The implementation of imaging methods that enable sensitive and specific observation of anatomical structures has been a constant in the evolution of endodontic therapy. Cone-beam computed tomography (CBCT) enables 3-dimensional (3D) spatial anatomical navigation in the 3 volumetric planes (sagittal, coronal and axial) which translates into great accuracy for the identification of endodontic pathologies/conditions. CBCT interpretation consists of 2 main components: (i) the generation of specific tasks of the image and (ii) the subsequent interpretation report. A systematic and reproducible method to review CBCT scans can improve the accuracy of the interpretation process, translating into greater precision in terms of diagnosis and planning of endodontic clinical procedures. MEDLINE (PubMed), Web of Science, Google Scholar, Embase and Scopus were searched from inception to March 2023. This narrative review addresses the theoretical concepts, elements of interpretation and applications of the CBCT scan in endodontics. In addition, the contents and rationale for reporting 3D endodontic imaging are discussed.

Abstract

The implementation of imaging methods that enable sensitive and specific observation of anatomical structures has been a constant in the evolution of endodontic therapy. Cone-beam computed tomography (CBCT) enables 3-dimensional (3D) spatial anatomical navigation in the 3 volumetric planes (sagittal, coronal and axial) which translates into great accuracy for the identification of endodontic pathologies/conditions. CBCT interpretation consists of 2 main components: (i) the generation of specific tasks of the image and (ii) the subsequent interpretation report. A systematic and reproducible method to review CBCT scans can improve the accuracy of the interpretation process, translating into greater precision in terms of diagnosis and planning of endodontic clinical procedures. MEDLINE (PubMed), Web of Science, Google Scholar, Embase and Scopus were searched from inception to March 2023. This narrative review addresses the theoretical concepts, elements of interpretation and applications of the CBCT scan in endodontics. In addition, the contents and rationale for reporting 3D endodontic imaging are discussed.

참고문헌 (59)

