Detection of root perforations using conventional and digital intraoral radiography, multidetector computed tomography and cone beam computed tomography
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Objectives: This study aimed to compare the accuracy of conventional intraoral (CI) radiography, photostimulable phosphor (PSP) radiography, cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) for detection of strip and root perforations in endodontically treated teeth. Materials and Methods: Mesial and distal roots of 72 recently extracted molar were endodontically prepared. Perforations were created in 0.2, 0.3, or 0.4 mm diameter around the furcation of 48 roots (strip perforation) and at the external surface of 48 roots (root perforation); 48 roots were not perforated (control group). After root obturation, intraoral radiography, CBCT and MDCT were taken. Discontinuity in the root structure was interpreted as perforation. Two observers examined the images. Data were analyzed using Stata software and Chi-square test. Results: The sensitivity and specificity of CI, PSP, CBCT and MDCT in detection of strip perforations were 81.25% and 93.75%, 85.42% and 91.67%, 97.92% and 85.42%, and 72.92% and 87.50%, respectively. For diagnosis of root perforation, the sensitivity and specificity were 87.50% and 93.75%, 89.58% and 91.67%, 97.92% and 85.42%, and 81.25% and 87.50%, respectively. For detection of strip perforation, the difference between CBCT and all other methods including CI, PSP and MDCT was significant (p < 0.05). For detection of root perforation, only the difference between CBCT and MDCT was significant, and for all the other methods no statistically significant difference was observed. Conclusions: If it is not possible to diagnose the root perforations by periapical radiographs, CBCT is the best radiographic technique while MDCT is not recommended.
Abstract
Objectives: This study aimed to compare the accuracy of conventional intraoral (CI) radiography, photostimulable phosphor (PSP) radiography, cone beam computed tomography (CBCT) and multidetector computed tomography (MDCT) for detection of strip and root perforations in endodontically treated teeth. Materials and Methods: Mesial and distal roots of 72 recently extracted molar were endodontically prepared. Perforations were created in 0.2, 0.3, or 0.4 mm diameter around the furcation of 48 roots (strip perforation) and at the external surface of 48 roots (root perforation); 48 roots were not perforated (control group). After root obturation, intraoral radiography, CBCT and MDCT were taken. Discontinuity in the root structure was interpreted as perforation. Two observers examined the images. Data were analyzed using Stata software and Chi-square test. Results: The sensitivity and specificity of CI, PSP, CBCT and MDCT in detection of strip perforations were 81.25% and 93.75%, 85.42% and 91.67%, 97.92% and 85.42%, and 72.92% and 87.50%, respectively. For diagnosis of root perforation, the sensitivity and specificity were 87.50% and 93.75%, 89.58% and 91.67%, 97.92% and 85.42%, and 81.25% and 87.50%, respectively. For detection of strip perforation, the difference between CBCT and all other methods including CI, PSP and MDCT was significant (p < 0.05). For detection of root perforation, only the difference between CBCT and MDCT was significant, and for all the other methods no statistically significant difference was observed. Conclusions: If it is not possible to diagnose the root perforations by periapical radiographs, CBCT is the best radiographic technique while MDCT is not recommended.
참고문헌 (39)
- Fuss Z, "Root perforations: classification and treatment choices based on prognostic factors", Endod Dent Traumatol, 12, pp.255~264 (1996)
- Ingle JI, "A standardized endodontic technique utilizing newly designed instruments and filling materials", Oral Surg Oral Med Oral Pathol, 14, pp.83~91 (1961)
- Tsesis I, "Diagnosis and treatment of accidental root perforations", Endod Topics, 13, pp.95~107 (2006)
- Alhadainy HA, "Root perforations. A review of literature", Oral Surg Oral Med Oral Pathol, 78, pp.368~374 (1994)
- Bryant ST, "Shaping ability of .04 and .06 taper ProFile rotary nickel-titanium instruments in stimulated root canals", Int Endod J, 32, pp.155~164 (1999)
- Berutti E, "Thickness of cementum", dentin in mesial roots of mandibular first molars, 1992, pp.18, 545~548
- Shemesh H, "The use of cone-beam computed tomography and digital periapical radiographs to diagnose root perforations", J Endod, 37, pp.513~516 (2011)
- Ball RL, "Intraoperative endodontic applications of cone-beam computed tomography", J Endod, 39, pp.548~557 (2013)
- Patel S, "Detection of periapical bone defects in human jaws using cone beam computed tomography and intraoral radiography", Int Endod J, 42, pp.507~515 (2009)
