본문 바로가기
KERD
논문KCI 등재

Improved accuracy in periodontal pocket depth measurement using optical coherence tomography

2

조회

0

다운로드

2

인용

0

참고문헌

키워드

주제분류치의학

초록

Purpose: The purpose of this study was to examine whether periodontal pocket could be satisfactorily visualized by optical coherence tomography (OCT) and to suggest quantitative methods for measuring periodontal pocket depth. Methods: We acquired OCT images of periodontal pockets in a porcine model and determined the actual axial resolution for measuring the exact periodontal pocket depth using a calibration method. Quantitative measurements of periodontal pockets were performed by real axial resolution and compared with the results from manual periodontal probing. Results: The average periodontal pocket depth measured by OCT was 3.10±0.15 mm, 4.11±0.17 mm, 5.09±0.17 mm, and 6.05±0.21 mm for each periodontal pocket model, respectively. These values were similar to those obtained by manual periodontal probing. Conclusions: OCT was able to visualize periodontal pockets and show attachment loss. By calculating the calibration factor to determine the accurate axial resolution, quantitative standards for measuring periodontal pocket depth can be established regardless of the position of periodontal pocket in the OCT image.

Abstract

Purpose: The purpose of this study was to examine whether periodontal pocket could be satisfactorily visualized by optical coherence tomography (OCT) and to suggest quantitative methods for measuring periodontal pocket depth. Methods: We acquired OCT images of periodontal pockets in a porcine model and determined the actual axial resolution for measuring the exact periodontal pocket depth using a calibration method. Quantitative measurements of periodontal pockets were performed by real axial resolution and compared with the results from manual periodontal probing. Results: The average periodontal pocket depth measured by OCT was 3.10±0.15 mm, 4.11±0.17 mm, 5.09±0.17 mm, and 6.05±0.21 mm for each periodontal pocket model, respectively. These values were similar to those obtained by manual periodontal probing. Conclusions: OCT was able to visualize periodontal pockets and show attachment loss. By calculating the calibration factor to determine the accurate axial resolution, quantitative standards for measuring periodontal pocket depth can be established regardless of the position of periodontal pocket in the OCT image.

참고문헌 (32)

  1. Mota CC, "Non-invasive periodontal probing through fourier-domain optical coherence tomography", J Periodontol, 86, pp.1087~1094 (2015)
  2. Huang D, "Optical coherence tomography", Science, 254, pp.1178~1181 (1991)
  3. Adhi M, "Optical coherence tomography--current and future applications", Curr Opin Ophthalmol, 24, pp.213~221 (2013)
  4. Sattler E, "Optical coherence tomography in dermatology", J Biomed Opt, 18, pp.061224~ (2013)
  5. Kirtane TS, "Endoscopic optical coherence tomography(OCT) : advances in gastrointestinal imaging", Gastroenterol Res Pract, 2014, pp.376367~ (2014)
  6. Ferrante G, "Current applications of optical coherence tomography for coronary intervention", Int J Cardiol, 165, pp.7~16 (2013)
  7. Cheng HM, "Systematic review of optical coherence tomography usage in the diagnosis and management of basal cell carcinoma", Br J Dermatol, 173, pp.1371~1380 (2015)
  8. Colston BW Jr, "Imaging of hard-and soft-tissue structure in the oral cavity by optical coherence tomography", Appl Opt, 37, pp.3582~3585 (1998)
  9. Feldchtein F, "In vivo OCT imaging of hard and soft tissue of the oral cavity", Opt Express, 3, pp.239~250 (1998)
  10. Imai K, "Noninvasive cross-sectional visualization of enamel cracks by optical coherence tomography in vitro", J Endod, 38, pp.1269~1274 (2012)
  11. Ishibashi K, "Swept-source optical coherence tomography as a new tool to evaluate defects of resin-based composite restorations", J Dent, 39, pp.543~548 (2011)
  12. Shimada Y, "Validation of swept-source optical coherence tomography(SS-OCT)for the diagnosis of occlusal caries", J Dent, 38, pp.655~665 (2010)
  13. Di Stasio D, "In vivo characterization of oral pemphigus vulgaris by optical coherence tomography", J Biol Regul Homeost Agents, 29, pp.39~41 (2015)
  14. Tsai MT, "Differentiating oral lesions in different carcinogenesis stages with optical coherence tomography", J Biomed Opt, 14, pp.044028~ (2009)
  15. Hsieh YS, "Subgingival calculus imaging based on swept-source optical coherence tomography", J Biomed Opt, 16, pp.071409~ (2011)
  16. Kao MC, "Miniature endoscopic optical coherence tomography for calculus detection", Appl Opt, 54, pp.7419~7423 (2015)
  17. Baek JH, "Optical approach to the periodontal ligament under orthodontic tooth movement : a preliminary study with optical coherence tomography", Am J Orthod Dentofacial Orthop, 135, pp.252~259 (2009)
  18. Fernandes LO, "In vivo assessment of periodontal structures and measurement of gingival sulcus with optical coherence tomography: a pilot study", J Biophotonics (2016)
  19. Agrawal P, "New developments in tools for periodontal diagnosis", Int Dent J, 62, pp.57~64 (2012)
  20. Fujimoto JG, "Optical coherence tomography for ultrahigh resolution in vivo imaging", Nat Biotechnol, 21, pp.1361~1367 (2003)
  21. Armitage GC, "Clinical evaluation of periodontal diseases", Periodontol 2000, 7, pp.39~53 (1995)
  22. Savage A, "A systematic review of definitions of periodontitis and methods that have been used to identify this disease", J Clin Periodontol, 36, pp.458~467 (2009)
  23. Xiang X, "An update on novel non-invasive approaches for periodontal diagnosis", J Periodontol, 81, pp.186~198 (2010)
  24. Kao RT, "Thick vs. thin gingival tissue: a key determinant in tissue response to disease and restorative treatment", J Calif Dent Assoc, 30, pp.521~526 (2002)
  25. Thoma DS, "Critical soft-tissue dimensions with dental implants and treatment concepts", Periodontol 2000, 66, pp.106~118 (2014)
  26. Lee A, "Soft tissue biotype affects implant success", Implant Dent, 20, pp.e38~e47 (2011)
  27. Grossi SG, "Sources of error for periodontal probing measurements", J Periodontal Res, 31, pp.330~336 (1996)
  28. van der Velden U, "The influence of probing force on the reproducibility of pocket depth measurements", J Clin Periodontol, 7, pp.414~420 (1980)
  29. Badersten A, "Reproducibility of probing attachment level measurements", J Clin Periodontol, 11, pp.475~485 (1984)
  30. Watts TL., "Probing site configuration in patients with untreated periodontitis. A study of horizontal positional error", J Clin Periodontol, 16, pp.529~533 (1989)
  31. Hsieh YS, "Dental optical coherence tomography", Sensors(Basel), 13, pp.8928~8949 (2013)
  32. Goodson JM, "The relationship between attachment level loss and alveolar bone loss", J Clin Periodontol, 11, pp.348~359 (1984)

관련 논문AI추천

이 간행물의 다른 논문 (6건)