Influence of CBCT parameters on image quality and the diagnosis of vertical root fractures in teeth with metallic posts: an ex vivo study
1
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Objectives: The aim of this study was to evaluate the influence of peak kilovoltage (kVp) and a metal artifact reduction (MAR) tool on image quality and the diagnosis of vertical root fracture (VRF) in cone-beam computed tomography (CBCT). Materials and Methods: Twenty single-rooted human teeth filled with an intracanal metal post were divided into 2 groups: control (n = 10) and VRF (n = 10). Each tooth was placed into the socket of a dry mandible, and CBCT scans were acquired using a Picasso Trio varying the kVp (70, 80, 90, or 99), and the use of MAR (with or without). The examinations were assessed by 5 examiners for the diagnosis of VRF using a 5-point scale. A subjective evaluation of the expression of artifacts was done by comparing random axial images of the studied protocols. The results of the diagnoses were analyzed using 2-way analysis of variance and the Tukey post hoc test, the subjective evaluations were compared using the Friedman test, and intra-examiner reproducibility was evaluated using the weighted kappa test (α = 5%). Results: The kVp and MAR did not influence the diagnosis of VRF (p > 0.05). According to the subjective classification, the 99 kVp protocol with MAR demonstrated the least expression of artifacts, while the 70 kVp protocol without MAR led to the most artifacts. Conclusions: Protocols with higher kVp combined with MAR improved the image quality of CBCT examinations. However, those factors did not lead to an improvement in the diagnosis of VRF.
Abstract
Objectives: The aim of this study was to evaluate the influence of peak kilovoltage (kVp) and a metal artifact reduction (MAR) tool on image quality and the diagnosis of vertical root fracture (VRF) in cone-beam computed tomography (CBCT). Materials and Methods: Twenty single-rooted human teeth filled with an intracanal metal post were divided into 2 groups: control (n = 10) and VRF (n = 10). Each tooth was placed into the socket of a dry mandible, and CBCT scans were acquired using a Picasso Trio varying the kVp (70, 80, 90, or 99), and the use of MAR (with or without). The examinations were assessed by 5 examiners for the diagnosis of VRF using a 5-point scale. A subjective evaluation of the expression of artifacts was done by comparing random axial images of the studied protocols. The results of the diagnoses were analyzed using 2-way analysis of variance and the Tukey post hoc test, the subjective evaluations were compared using the Friedman test, and intra-examiner reproducibility was evaluated using the weighted kappa test (α = 5%). Results: The kVp and MAR did not influence the diagnosis of VRF (p > 0.05). According to the subjective classification, the 99 kVp protocol with MAR demonstrated the least expression of artifacts, while the 70 kVp protocol without MAR led to the most artifacts. Conclusions: Protocols with higher kVp combined with MAR improved the image quality of CBCT examinations. However, those factors did not lead to an improvement in the diagnosis of VRF.
참고문헌 (29)
- Ferreira LM, "Influence of CBCT enhancement filters on diagnosis of vertical root fractures : a simulation study in endodontically treated teeth with and without intracanal posts", Dentomaxillofac Radiol, 44, pp.20140352~ (2015)
- Fernanda Paula Yamamoto-Silva, "Influence of voxel size on cone-beam computed tomography-based detection of vertical root fractures in the presence of intracanal metallic posts", Imaging Science in Dentistry, 48(3), pp.177~184 (2018), 대한영상치의학회
- Chang E, "Cone-beam computed tomography for detecting vertical root fractures in endodontically treated teeth : a systematic review", J Endod, 42, pp.177~185 (2016)
- Freitas DQ, "Diagnosis of vertical root fracture in teeth close and distant to implant : an in vitro study to assess the influence of artifacts produced in cone beam computed tomography", Clin Oral Investig, 23, pp.1263~1270 (2019)
- Schulze R, "Artefacts in CBCT : a review", Dentomaxillofac Radiol, 40, pp.265~273 (2011)