- Chindasombatjaroen J, "Quantitative analysis of metallic artifacts caused by dental metals: comparison of cone-beam and multi-detector row CT scanners", Oral Radiol, 27, pp.114~120 (2011)
- Gaia BF, "Comparison between cone-beam and multislice computed tomography for identification of simulated bone lesions", Braz Oral Res, 25, pp.362~368 (2011)
- Eskandarloo A, "Comparison of cone-beam computed tomography with intraoral photostimulable phosphor imaging plate for diagnosis of endodontic complications: a simulation study", Oral Surg Oral Med Oral Pathol Oral Radiol, 114, pp.e54~e61 (2012)
- Fuss Z, "Determination of location of root perforations by electronic apex locators", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 82, pp.324~329 (1996)
- Skidmore AE, "Root canal morphology of the human mandibular first molar", Oral Surg Oral Med Oral Pathol, 32, pp.778~784 (1971)
- Bender IB, "Roentgenographic and direct observation of experimental lesions in bone: I. 1961", J Endod, 29, pp.702~706 (2003)
- Farman AG, "A comparison of 18 different x-ray detectors currently used in dentistry", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 99, pp.485~489 (2005)
- Udupa H, "Evaluation of image quality parameters of representative intraoral digital radiographic systems", Oral Surg Oral Med Oral Pathol Oral Radiol, 116, pp.774~783 (2013)
- Li G, "Detection of in vitro proximal caries in storage phosphor plate radiographs scanned with different resolutions", Dentomaxillofac Radiol, 37, pp.325~329 (2008)
- Nair MK, "Digital and advanced imaging in endodontics: a review", J Endod, 33, pp.1~6 (2007)
- Naitoh M, "Comparison between cone-beam and multislice computed tomography depicting mandibular neurovascular canal structures", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 109, pp.e25~e31 (2010)
- Cheng JG, "Detection accuracy of proximal caries by phosphor plate and cone-beam computerized tomography images scanned with different resolutions", Clin Oral Investig, 16, pp.1015~1021 (2012)
- Spin-Neto R, "Impact of voxel size variation on CBCT-based diagnostic outcome in dentistry: a systematic review", J Digit Imaging, 26, pp.813~820 (2013)
- Haiter-Neto F, "Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions", Dentomaxillofac Radiol, 37, pp.18~22 (2008)
- D’Addazio PS, "A comparative study between cone beam computed tomography and periapical radiographs in diagnosis of simulated endodontic complications", Int Endod J, 44, pp.218~224 (2011)
- Hassan B, "Detection of vertical root fractures in endodontically treated teeth by a cone beam computed tomography scan", J Endod, 35, pp.719~722 (2009)
- Bueno MR, "Map-reading strategy to diagnose root perforations near metallic intracanal posts by using cone beam computed tomography", J Endod, 37, pp.85~90 (2011)
- Wilkinson T, "The correlation between sagittal anatomic sections and computerized tomography of the TMJ", J Craniomandibular Pract, 1, pp.37~45 (1983)
- Solar P, "Precision of three-dimensional CTassisted model production in the maxillofacial area", Eur Radiol, 2, pp.473~477 (1992)
- Casselman JW, "Computed tomography in the determination of anatomical landmarks in the perspective of endosseous oral implant installation", J Head Neck Pathol, 7, pp.255~264 (1988)
- Youssefzadeh S, "Dental Vertical Root Fractures: Value of CT in Detection", Radiology J, 210, pp.545~549 (1999)
- Iikubo M, "Accuracy of intraoral radiography, multidetector helical CT, and limited cone-beam CT for the detection of horizontal tooth root fracture", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 108, pp.e70~e74 (2009)
- Baxter BS, "Factors affecting the measurement of size and CT number in computed tomography", Invest Radiol, 16, pp.337~341 (1981)
- Shaha AR, "Preoperative evaluation of the mandible in patients with carcinoma of the floor of mouth", Head Neck, 13, pp.398~402 (1991)
- Fava LR, "Periapical radiographic techniques during endodontic diagnosis and treatment", Int Endod J, 30, pp.250~261 (1997)
- Venskutonis T, "Influence of voxel size on the diagnostic ability of cone-beam computed tomography to evaluate simulated root perforations", Oral Radiol, 29, pp.151~159 (2013)
- Hovland EJ, "Problems in the management of tooth resorption. Problem solving in endodontics", pp.253~276 (1997), CV Mosby
- Carvalho-Sousa B, "Filling lateral canals: evaluation of different filling techniques", Eur J Dent, 4, pp.251~256 (2010)
- Loubele M, "Comparison between effective radiation dose of CBCT and MDCT scanners for dentomaxillofacial applications", Eur J Radiol, 71, pp.461~468 (2009)
- Ludlow JB, "Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology", Oral Surg Oral Med Oral Pathol Oral Radiol Endod, 106, pp.106~114 (2008)
