam-assisted deposition of hydroxyapatite on the grit-blasted surface of endosseous implants in rabbit tibiae", Int J Oral Maxillofac Implants, 20, pp.31~38 (2005)
- Gottlander M, "Histomorphometric studies of hydroxylapatite-coated and uncoated CP titanium threaded implants in bone", Int J Oral Maxillofac Implants, 6, pp.399~404 (1991)
- Ji H, "Effect of heat treatment on the microstructure of plasma-sprayed hydroxyapatite coating", Biomaterials, 14, pp.64~68 (1993)
- Zyman Z, "Amorphous phase and morphological structure of hydroxyapatite plasma coatings", Biomaterials, 14, pp.225~228 (1993)
- Chen J, "Microstructure and crystallinity in hydroxyapatite coatings", Biomaterials, 15, pp.396~399 (1994)
- Tsui YC, "Plasma sprayed hydroxyapatite coatings on titanium substrates. Part 2: optimisation of coating properties", Biomaterials, 19, pp.2031~2043 (1998)
- Biesbrock AR, "Evaluation of the clinical predictability of hydroxyapatite-coated endosseous dental implants: a review of the literature", Int J Oral Maxillofac Implants, 10, pp.712~720 (1995)
- Liao H, "Stability of hydroxyapatite-coatings on titanium oral implants (IMZ). 2 retrieved cases", Clin Oral Implants Res, 8, pp.68~72 (1997)
- Ong JL, "Structure, solubility and bond strength of thin calcium phosphate coatings produced by ion beam sputter deposition", Biomaterials, 13, pp.249~254 (1992)
- Yoshinari M, "Thin hydroxyapatite coating produced by the ion beam dynamic mixing method", Biomaterials, 15, pp.529~535 (1994)
- van Dijk K, "Influence of annealing temperature on RF magnetron sputtered calcium phosphate coatings", Biomaterials, 17, pp.405~410 (1996)
- Singh RK, "Excimer laser deposition of hydroxyapatite thin films", Biomaterials, 15, pp.522~528 (1994)
- Albrektsson T, "Oral implant surfaces: Part 1--review focusing on topographic and chemical properties of different surfaces and in vivo responses to them", Int J Prosthodont, 17, pp.536~543 (2004)
- Yang Y, "Osteoblast precursor cell attachment on heat-treated calcium phosphate coatings", J Dent Res, 82, pp.449~453 (2003)
- Katto M, "Crystallized hydroxyapatite coatings deposited by PLD with targets of different densities", J Phys: Conf Ser, 59, pp.75~78 (2007)
- Cleries L, "Dissolution behaviour of calcium phosphate coatings obtained by laser ablation", Biomaterials, 19, pp.1483~1487 (1998)
- Arias JL, "Physicochemical properties of calcium phosphate coatings produced by pulsed laser deposition at different water vapour pressures", Biomaterials, 19, pp.883~888 (1998)
- Rupp F, "Enhancing surface free energy and hydrophilicity through chemical modification of microstructured titanium implant surfaces", J Biomed Mater Res A, 76, pp.323~334 (2006)
- Buser D, "Enhanced bone apposition to a chemically modified SLA titanium surface", J Dent Res, 83, pp.529~533 (2004)
- Ferguson SJ, "Biomechanical evaluation of the interfacial strength of a chemically modified sandblasted and acid-etched titanium surface", J Biomed Mater Res A, 78, pp.291~297 (2006)