본문 바로가기
KERD
논문KCI 등재

Surface characteristics of a novel hydroxyapatite-coated dental implant

0

조회

0

다운로드

4

인용

0

참고문헌

키워드

주제분류치의학

초록

Purpose: This study evaluated the surface characteristics and bond strength produced using a novel technique for coating hydroxyapatite (HA) onto titanium implants. Methods: HA was coated on the titanium implant surface using a super-high-speed (SHS) blasting method with highly purified HA. The coating was performed at a low temperature, unlike conventional HA coating methods. Coating thickness was measured. The novel HA-coated disc was fabricated. X-ray diffraction analysis was performed directly on the disc to evaluate crystallinity. Four novel HA-coated discs and four resorbable blast medium (RBM) discs were prepared. Their surface roughnesses and areas were measured. Five puretitanium, RBM-treated, and novel HA-coated discs were prepared. Contact angle was measured. Two-way analysis of variance and the post-hoc Scheffe’s test were used to analyze differences between the groups, with those with a probability of P<0.05 considered to be statistically significant. To evaluate exfoliation of the coating layer, 7 sites on the mandibles from 7 mongrel dogs were used. Other sites were used for another research project. In total,seven novel HA-coated implants were placed 2 months after extraction of premolars according to the manufacturer’s instructions. The dogs were sacrificed 8 weeks after implant surgery. Implants were removed using a ratchet driver. The surface of the retrieved implants was evaluated microscopically. Results: A uniform HA coating layer was formed on the titanium implants with no deformation of the RBM titanium surface microtexture when an SHS blasting method was used. Conclusions: These HA-coated implants exhibited increased roughness, crystallinity, and wettability when compared with RBM implants.

Abstract

Purpose: This study evaluated the surface characteristics and bond strength produced using a novel technique for coating hydroxyapatite (HA) onto titanium implants. Methods: HA was coated on the titanium implant surface using a super-high-speed (SHS) blasting method with highly purified HA. The coating was performed at a low temperature, unlike conventional HA coating methods. Coating thickness was measured. The novel HA-coated disc was fabricated. X-ray diffraction analysis was performed directly on the disc to evaluate crystallinity. Four novel HA-coated discs and four resorbable blast medium (RBM) discs were prepared. Their surface roughnesses and areas were measured. Five puretitanium, RBM-treated, and novel HA-coated discs were prepared. Contact angle was measured. Two-way analysis of variance and the post-hoc Scheffe’s test were used to analyze differences between the groups, with those with a probability of P<0.05 considered to be statistically significant. To evaluate exfoliation of the coating layer, 7 sites on the mandibles from 7 mongrel dogs were used. Other sites were used for another research project. In total,seven novel HA-coated implants were placed 2 months after extraction of premolars according to the manufacturer’s instructions. The dogs were sacrificed 8 weeks after implant surgery. Implants were removed using a ratchet driver. The surface of the retrieved implants was evaluated microscopically. Results: A uniform HA coating layer was formed on the titanium implants with no deformation of the RBM titanium surface microtexture when an SHS blasting method was used. Conclusions: These HA-coated implants exhibited increased roughness, crystallinity, and wettability when compared with RBM implants.

참고문헌 (27)