- Queiroz PM, "Evaluation of metal artefact reduction in cone-beam computed tomography images of different dental materials", Clin Oral Investig, 22, pp.419~423 (2018)
- Bechara BB, "Metal artefact reduction with cone beam CT : an in vitro study", Dentomaxillofac Radiol, 41, pp.248~253 (2012)
- Helvacioglu-Yigit D, "Evaluation and reduction of artifacts generated by 4 different root-end filling materials by using multiple cone-beam computed tomography imaging settings", J Endod, 42, pp.307~314 (2016)
- Bezerra IS, "Influence of the artefact reduction algorithm of Picasso Trio CBCT system on the diagnosis of vertical root fractures in teeth with metal posts", Dentomaxillofac Radiol, 44, pp.20140428~ (2015)
- Bechara B, "Cone beam CT scans with and without artefact reduction in root fracture detection of endodontically treated teeth", Dentomaxillofac Radiol, 42, pp.20120245~ (2013)
- de Rezende Barbosa GL, "Performance of an artefact reduction algorithm in the diagnosis of in vitro vertical root fracture in four different root filling conditions on CBCT images", Int Endod J, 49, pp.500~508 (2016)
- Pauwels R, "Technical aspects of dental CBCT : state of the art", Dentomaxillofac Radiol, 44, pp.20140224~ (2015)
- Freitas DQ, "Influence of acquisition parameters on the magnitude of cone beam computed tomography artifacts", Dentomaxillofac Radiol, 47, pp.20180151~ (2018)
- Oliveira ML, "Influence of exposure factors on the variability of CBCT voxel values : a phantom study", Dentomaxillofac Radiol, 43, pp.20140128~ (2014)
- Vasconcelos TV, "Evaluation of artifacts generated by zirconium implants in cone-beam computed tomography images", Oral Surg Oral Med Oral Pathol Oral Radiol, 123, pp.265~272 (2017)
- Landis JR, "The measurement of observer agreement for categorical data", Biometrics, 33, pp.159~174 (1977)
- Hassan B, "Comparison of five cone beam computed tomography systems for the detection of vertical root fractures", J Endod, 36, pp.126~129 (2010)
- Neves FS, "Evaluation of cone-beam computed tomography in the diagnosis of vertical root fractures : the influence of imaging modes and root canal materials", J Endod, 40, pp.1530~1536 (2014)
- Pinto MG, "Influence of exposure parameters on the detection of simulated root fractures in the presence of various intracanal materials", Int Endod J, 50, pp.586~594 (2017)
- Gaêta-Araujo H, "Optimization of tube current in cone-beam computed tomography for the detection of vertical root fractures with different intracanal materials", J Endod, 43, pp.1668~1673 (2017)
- Gaêta-Araujo H, "Cone beam computed tomography in dentomaxillofacial radiology : a two-decade overview", Dentomaxillofac Radiol, 49, pp.20200145~ (2020)
- Codari M, "Quantitative evaluation of metal artifacts using different CBCT devices, high-density materials and field of views", Clin Oral Implants Res, 28, pp.1509~1514 (2017)
- Brady E, "A comparison of cone beam computed tomography and periapical radiography for the detection of vertical root fractures in nonendodontically treated teeth", Int Endod J, 47, pp.735~746 (2014)
- Makeeva IM, "Detection of artificially induced vertical root fractures of different widths by cone beam computed tomography in vitro and in vivo", Int Endod J, 49, pp.980~989 (2016)
- Zhang L, "In vivo detection of subtle vertical root fracture in endodontically treated teeth by cone-beam computed tomography", J Endod, 45, pp.856~862 (2019)
- Bechara B, "Evaluation of a cone beam CT artefact reduction algorithm", Dentomaxillofac Radiol, 41, pp.422~428 (2012)
- Dalili Kajan Z, "The efficacy of metal artifact reduction mode in cone-beam computed tomography images on diagnostic accuracy of root fractures in teeth with intracanal posts", Iran Endod J, 13, pp.47~53 (2018)
- Special Committee to Revise the Joint AAE, "AAOMR Position Statement on use of CBCT in Endodontics", AAE and AAOMR joint position statement: use of cone beam computed tomography in endodontics 2015 update, 2015, pp.120, 508~512
- Patel S, "European Society of Endodontology position statement : use of cone beam computed tomography in Endodontics : European Society of Endodontology(ESE)developed by", Int Endod J, 52, pp.1675~1678 (2019)