  1. Patel S, "New dimensions in endodontic imaging: part 1. conventional and alternative radiographic systems", Int Endod J, 42, pp.447~462 (2009)
  2. Jain S, "New evolution of cone-beam computed tomography in dentistry : combining digital technologies", Imaging Sci Dent, 49, pp.179~190 (2019)
  3. Patel S, "New dimensions in endodontic imaging : part 2. cone beam computed tomography", Int Endod J, 42, pp.463~475 (2009)
  4. Pauwels R, "Technical aspects of dental CBCT : state of the art", Dentomaxillofac Radiol, 44, pp.20140224~ (2015)
  5. Park JS, "A proposal of new reference system for the standard axial, sagittal, coronal planes of brain based on the serially-sectioned images", J Korean Med Sci, 25, pp.135~141 (2010)
  6. Uğur Aydin Z, "Determination of root canal length up to perforation area using different electronic apex locators and CBCT images obtained at different voxel sizes : a comparative ex vivo study", Chin J Dent Res, 24, pp.49~54 (2021)
  7. Scarfe WC, "White and Pharoah’s oral radiology: principles and interpretation", pp.386~414 (2014), Elsevier Health Sciences
  8. Brüllmann D, "Spatial resolution in CBCT machines for dental", maxillofacial applications-what do we know today?, 2015, pp.44, 20140204~
  9. Special Committee to Revise the Joint AAE, "AAOMR Position Statement on use of CBCT in Endodontics", AAE and AAOMR joint position statement : use of cone beam computed tomography in endodontics 2015 update, 2015, pp.120, 508~512
  10. Scarfe WC, "Use of cone beam computed tomography in endodontics", Int J Dent, 2009, pp.634567~ (2009)
  11. Metska ME, "Detection of vertical root fractures in vivo in endodontically treated teeth by cone-beam computed tomography scans", J Endod, 38, pp.1344~1347 (2012)
  12. Tanimoto H, "The effect of voxel size on image reconstruction in cone-beam computed tomography", Oral Radiol, 25, pp.149~153 (2009)
  13. Patel S, "European Society of Endodontology position statement : use of cone beam computed tomography in endodontics : European Society of Endodontology(ESE)developed by", Int Endod J, 52, pp.1675~1678 (2019)
  14. Sinha A, "Understanding artifacts in cone beam computed tomography", Int J Maxillofac Imaging, 2, pp.51~53 (2016)
  15. Pinto JC, "Image quality for visualization of cracks and fine endodontic structures using 10 CBCT devices with various scanning protocols and artefact conditions", Sci Rep, 13, pp.4001~ (2023)
  16. Zhu J, "An update on the diagnosis and treatment of dens invaginatus", Aust Dent J, 62, pp.261~275 (2017)
  17. Da Silveira PF, "CBCT-based volume of simulated root resorption-influence of FOV and voxel size", Int Endod J, 48, pp.959~965 (2015)
  18. Pérez-Sánchez G, "Vestibular alveolar bone height measurement : accuracy and correlation between direct and indirect techniques", Acta Odontol Latinoam, 33, pp.22~26 (2020)
  19. Strbac GD, "Guided modern endodontic surgery : a novel approach for guided osteotomy and root resection", J Endod, 43, pp.496~501 (2017)
  20. Mayo CV Jr, "Accuracy of presurgical limited field of view cone-beam computed tomography in predicting intraoperative buccal cortical bone", J Endod, 46, pp.169~177 (2020)
  21. Antal M, "Digitally planned root end surgery with static guide and custom trephine burs : a case report", Int J Med Robot, 16, pp.e2115~ (2020)
  22. Bechara B, "Number of basis images effect on detection of root fractures in endodontically treated teeth using a cone beam computed tomography machine : an in vitro study", Oral Surg Oral Med Oral Pathol Oral Radiol, 115, pp.676~681 (2013)
  23. ICRP, "Radiological protection in cone beam computed tomography(CBCT). ICRP publication 129", Ann ICRP, 44, pp.9~127 (2015)
  24. Kadesjö N, "Radiation dose from X-ray examinations of impacted canines : cone beam CT vs two-dimensional imaging", Dentomaxillofac Radiol, 47, pp.20170305~ (2018)
  25. Ludlow JB, "Effective dose of dental CBCT-a meta analysis of published data and additional data for nine CBCT units", Dentomaxillofac Radiol, 44, pp.20140197~ (2015)
  26. Patel S, "Cone beam computed tomography in endodontics-a review of the literature", Int Endod J, 52, pp.1138~1152 (2019)
  27. Candemil AP, "Cone beam CT optimisation for detection of vertical root fracture with metal in the field of view or the exomass", Sci Rep, 11, pp.19155~ (2021)
  28. Van Acker JW, "Outcomes of different radioprotective precautions in children undergoing dental radiography : a systematic review", Eur Arch Paediatr Dent, 21, pp.463~508 (2020)
  29. Gamache C, "Assessment of image quality in maxillofacial cone-beam computed tomography imaging", Semin Orthod, 21, pp.248~253 (2015)
  30. Soares MR, "Study of effective dose of various protocols in equipment cone beam CT", Appl Radiat Isot, 100, pp.21~26 (2015)
  31. Lagos de Melo LP, "Influence of acquisition parameters on the evaluation of mandibular third molars through cone beam computed tomography", Oral Surg Oral Med Oral Pathol Oral Radiol, 124, pp.183~190 (2017)
  32. Goulston R, "Dose optimization by altering the operating potential and tube current exposure time product in dental cone beam CT : a systematic review", Dentomaxillofac Radiol, 45, pp.20150254~ (2016)
  33. Scarfe WC, "Maxillofacial cone beam computed tomography : essence, elements and steps to interpretation", Aust Dent J, 57(Supplement 1), pp.46~60 (2012)
  34. Durack C, "Cone beam computed tomography in endodontics", Braz Dent J, 23, pp.179~191 (2012)
  35. Hoff MN, "Can cephalometric parameters be measured reproducibly using reduced-dose cone-beam computed tomography?", J World Fed Orthod, 8, pp.43~50 (2019)
  36. Dillenseger JP, "Image quality evaluation of small FOV and large FOV CBCT devices for oral and maxillofacial radiology", Dentomaxillofac Radiol, 46, pp.20160285~ (2017)
  37. Uysal S, "The influence of voxel size and artifact reduction on the detection of vertical root fracture in endodontically treated teeth", Acta Odontol Scand, 79, pp.354~358 (2021)
  38. Liedke GS, "Influence of voxel size in the diagnostic ability of cone beam tomography to evaluate simulated external root resorption", J Endod, 35, pp.233~235 (2009)
  39. BashizadehFakhar H, "Diagnostic accuracy of cone-beam computed tomography at different tube voltages for vertical root fractures in endodontically treated teeth with metallic posts", Dent Hypotheses, 12, pp.132~138 (2021)
  40. Bechara B, "Evaluation of a cone beam CT artefact reduction algorithm", Dentomaxillofac Radiol, 41, pp.422~428 (2012)
  41. Bagis N, "Evaluation of a metal artifact reduction algorithm and an adaptive image noise optimization filter in the estimation of peri-implant fenestration defects using cone beam computed tomography : an in-vitro study", Oral Radiol, 38, pp.325~335 (2022)
  42. Nascimento MC, "Influence of cone beam CT enhancement filters on diagnosis ability of longitudinal root fractures", Dentomaxillofac Radiol, 43, pp.20130374~ (2014)
  43. Verner FS, "Influence of cone-beam computed tomography filters on diagnosis of simulated endodontic complications", Int Endod J, 50, pp.1089~1096 (2017)
  44. Xia D, "Backprojection-filtration reconstruction without invoking a spatially varying weighting factor", Med Phys, 37, pp.1201~1209 (2010)
  45. Patel S, "Guidelines for reporting on CBCT scans", Int Endod J, 54, pp.628~633 (2021)
  46. Moshfeghi M, "Effect of slice thickness on the accuracy of linear measurements made on cone beam computed tomography images", J Dent Sch, 34, pp.100~108 (2019)
  47. Pham VK, "Root canal length estimated by cone-beam computed tomography at different slice thicknesses, dedicated endodontic software, or measured by an electronic apex locator", Sci Rep, 12, pp.6531~ (2022)
  48. Moudi E, "Assessment of vertical root fracture using cone-beam computed tomography", Imaging Sci Dent, 44, pp.37~41 (2014)
  49. Patel S, "The detection of vertical root fractures in root filled teeth with periapical radiographs and CBCT scans", Int Endod J, 46, pp.1140~1152 (2013)
  50. Scarfe WC, "What is cone-beam CT and how does it work?", Dent Clin North Am, 52, pp.707~730 (2008)
  51. Martins JN, "Differences on the root and root canal morphologies between Asian and White ethnic groups analyzed by cone-beam computed tomography", J Endod, 44, pp.1096~1104 (2018)
  52. European Society of Radiology(ESR), "Good practice for radiological reporting. Guidelines from the European Society of Radiology(ESR)", Insights Imaging, 2, pp.93~96 (2011)
  53. Schulze R, "Artefacts in CBCT : a review", Dentomaxillofac Radiol, 40, pp.265~273 (2011)
  54. Bidgood WD Jr, "Understanding and using DICOM, the data interchange standard for biomedical imaging", J Am Med Inform Assoc, 4, pp.199~212 (1997)
  55. Rodrigues CT, "Influence of CBCT-based volumetric distortion and beam hardening artefacts on the assessment of root canal filling quality in isthmus-containing molars", Dentomaxillofac Radiol, 50, pp.20200503~ (2021)
  56. Gregoris Rabelo LE, "Blooming artifact reduction using different cone-beam computed tomography software to analyze endodontically treated teeth with intracanal posts", Comput Biol Med, 136, pp.104679~ (2021)
  57. Spin-Neto R, "Exploring CBCT-based DICOM files. A systematic review on the properties of images used to evaluate maxillofacial bone grafts", J Digit Imaging, 24, pp.959~966 (2011)
  58. Varma DR, "Managing DICOM images : tips and tricks for the radiologist", Indian J Radiol Imaging, 22, pp.4~13 (2012)
  59. Gibaud B, "Molecular imaging: computer reconstruction and practice", pp.229~238 (2008), Springer