  1. Chaffee NR, "Fixed partial dentures combining both resin-bonded and conventional retainers: a clinical report", J Prosthet Dent, 83, pp.272~275 (2000)
  2. Shalabi MM, "Implant surface roughness and bone healing: a systematic review", J Dent Res, 85, pp.496~500 (2006)
  3. Wennerberg A, "Effects of titanium surface topography on bone integration: a systematic review", Clin Oral Implants Res, 20(4), pp.172~184 (2009)
  4. Wennerberg A, "On implant surfaces: a review of current knowledge and opinions", Int J Oral Maxillofac Implants, 25, pp.63~74 (2010)
  5. de Groot K, "Plasma sprayed coatings of hydroxylapatite", J Biomed Mater Res, 21, pp.1375~1381 (1987)
  6. Thomas KA, "The effect of surface macrotexture and hydroxylapatite coating on the mechanical strengths and histologic profiles of titanium implant materials", J Biomed Mater Res, 21, pp.1395~1414 (1987)
  7. Wang CY, "Comparison of biological characteristics of mesenchymal stem cells grown on two different titanium implant surfaces", Biomed Mater, 3, pp.015004~ (2008)
  8. Park YS, "The effects of ion beam-assisted deposition of hydroxyapatite on the grit-blasted surface of endosseous implants in rabbit tibiae", Int J Oral Maxillofac Implants, 20, pp.31~38 (2005)
  9. Gottlander M, "Histomorphometric studies of hydroxylapatite-coated and uncoated CP titanium threaded implants in bone", Int J Oral Maxillofac Implants, 6, pp.399~404 (1991)
  10. Ji H, "Effect of heat treatment on the microstructure of plasma-sprayed hydroxyapatite coating", Biomaterials, 14, pp.64~68 (1993)
  11. Zyman Z, "Amorphous phase and morphological structure of hydroxyapatite plasma coatings", Biomaterials, 14, pp.225~228 (1993)
  12. Chen J, "Microstructure and crystallinity in hydroxyapatite coatings", Biomaterials, 15, pp.396~399 (1994)
  13. Tsui YC, "Plasma sprayed hydroxyapatite coatings on titanium substrates. Part 2: optimisation of coating properties", Biomaterials, 19, pp.2031~2043 (1998)
  14. Biesbrock AR, "Evaluation of the clinical predictability of hydroxyapatite-coated endosseous dental implants: a review of the literature", Int J Oral Maxillofac Implants, 10, pp.712~720 (1995)
  15. Liao H, "Stability of hydroxyapatite-coatings on titanium oral implants (IMZ). 2 retrieved cases", Clin Oral Implants Res, 8, pp.68~72 (1997)
  16. Ong JL, "Structure, solubility and bond strength of thin calcium phosphate coatings produced by ion beam sputter deposition", Biomaterials, 13, pp.249~254 (1992)
  17. Yoshinari M, "Thin hydroxyapatite coating produced by the ion beam dynamic mixing method", Biomaterials, 15, pp.529~535 (1994)
  18. van Dijk K, "Influence of annealing temperature on RF magnetron sputtered calcium phosphate coatings", Biomaterials, 17, pp.405~410 (1996)
  19. Singh RK, "Excimer laser deposition of hydroxyapatite thin films", Biomaterials, 15, pp.522~528 (1994)
  20. Albrektsson T, "Oral implant surfaces: Part 1--review focusing on topographic and chemical properties of different surfaces and in vivo responses to them", Int J Prosthodont, 17, pp.536~543 (2004)
  21. Yang Y, "Osteoblast precursor cell attachment on heat-treated calcium phosphate coatings", J Dent Res, 82, pp.449~453 (2003)
  22. Katto M, "Crystallized hydroxyapatite coatings deposited by PLD with targets of different densities", J Phys: Conf Ser, 59, pp.75~78 (2007)
  23. Cleries L, "Dissolution behaviour of calcium phosphate coatings obtained by laser ablation", Biomaterials, 19, pp.1483~1487 (1998)
  24. Arias JL, "Physicochemical properties of calcium phosphate coatings produced by pulsed laser deposition at different water vapour pressures", Biomaterials, 19, pp.883~888 (1998)
  25. Rupp F, "Enhancing surface free energy and hydrophilicity through chemical modification of microstructured titanium implant surfaces", J Biomed Mater Res A, 76, pp.323~334 (2006)
  26. Buser D, "Enhanced bone apposition to a chemically modified SLA titanium surface", J Dent Res, 83, pp.529~533 (2004)
  27. Ferguson SJ, "Biomechanical evaluation of the interfacial strength of a chemically modified sandblasted and acid-etched titanium surface", J Biomed Mater Res A, 78, pp.291~297 (2006)

관련 논문AI추천

Comparative study for osseointegration according to surface treatments of dental implants국민석, Myoung-Ju Kim, Myung Hyun Jun, You-Song Sim치의학연구원 · Oral Biology Research2020 · 제44권 제2호Dissolution behavior and early bone apposition of calcium phosphate-coated machined implants이은웅, 이인섭, 이중석, 정의원, 최성호, 황지완대한치주과학회 · Journal of Periodontal & Implant Science2013 · 제43권 제6호Comparative study on the osseointegration of implants in dog mandibles according to the implant surface treatment김수관, 오지수, 유재식, 윤욱재, 임성철, 정경인, 정미애대한구강악안면외과학회 · 대한구강악안면외과학회지2016 · 제42권 제6호The histometric analysis of osseointegration in hydroxyapatite surface dental implants by ion beam-assisted deposition김민경, 김성태, 김종관, 이인섭, 정의원, 조규성, 채경준, 최성호, 최정유대한치주과학회 · Journal of Periodontal & Implant Science2008 · 제38권 제2호The effects of Hydroxyapatite nano-coating implants on healing of surgically created circumferential gap in dogs김종관, 이인섭, 임현창, 정성민, 조규성, 채경준, 최성호, 최정유대한치주과학회 · Journal of Periodontal & Implant Science2008 · 제38권 제2호Histomorphometric evaluation for osseointegration after particulated-dentin coated implant placement김수관치의학연구원 · Oral Biology Research2015 · 제39권 제1호

이 간행물의 다른 논문 (5건)