관련 논문AI추천

근관치료 영역에서 Cone Beam CT의 활용조형훈대한치과의사협회 · 대한치과의사협회지2019 · 제57권 제7호Procedural errors detected by cone beam tomography in cases with indication for retreatment: in vivo cross-sectional studyAlves Flávio R. F., Rupaya Carmen Rosa Garcia, Valverde Haro Henry Paul대한치과보존학회 · Restorative Dentistry and Endodontics2024 · 제49권 제3호How protocol, posts, and experience affect fracture detection in multi-rooted teeth using cone-beam computed tomography: an ex vivo experimental studyde Abreu Gabriela Marzullo, de Mello Wislem Miranda, Liedke Gabriela Salatino, Maracci Lucas Machado, Savegnago Gleica Dal’ Ongaro, Spiger Carolina Baumgratz대한치과보존학회 · Restorative Dentistry and Endodontics2025 · 제50권 제3호Use of cone-beam computed tomography and three-dimensional modeling for assessment of anomalous pulp canal configuration: a case reportAlper Sinanoglu, Dilek Helvacioglu-Yigit, Ibrahim Mutlu대한치과보존학회 · Restorative Dentistry and Endodontics2015 · 제40권 제2호Influence of CBCT parameters on image quality and the diagnosis of vertical root fractures in teeth with metallic posts: an ex vivo studyFreitas Deborah Queiroz, Lagos de Melo Larissa Pereira, Moreira-Souza Larissa, Nadaes Mariana Rocha, Oliveira Matheus Lima, Queiroz Polyane Mazucatto, Santaella Gustavo Machado대한치과보존학회 · Restorative Dentistry and Endodontics2023 · 제48권 제2호Which factors related to apical radiolucency may influence its radiographic detection? A study using CBCT as reference standardCardelli Laís Oliveira de Araujo, Fontenele Rocharles Cavalcante, Freitas Deborah Queiroz, Gaêta-Araujo Hugo, Nascimento Eduarda Helena Leandro대한치과보존학회 · Restorative Dentistry and Endodontics2021 · 제46권 제3호

이 간행물의 다른 논문 (10건)